Implementing Microsoft Windows Server 2003 with Service Pack 1 on ProLiant servers integration note
Page 14
... drivers, management agents, and utilities supported under Windows Server 2003. The following Hot Plug RAID Memory driver and utility are included in Version 7.30A and later of the ProLiant Support Pack for Microsoft Windows Server 2003: • HP ProLiant Hot-Plug Memory Configuration Utility for Windows Server 2003 • HP ProLiant Hot Plug Memory Driver for Windows Server 2003 Lights-Out management support Lights-Out management products, such as Integrated Lights-Out 2 (iLO 2), Integrated Lights-Out (iLO), and Remote Insight Lights-Out Edition II (RILOE II), remain an important part...
... drivers, management agents, and utilities supported under Windows Server 2003. The following Hot Plug RAID Memory driver and utility are included in Version 7.30A and later of the ProLiant Support Pack for Microsoft Windows Server 2003: • HP ProLiant Hot-Plug Memory Configuration Utility for Windows Server 2003 • HP ProLiant Hot Plug Memory Driver for Windows Server 2003 Lights-Out management support Lights-Out management products, such as Integrated Lights-Out 2 (iLO 2), Integrated Lights-Out (iLO), and Remote Insight Lights-Out Edition II (RILOE II), remain an important part...
Implementing Microsoft Windows Server 2003 with Service Pack 1 on ProLiant servers integration note
Page 17
... Windows Server 2003 Version 7.30A 5. For the PSP to use the functionality of the ProLiant Management Agents. • Select the Control Panel from the Start menu. • Select Add/Remove Programs. • Click Add/Remove Windows Components. • Select Management and Monitoring Tools from a command line prompt without user interaction. As with the SETUP.EXE program, all software components are selected for installation by default, only those required by accessing the Option ROM Configuration for installation. 4. If the server...
... Windows Server 2003 Version 7.30A 5. For the PSP to use the functionality of the ProLiant Management Agents. • Select the Control Panel from the Start menu. • Select Add/Remove Programs. • Click Add/Remove Windows Components. • Select Management and Monitoring Tools from a command line prompt without user interaction. As with the SETUP.EXE program, all software components are selected for installation by default, only those required by accessing the Option ROM Configuration for installation. 4. If the server...
Implementing Microsoft Windows Server 2003 with Service Pack 1 on ProLiant servers integration note
Page 20
...: Setup had problems installing the following device: Compaq Smart Array 4200 Controller. Upgrading miniport driver for a device containing dynamic disks, the software fault tolerant volumes located on these dynamic disks will fail and will not be fixed in insertion and removal events. Solution Scheduled to delay installing this time. Smart Array Cluster Controller Firmware Version 1.70 (or later) is updated for secondary device requires reboot. Workaround Reboot the server as follows: • Name: Online ROM Flash Component for Windows - Description When using Smart...
...: Setup had problems installing the following device: Compaq Smart Array 4200 Controller. Upgrading miniport driver for a device containing dynamic disks, the software fault tolerant volumes located on these dynamic disks will fail and will not be fixed in insertion and removal events. Solution Scheduled to delay installing this time. Smart Array Cluster Controller Firmware Version 1.70 (or later) is updated for secondary device requires reboot. Workaround Reboot the server as follows: • Name: Online ROM Flash Component for Windows - Description When using Smart...
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 13
... installs to abort with the downloaded files and the ProLiant Support Pack and Deployment Utilities User Guide posted on unattended installs, refer to the CD-ROM drive, upon a reboot of R2 specific components that may not be installed. The drivers for Microsoft Windows Server 2003 R2, which is complete, the utility will display successfully installed components, non-applicable components, and any special hardware-specific drivers appropriate for installation by default, only those required by the server will install. Part 2: Install Windows Server...
... installs to abort with the downloaded files and the ProLiant Support Pack and Deployment Utilities User Guide posted on unattended installs, refer to the CD-ROM drive, upon a reboot of R2 specific components that may not be installed. The drivers for Microsoft Windows Server 2003 R2, which is complete, the utility will display successfully installed components, non-applicable components, and any special hardware-specific drivers appropriate for installation by default, only those required by the server will install. Part 2: Install Windows Server...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 11
... boot controller. c. d. e. a. Accept the NetWare 6.5 and Report Runtime license agreements. The Default installation automatically detects drivers and installs the server with SCSI controllers do not support ORCA, and should be replaced. Inspect the system to either Default or Manual as the installation type. Power on the server. This setting will appear prompting you to confirm that it meets the minimum RAM and disk space requirements needed for the server. Choose option "I " (Install) or "R" (Run...
... boot controller. c. d. e. a. Accept the NetWare 6.5 and Report Runtime license agreements. The Default installation automatically detects drivers and installs the server with SCSI controllers do not support ORCA, and should be replaced. Inspect the system to either Default or Manual as the installation type. Power on the server. This setting will appear prompting you to confirm that it meets the minimum RAM and disk space requirements needed for the server. Choose option "I " (Install) or "R" (Run...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... CDs: SmartStart, Management, and ProLiant Firmware Maintenance. • HP is bootable only on server configuration and OS installation. Configure the array controller hardware using RBSU (ROM-Based Setup Utility) by booting SmartStart. RBSU and ACU (Array Configuration Utility) can also be liable for Arrays) or the Adaptec RAID Configuration Utility as constituting an additional warranty. Keep Software Up-to initiate and complete the operating system installation. Download the latest Management CD from www.hp.com/servers/manage • Download the latest...
... CDs: SmartStart, Management, and ProLiant Firmware Maintenance. • HP is bootable only on server configuration and OS installation. Configure the array controller hardware using RBSU (ROM-Based Setup Utility) by booting SmartStart. RBSU and ACU (Array Configuration Utility) can also be liable for Arrays) or the Adaptec RAID Configuration Utility as constituting an additional warranty. Keep Software Up-to initiate and complete the operating system installation. Download the latest Management CD from www.hp.com/servers/manage • Download the latest...
HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer
Page 4
... systems, the system BIOS, SCSI drivers, disk array drivers, the Windows Hardware Abstraction Layer (HAL), the Windows Registry, and the health driver. Typical uses of the Insight Diagnostics Online Edition include: • Gathering critical hardware and operating system configuration information which allows the administrator to analyze and troubleshoot an active or downed server. • Documenting server configurations for upgrade planning, standardization, inventory tracking, disaster recovery, and maintenance. • Comparing historical configurations on demand Fulfilling...
... systems, the system BIOS, SCSI drivers, disk array drivers, the Windows Hardware Abstraction Layer (HAL), the Windows Registry, and the health driver. Typical uses of the Insight Diagnostics Online Edition include: • Gathering critical hardware and operating system configuration information which allows the administrator to analyze and troubleshoot an active or downed server. • Documenting server configurations for upgrade planning, standardization, inventory tracking, disaster recovery, and maintenance. • Comparing historical configurations on demand Fulfilling...
Implementing Microsoft Windows 2000 with Service Pack 4 on ProLiant servers integration note
Page 28
... ProLiant Storage System hardware device (SCSI backplane) needs the HP driver to a HP server, the ATI driver cannot locate the video controller if the ATI Rage IIC video controller is not in the first slot. For multiple monitor installations, the ATI video controller should be in Windows 2000 failing to identify the drive and displaying this error message: Solution "Unsafe Removal of a SmartStart unattended installation. HP driver updates after hot-plugging a hard drive, Windows 2000 might inappropriately display an Unsafe Removal of Device prompt Description After hot...
... ProLiant Storage System hardware device (SCSI backplane) needs the HP driver to a HP server, the ATI driver cannot locate the video controller if the ATI Rage IIC video controller is not in the first slot. For multiple monitor installations, the ATI video controller should be in Windows 2000 failing to identify the drive and displaying this error message: Solution "Unsafe Removal of a SmartStart unattended installation. HP driver updates after hot-plugging a hard drive, Windows 2000 might inappropriately display an Unsafe Removal of Device prompt Description After hot...
Implementing Microsoft Windows Server 2003 with Service Pack 2 on HP ProLiant servers
Page 34
... port number and port ID in removal and insertion events are not enumerated consistently. Description After installing and configuring embedded network interface controllers (NICs) post Windows Server 2003 installation, the port configurations may not operate as follows: • Name: ProLiant Smart Array 5x and 6x Controller Driver for Windows Compaq Smart Array Cluster Storage Controller • Download location: www.hp.com/cgibin/hpsupport/index.pl CPQCISSE.SYS Version 5.42.2.32 (or later) is set as the boot controller. If you want to delay installing this issue, upgrade...
... port number and port ID in removal and insertion events are not enumerated consistently. Description After installing and configuring embedded network interface controllers (NICs) post Windows Server 2003 installation, the port configurations may not operate as follows: • Name: ProLiant Smart Array 5x and 6x Controller Driver for Windows Compaq Smart Array Cluster Storage Controller • Download location: www.hp.com/cgibin/hpsupport/index.pl CPQCISSE.SYS Version 5.42.2.32 (or later) is set as the boot controller. If you want to delay installing this issue, upgrade...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 23
... servers booting from Internal 4/8 Port SAS Controller, upgrading from the systems by certain storage applications for certain storage adapters or NICs. Workaround Remove lsicsb6.sys from Windows Server 2003 to hang. Workaround Update the ROM to set in the device manager for individual logical volumes, these polices are not saved when the device manager is for the controller and not for logical volumes on Windows Server 2008 x64 edition. Appendix A: known issues and workarounds ProLiant servers...
... servers booting from Internal 4/8 Port SAS Controller, upgrading from the systems by certain storage applications for certain storage adapters or NICs. Workaround Remove lsicsb6.sys from Windows Server 2003 to hang. Workaround Update the ROM to set in the device manager for individual logical volumes, these polices are not saved when the device manager is for the controller and not for logical volumes on Windows Server 2008 x64 edition. Appendix A: known issues and workarounds ProLiant servers...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 7
... and tested bundle that the following conditions are met: The server selected for installation, ensure that includes setup and software maintenance tools designed to help efficiently install, upgrade, and manage system software. PSP makes software maintenance easier by: • Increasing server manageability • Enabling administrators to configure the RAID settings for ProLiant servers HP recommends using SmartStart 8.25 or later. The HP ProLiant Support Pack for Microsoft Windows Server 2008 Foundation Version 8.25 is supported with Windows Server...
... and tested bundle that the following conditions are met: The server selected for installation, ensure that includes setup and software maintenance tools designed to help efficiently install, upgrade, and manage system software. PSP makes software maintenance easier by: • Increasing server manageability • Enabling administrators to configure the RAID settings for ProLiant servers HP recommends using SmartStart 8.25 or later. The HP ProLiant Support Pack for Microsoft Windows Server 2008 Foundation Version 8.25 is supported with Windows Server...
Compaq ProLiant CL380 Software User Guide
Page 15
... to the Compaq ProLiant CL380 User Guide. 2. NOTE: Compaq recommends that you create a 100-MB quorum drive to configure the shared drives during the server node 1 setup. Close Disk Administrator and restart Windows NT Server 4.0, Enterprise Edition. 24. Refer to access the KVM (Keyboard/Video/Mouse) switch and choose server node 2 from the list. Press Print Screen to MSCS documentation for installation steps. 25. Boot server node 2 with the SmartStart and Support Software CD in...
... to the Compaq ProLiant CL380 User Guide. 2. NOTE: Compaq recommends that you create a 100-MB quorum drive to configure the shared drives during the server node 1 setup. Close Disk Administrator and restart Windows NT Server 4.0, Enterprise Edition. 24. Refer to access the KVM (Keyboard/Video/Mouse) switch and choose server node 2 from the list. Press Print Screen to MSCS documentation for installation steps. 25. Boot server node 2 with the SmartStart and Support Software CD in...
Compaq ProLiant CL380 Software User Guide
Page 17
... settings for installation steps. 22. The system reboots. At the Enterprise Edition Installer, install Microsoft Cluster Server. Continue to view the Error Log. You will appear. View the log by the service pack, rerun the Server Support Software. At the end of the installation process. 16. Log on Yes. When configuring server node 2, the CR3500 Configuration Utility shows the results of both network adapters in the ProLiant CL380 in the Compaq ProLiant CL380. To ensure that the latest Compaq drivers...
... settings for installation steps. 22. The system reboots. At the Enterprise Edition Installer, install Microsoft Cluster Server. Continue to view the Error Log. You will appear. View the log by the service pack, rerun the Server Support Software. At the end of the installation process. 16. Log on Yes. When configuring server node 2, the CR3500 Configuration Utility shows the results of both network adapters in the ProLiant CL380 in the Compaq ProLiant CL380. To ensure that the latest Compaq drivers...
Compaq ProLiant CL380 Software User Guide
Page 20
... detected adapter (Intel 82557 based 10/100 Ethernet PCI Adapter) and install the correct network adapter (Compaq Ethernet or Fast Ethernet NIC adapters) from the Compaq Server Support for Microsoft Windows NT 4.0 diskette that will display a default list of the operating system. The files necessary to install the correct network adapter are instructed to insert the device support diskette provided by the Compaq Server Support for Microsoft Windows NT Server 4.0, Enterprise Edition 1-9 17. Insert the Compaq Server Support for Microsoft Windows NT 4.0 set of Windows...
... detected adapter (Intel 82557 based 10/100 Ethernet PCI Adapter) and install the correct network adapter (Compaq Ethernet or Fast Ethernet NIC adapters) from the Compaq Server Support for Microsoft Windows NT 4.0 diskette that will display a default list of the operating system. The files necessary to install the correct network adapter are instructed to insert the device support diskette provided by the Compaq Server Support for Microsoft Windows NT Server 4.0, Enterprise Edition 1-9 17. Insert the Compaq Server Support for Microsoft Windows NT 4.0 set of Windows...
Compaq ProLiant CL380 Software User Guide
Page 21
.... 1-10 Compaq ProLiant CL380 Software User Guide 25. NOTE: Compaq recommends that is only necessary to configure the shared storage area. Boot server node 2 with the SmartStart and Support Software CD in the Compaq System Tools Folder. Configuring Server Node 2 1. After the operating system and array controller driver have been fully updated, it is part of the shared drives configured during server node 1 setup. After installing MSCS, install the latest Service Pack. 31. Start the CR3500 Configuration Utility found in the CD-ROM drive...
.... 1-10 Compaq ProLiant CL380 Software User Guide 25. NOTE: Compaq recommends that is only necessary to configure the shared storage area. Boot server node 2 with the SmartStart and Support Software CD in the Compaq System Tools Folder. Configuring Server Node 2 1. After the operating system and array controller driver have been fully updated, it is part of the shared drives configured during server node 1 setup. After installing MSCS, install the latest Service Pack. 31. Start the CR3500 Configuration Utility found in the CD-ROM drive...
Compaq ProLiant CL380 Software User Guide
Page 24
... array controller driver using the CR3500 Configuration Utility, it is current. 26. When configuring server node 2, the utility shows the results of diskettes. After the operating system and array controller driver have not been overwritten by the service pack, rerun the Server Support Software. Restart the system. 28. System Setup and Configuration for Microsoft Windows NT Server 4.0, Enterprise Edition 1-13 Uncheck the detected adapter (Intel 82557 based 10/100 Ethernet PCI Adapter) and install the correct network adapter (Compaq...
... array controller driver using the CR3500 Configuration Utility, it is current. 26. When configuring server node 2, the utility shows the results of diskettes. After the operating system and array controller driver have not been overwritten by the service pack, rerun the Server Support Software. Restart the system. 28. System Setup and Configuration for Microsoft Windows NT Server 4.0, Enterprise Edition 1-13 Uncheck the detected adapter (Intel 82557 based 10/100 Ethernet PCI Adapter) and install the correct network adapter (Compaq...
Compaq ProLiant CL380 Software User Guide
Page 30
... same SCSI ID. Apply power to the shared storage array and boot server node 1 with the SmartStart and Support Software CD in each server node. If you have sufficient software rights to install the operating system and software applications on the Help button. 4. IMPORTANT: This step is done, select Review or Modify Hardware Settings, then press Enter. After you install the software. a. 2-2 Compaq ProLiant CL380 Software User Guide Configuring the System The sections below provide instructions for server...
... same SCSI ID. Apply power to the shared storage array and boot server node 1 with the SmartStart and Support Software CD in each server node. If you have sufficient software rights to install the operating system and software applications on the Help button. 4. IMPORTANT: This step is done, select Review or Modify Hardware Settings, then press Enter. After you install the software. a. 2-2 Compaq ProLiant CL380 Software User Guide Configuring the System The sections below provide instructions for server...
Compaq ProLiant CL380 Software User Guide
Page 33
... support dynamic disks. 6. NOTE: Compaq recommends that you elected to install the latest operating system service pack, run the Compaq Support Paq for Windows 2000 to ensure that is part of Windows 2000 Advanced Server on this utility. NOTE: The Shared Storage CR3500 RAID Controller is only necessary to Windows 2000 Advanced Server. 3. Be sure to store cluster information. Install and configure the Cluster Service component of an array. On server node 1, log on installing and configuring...
... support dynamic disks. 6. NOTE: Compaq recommends that you elected to install the latest operating system service pack, run the Compaq Support Paq for Windows 2000 to ensure that is part of Windows 2000 Advanced Server on this utility. NOTE: The Shared Storage CR3500 RAID Controller is only necessary to Windows 2000 Advanced Server. 3. Be sure to store cluster information. Install and configure the Cluster Service component of an array. On server node 1, log on installing and configuring...
Compaq ProLiant CL380 User Guide
Page 247
... data guarding 1-21 rear panel connectors 1-5 rear view 1-5 reference information 2-8, 3-11 regulatory compliance identification number A-1 notices battery replacement A-7 laser information A-7 laser type A-7 release levers 4-38 Remote Insight Board/PCI 2-9, 3-12 removable media bays 4-57, 5-4 accessing 4-58 removable media devices 4-2 installing 4-56 removable media trays illustrated 4-58 removing 4-58, 4-61, 4-70, 4-72 replacing 4-60 replacing, system board batteries C-1 reset button CR3500 RAID Controller G-4 CR3500 RAID Controller, illustrated G-4 riser board expansion slots locating...
... data guarding 1-21 rear panel connectors 1-5 rear view 1-5 reference information 2-8, 3-11 regulatory compliance identification number A-1 notices battery replacement A-7 laser information A-7 laser type A-7 release levers 4-38 Remote Insight Board/PCI 2-9, 3-12 removable media bays 4-57, 5-4 accessing 4-58 removable media devices 4-2 installing 4-56 removable media trays illustrated 4-58 removing 4-58, 4-61, 4-70, 4-72 replacing 4-60 replacing, system board batteries C-1 reset button CR3500 RAID Controller G-4 CR3500 RAID Controller, illustrated G-4 riser board expansion slots locating...
Compaq ProLiant CL380 User Guide
Page 248
... drive 1-3, 1-9 accessing 4-34 boot drive bay area 1-3, 1-9 cabling 5-18 cache integrated 256-KB 1-10 memory 1-10 caution 4-7 CD-ROM drive 1-3, 1-9 communicating with UPS 4-18 configuring 4-44, 4-47, 4-56, 4-61 disk controllers 1-12 disk drive bay positions 1-14 expansion slot area 1-8 expansion slots 1-5, 1-11 expansion slots, illustrated 1-11 front panel components 1-3 inside view 1-8 internal cable locations 5-3 main features 1-8 power supply 1-5, 1-8 replacing 4-7 powering on 4-17 processor area 1-8 Processor Power Module area 1-8 rear panel connectors 1-5 release levers 4-38 removable...
... drive 1-3, 1-9 accessing 4-34 boot drive bay area 1-3, 1-9 cabling 5-18 cache integrated 256-KB 1-10 memory 1-10 caution 4-7 CD-ROM drive 1-3, 1-9 communicating with UPS 4-18 configuring 4-44, 4-47, 4-56, 4-61 disk controllers 1-12 disk drive bay positions 1-14 expansion slot area 1-8 expansion slots 1-5, 1-11 expansion slots, illustrated 1-11 front panel components 1-3 inside view 1-8 internal cable locations 5-3 main features 1-8 power supply 1-5, 1-8 replacing 4-7 powering on 4-17 processor area 1-8 Processor Power Module area 1-8 rear panel connectors 1-5 release levers 4-38 removable...