Command Line Interface Guide
Page 19
clear logging file 406 aaa logging 407 file-system logging 407 management logging 408 show logging 409 show logging file 411 show syslog-servers 412 31 System Management 415 ping 415 traceroute 417 telnet 420 resume 423 reload 423 hostname 424 service cpu-utilization 425 stack master 425 stack reload 426 show stack 427 show users 428 show sessions 429 show system 430 show version 431 asset-tag 432 show system id 433 show cpu utilization 434 Contents 19
clear logging file 406 aaa logging 407 file-system logging 407 management logging 408 show logging 409 show logging file 411 show syslog-servers 412 31 System Management 415 ping 415 traceroute 417 telnet 420 resume 423 reload 423 hostname 424 service cpu-utilization 425 stack master 425 stack reload 426 show stack 427 show users 428 show sessions 429 show system 430 show version 431 asset-tag 432 show system id 433 show cpu utilization 434 Contents 19
Command Line Interface Guide
Page 54
... Configuration Privileged EXEC Privileged EXEC Privileged EXEC System Management Commands Command Group ping traceroute telnet resume reload hostname stack master stack reload show stack show syslog-servers Changes the number of logging and the syslog messages stored in the internal buffer. Logs.... Clears messages from the internal logging buffer. Enables logging AAA login events. Displays the state of a stack master. Displays information about stack status. Access Mode User EXEC User EXEC User EXEC User EXEC Privileged EXEC Global Configuration Global Configuration Privileged ...
... Configuration Privileged EXEC Privileged EXEC Privileged EXEC System Management Commands Command Group ping traceroute telnet resume reload hostname stack master stack reload show stack show syslog-servers Changes the number of logging and the syslog messages stored in the internal buffer. Logs.... Clears messages from the internal logging buffer. Enables logging AAA login events. Displays the state of a stack master. Displays information about stack status. Access Mode User EXEC User EXEC User EXEC User EXEC Privileged EXEC Global Configuration Global Configuration Privileged ...
Command Line Interface Guide
Page 68
... mode spanning-tree mst configuration spanning-tree mst max-hops spanning-tree priority spanning-tree pathcost method spanning-tree priority stack master tacacs-server host tacacs-server key tacacs-server source-ip tacacs-server timeout username vlan database wrr-queue cos-...) Mode Command Group back-pressure bridge multicast forbidden forward-all bridge multicast forward-all Multicast port. Configures the forwarding state of a stack master. Configures the Spanning Tree bridge Hello Time. Enters the VLAN database configuration mode. Maps CoS values to a specific egress queue...
... mode spanning-tree mst configuration spanning-tree mst max-hops spanning-tree priority spanning-tree pathcost method spanning-tree priority stack master tacacs-server host tacacs-server key tacacs-server source-ip tacacs-server timeout username vlan database wrr-queue cos-...) Mode Command Group back-pressure bridge multicast forbidden forward-all bridge multicast forward-all Multicast port. Configures the forwarding state of a stack master. Configures the Spanning Tree bridge Hello Time. Enters the VLAN database configuration mode. Maps CoS values to a specific egress queue...
Command Line Interface Guide
Page 76
...Simple Network Time Protocol (SNTP). Displays configuration and statistics for a TACACS+ servers. Displays information about the local user database. Reloads stack members. Displays the configuration of users. Displays Spanning Tree configuration. Displays information about the login history of SNMP users. Diagnoses with TDR... users accounts show users login-history show vlan show vlan internal usage show vlan mac-to-vlan show vlan protocols-groups stack reload test copper-port tdr Displays the configuration of SNMP views. Displays the configuration of SNMP filters. UE (User EXEC...
...Simple Network Time Protocol (SNTP). Displays configuration and statistics for a TACACS+ servers. Displays information about the local user database. Reloads stack members. Displays the configuration of users. Displays Spanning Tree configuration. Displays information about the login history of SNMP users. Diagnoses with TDR... users accounts show users login-history show vlan show vlan internal usage show vlan mac-to-vlan show vlan protocols-groups stack reload test copper-port tdr Displays the configuration of SNMP views. Displays the configuration of SNMP filters. UE (User EXEC...
Command Line Interface Guide
Page 78
... host-time-out. ip igmp snooping leave-time-out Configures the leave-time-out. Displays RMON Ethernet Statistics. Displays information about stack status. Displays the system version information. Configures the command history buffer size for the current terminal session. bridge multicast forward-all ...all Forbids a port from becoming a forward-all Multicast frames on a port. show rmon log show rmon statistics show sessions show stack show system show system id show users show command without prompting. Sends ICMP echo request packets to the bridge table. Enables the command...
... host-time-out. ip igmp snooping leave-time-out Configures the leave-time-out. Displays RMON Ethernet Statistics. Displays information about stack status. Displays the system version information. Configures the command history buffer size for the current terminal session. bridge multicast forward-all ...all Forbids a port from becoming a forward-all Multicast frames on a port. show rmon log show rmon statistics show sessions show stack show system show system id show users show command without prompting. Sends ICMP echo request packets to the bridge table. Enables the command...
Command Line Interface Guide
Page 342
set to 3 to indicate the MAC address that the stack engine ID is unique throughout the entire management network. • Changing the value of the engine ID has the following is recommended: - For a stackable system, ... engineID local Global Configuration mode command. 342 SNMP Commands User Guidelines • To use the default keyword to specify an engine ID for the entire stack, and verify that follows. • Last 6 octets - first bit = 1, the rest is not configured. Command Mode Global Configuration mode. By default, SNMPv1/v2 are enabled...
set to 3 to indicate the MAC address that the stack engine ID is unique throughout the entire management network. • Changing the value of the engine ID has the following is recommended: - For a stackable system, ... engineID local Global Configuration mode command. 342 SNMP Commands User Guidelines • To use the default keyword to specify an engine ID for the entire stack, and verify that follows. • Last 6 octets - first bit = 1, the rest is not configured. Command Mode Global Configuration mode. By default, SNMPv1/v2 are enabled...
Command Line Interface Guide
Page 425
...Console(config)# hostname Dell Dell(config)# service cpu-utilization The service cpu-utilization global configuration mode command allows the software to measure CPU utilization. Use the no form of this command to disable measuring. Syntax • service cpu-utilization • no stack master •... User Guidelines There are no form of this command to return to the default configuration. console(config)# service cpu-utilization stack master The stack master Global Configuration mode command enables forcing the selection of the new master (Range: 1 - 2) System Management 425...
...Console(config)# hostname Dell Dell(config)# service cpu-utilization The service cpu-utilization global configuration mode command allows the software to measure CPU utilization. Use the no form of this command to disable measuring. Syntax • service cpu-utilization • no stack master •... User Guidelines There are no form of this command to return to the default configuration. console(config)# service cpu-utilization stack master The stack master Global Configuration mode command enables forcing the selection of the new master (Range: 1 - 2) System Management 425...
Command Line Interface Guide
Page 426
...forced master, it becomes the master. - If both are considered to have the same up within ten minutes of each other. - Syntax • stack reload [unit] • unit - User Guidelines If no unit is specified, all units are considered to be reloaded (Range: 1 - 8) ...Default Configuration All units are reloaded. Console(config)# stack master unit 2 stack reload The stack reload Privileged EXEC mode command reloads stack members. If only one master-enabled unit is in a different stack with the longer up-time is elected. Units are reloaded. 426 System...
...forced master, it becomes the master. - If both are considered to have the same up within ten minutes of each other. - Syntax • stack reload [unit] • unit - User Guidelines If no unit is specified, all units are considered to be reloaded (Range: 1 - 8) ...Default Configuration All units are reloaded. Console(config)# stack master unit 2 stack reload The stack reload Privileged EXEC mode command reloads stack members. If only one master-enabled unit is in a different stack with the longer up-time is elected. Units are reloaded. 426 System...
Command Line Interface Guide
Page 427
Example The following example reloads Unit 2 of the stack. Syntax • show stack Unit MAC Address Software Master Uplink Downlink Status 1 00:33:97:02:16:00 1.0.0.7 Forced 8 2 Master 2 00:33:97:02:21:00 ...Disabled 7 1 Slave System Management 427 Command Mode User EXEC mode. Console> show stack [unit unit] • unit - Specifies the number of a stack. User Guidelines There are no default configuration. Console(config)# stack reload unit 2 show stack The show stack User EXEC mode command displays information about the status of the unit. (Range: 1...
Example The following example reloads Unit 2 of the stack. Syntax • show stack Unit MAC Address Software Master Uplink Downlink Status 1 00:33:97:02:16:00 1.0.0.7 Forced 8 2 Master 2 00:33:97:02:21:00 ...Disabled 7 1 Slave System Management 427 Command Mode User EXEC mode. Console> show stack [unit unit] • unit - Specifies the number of a stack. User Guidelines There are no default configuration. Console(config)# stack reload unit 2 show stack The show stack User EXEC mode command displays information about the status of the unit. (Range: 1...
User's Guide
Page 3
Contents 1 Introduction 11 System Description 11 PowerConnect 3524 11 PowerConnect 3524P 11 PowerConnect 3548 12 PowerConnect 3548P 12 Stacking Overview 12 Understanding the Stack Topology 13 Stacking Failover Topology 13 Stacking Members and Unit ID 13 Removing and Replacing Stacking Members 14 Exchanging Stacking Members 15 Switching from the Stack Master to the Backup Stack Master 17 Features Overview 17 IP Version 6 (IPv6) Support...
Contents 1 Introduction 11 System Description 11 PowerConnect 3524 11 PowerConnect 3524P 11 PowerConnect 3548 12 PowerConnect 3548P 12 Stacking Overview 12 Understanding the Stack Topology 13 Stacking Failover Topology 13 Stacking Members and Unit ID 13 Removing and Replacing Stacking Members 14 Exchanging Stacking Members 15 Switching from the Stack Master to the Backup Stack Master 17 Features Overview 17 IP Version 6 (IPv6) Support...
User's Guide
Page 4
... Console Port 29 Physical Dimensions 30 LED Definitions 30 Gigabit Port LEDs 32 System LEDs 33 Power Supplies 35 Stack ID Button 36 Reset Button 37 Ventilation System 37 3 Installing the PowerConnect 3524/P and PowerConnect 3548/P 39 Site Preparation 39 Unpacking 39 Package Contents 39 Unpacking the Device 40 Mounting the Device 40 Installing...
... Console Port 29 Physical Dimensions 30 LED Definitions 30 Gigabit Port LEDs 32 System LEDs 33 Power Supplies 35 Stack ID Button 36 Reset Button 37 Ventilation System 37 3 Installing the PowerConnect 3524/P and PowerConnect 3548/P 39 Site Preparation 39 Unpacking 39 Package Contents 39 Unpacking the Device 40 Mounting the Device 40 Installing...
User's Guide
Page 6
... Asset Information 78 Asset 78 Defining System Time Settings 84 Viewing System Health Information 90 Managing Power over Ethernet 92 Viewing Version Information 98 Managing Stack Members 99 Resetting the Device 100 Configuring SNTP Settings 101 Defining SNTP Global Settings 103 Defining SNTP Authentication Methods 105 Defining SNTP Servers 107 Defining...
... Asset Information 78 Asset 78 Defining System Time Settings 84 Viewing System Health Information 90 Managing Power over Ethernet 92 Viewing Version Information 98 Managing Stack Members 99 Resetting the Device 100 Configuring SNTP Settings 101 Defining SNTP Global Settings 103 Defining SNTP Authentication Methods 105 Defining SNTP Servers 107 Defining...
User's Guide
Page 11
.... The PowerConnect 3524P is stacked. This User Guide contains the information needed for installing, configuring, and maintaining the device. Figure 1-1. Introduction Dell™ PowerConnect™ 3524/3548 and PowerConnect 3524P/3548P are stackable, advanced multi-layer devices. PowerConnect units can be used to eight stacking members. The device also provides one RS-232 console port. PowerConnect 3524 and PowerConnect 3524P Introduction...
.... The PowerConnect 3524P is stacked. This User Guide contains the information needed for installing, configuring, and maintaining the device. Figure 1-1. Introduction Dell™ PowerConnect™ 3524/3548 and PowerConnect 3524P/3548P are stackable, advanced multi-layer devices. PowerConnect units can be used to eight stacking members. The device also provides one RS-232 console port. PowerConnect 3524 and PowerConnect 3524P Introduction...
User's Guide
Page 12
... can operate as the Backup Master. Switch software is maintained by the Stack Master. In addition, PowerConnect 3548P provides PoE. PowerConnect 3548 and PowerConnect 3548P Stacking Overview PowerConnect 3524/P and PowerConnect 3548/P stacking provides multiple switch management through which can be running the same software version. PowerConnect 3548P The PowerConnect 3548P provides 48 10/100Mbps ports, two SFP ports, and two...
... can operate as the Backup Master. Switch software is maintained by the Stack Master. In addition, PowerConnect 3548P provides PoE. PowerConnect 3548 and PowerConnect 3548P Stacking Overview PowerConnect 3524/P and PowerConnect 3548/P stacking provides multiple switch management through which can be running the same software version. PowerConnect 3548P The PowerConnect 3548P provides 48 10/100Mbps ports, two SFP ports, and two...
User's Guide
Page 13
... becomes non-functional, or a link is restored. After the stacking issues are connected to the stack without any system downtime. Understanding the Stack Topology The PowerConnect 35xx series systems operates in a chain formation. With the PowerConnect 3524/P and PowerConnect 3548/P stack, the system automatically switches to ensure the stacking integrity. The system discovers the optimal path on which it...
... becomes non-functional, or a link is restored. After the stacking issues are connected to the stack without any system downtime. Understanding the Stack Topology The PowerConnect 35xx series systems operates in a chain formation. With the PowerConnect 3524/P and PowerConnect 3548/P stack, the system automatically switches to ensure the stacking integrity. The system discovers the optimal path on which it...
User's Guide
Page 14
... is elected as Backup Master, according to 8 can be the same age. Unit IDs 3 to the following decision process: • If only one Stack Master enabled unit is present, it is not erased, and remains valid, even if the unit is performed during the configuration process. For example, Unit ... up -time is operating as Master Unit or Backup Master Unit. NOTE: If two members are discovered with the same Unit ID the stack continues to join the stack. During the Warm Standby, the Master and the Backup Master are synchronized with a default Unit ID of the same cycle, the units ...
... is elected as Backup Master, according to 8 can be the same age. Unit IDs 3 to the following decision process: • If only one Stack Master enabled unit is present, it is not erased, and remains valid, even if the unit is performed during the configuration process. For example, Unit ... up -time is operating as Master Unit or Backup Master Unit. NOTE: If two members are discovered with the same Unit ID the stack continues to join the stack. During the Warm Standby, the Master and the Backup Master are synchronized with a default Unit ID of the same cycle, the units ...
User's Guide
Page 15
... are saved in the unit and are changed only through topology discovery. For example, • If a PowerConnect 3524/P replaces PowerConnect 3524/P, all port configurations remain the same. • If a PowerConnect 3548/P replaces the PowerConnect 3548/P, all units in the stack. Configuration files are learned through explicit user configuration. Configuration files are no longer present. Non-present ports...
... are saved in the unit and are changed only through topology discovery. For example, • If a PowerConnect 3524/P replaces PowerConnect 3524/P, all port configurations remain the same. • If a PowerConnect 3548/P replaces the PowerConnect 3548/P, all units in the stack. Configuration files are learned through explicit user configuration. Configuration files are no longer present. Non-present ports...
User's Guide
Page 17
...be used in a pure IPv6 network as well as dual stack). PowerConnect 3548/P port replaces PowerConect 3524/P Port Same Configuration Same Configuration Switching from the Stack Master to the Backup Stack Master The Backup Master replaces the Stack Master if the following applications: • IP Phones •...operation in the following events occur: • The Stack Master fails or is removed from the stack. • Links from the Stack Master to the stacking members fails. • A soft switchover is synchronized between the Stack Master and the Backup Master results in a combined ...
...be used in a pure IPv6 network as well as dual stack). PowerConnect 3548/P port replaces PowerConect 3524/P Port Same Configuration Same Configuration Switching from the Stack Master to the Backup Stack Master The Backup Master replaces the Stack Master if the following applications: • IP Phones •...operation in the following events occur: • The Stack Master fails or is removed from the stack. • Links from the Stack Master to the stacking members fails. • A soft switchover is synchronized between the Stack Master and the Backup Master results in a combined ...
User's Guide
Page 27
...stacking ports, or used as 10/100Base-T ports • 2 Fiber ports - Designated as 1000Base-T ports • Console port - RS-232 based port The following ports: • 24 Fast Ethernet ports - Hardware Description Port Description PowerConnect 3524 Port Description The Dell™ PowerConnect™ 3524... device is marked with the following figure illustrates the PowerConnect 3524 front panel. Designated as 1000Base-X SFP ports •...
...stacking ports, or used as 10/100Base-T ports • 2 Fiber ports - Designated as 1000Base-T ports • Console port - RS-232 based port The following ports: • 24 Fast Ethernet ports - Hardware Description Port Description PowerConnect 3524 Port Description The Dell™ PowerConnect™ 3524... device is marked with the following figure illustrates the PowerConnect 3524 front panel. Designated as 1000Base-X SFP ports •...
User's Guide
Page 28
... is the Reset Button which is used to select the unit number. RS-232 Console based port The following figure illustrates the PowerConnect 3524 back: Figure 2-2. PowerConnect 3548 Front Panel 10/100 Base-T Ports 1, 3, 5, 7, ...47 System LEDs Reset Button Stacking Button Stacking LEDs 10/100 Base-T Ports 2, 4, 6, 8, ...48 G1 G2 1000Base-X SFP Ports G3 G4...
... is the Reset Button which is used to select the unit number. RS-232 Console based port The following figure illustrates the PowerConnect 3524 back: Figure 2-2. PowerConnect 3548 Front Panel 10/100 Base-T Ports 1, 3, 5, 7, ...47 System LEDs Reset Button Stacking Button Stacking LEDs 10/100 Base-T Ports 2, 4, 6, 8, ...48 G1 G2 1000Base-X SFP Ports G3 G4...