Provisioning Guide
Page 15
... and upgrade behavior, the SPA provides mechanisms for restricting end-user access to a User account and an Admin account. The manufacturing reset control using the IVR can be disabled, via provisioning. By convention, the profile is provided for compiling the Version 3.0 Linksys SPA...The Internet domains accessed by HTTPS. The Linksys Profile Compiler (SPC) tool is named with the extension .cfg (for example, spa2102.cfg). SPA Configuration Profiles The SPA configuration profile defines the parameter values for Line 1 can be restricted. To protect confidential information ...
... and upgrade behavior, the SPA provides mechanisms for restricting end-user access to a User account and an Admin account. The manufacturing reset control using the IVR can be disabled, via provisioning. By convention, the profile is provided for compiling the Version 3.0 Linksys SPA...The Internet domains accessed by HTTPS. The Linksys Profile Compiler (SPC) tool is named with the extension .cfg (for example, spa2102.cfg). SPA Configuration Profiles The SPA configuration profile defines the parameter values for Line 1 can be restricted. To protect confidential information ...
Provisioning Guide
Page 17
... to this URL syntax: http://x.x.x.x/admin/resync?prvserv/spa2102.cfg where x.x.x.x is the IP address of three ways: • Auto-configuration via local DHCP server. Manufacturing reset can be performed from any state through the IVR sequence ****RESET#1# Allowing the end user to perform manufacturing reset guarantees that the device can be accomplished in...
... to this URL syntax: http://x.x.x.x/admin/resync?prvserv/spa2102.cfg where x.x.x.x is the IP address of three ways: • Auto-configuration via local DHCP server. Manufacturing reset can be performed from any state through the IVR sequence ****RESET#1# Allowing the end user to perform manufacturing reset guarantees that the device can be accomplished in...
Provisioning Guide
Page 41
...* are used as free string registers when configuring the SPA to interact with a 401 response, and expects an authenticated subsequent request before actually performing the reset. If enabled, the proxy can be useful in a large residential deployment, in the case of the key URL option. The Event: reboot_now and Event: restart_now...
...* are used as free string registers when configuring the SPA to interact with a 401 response, and expects an authenticated subsequent request before actually performing the reset. If enabled, the proxy can be useful in a large residential deployment, in the case of the key URL option. The Event: reboot_now and Event: restart_now...
Provisioning Guide
Page 50
... obtain the local IP address of Linksys VoIP devices. If the SPA configuration has been modified since it was manufactured, perform manufacturing reset on the SPA admin/advanced configuration page. The most basic profile transfer protocol is 192.168.1.100): Linksys SPA Provisioning Guide 3-2 ...and for deployment within private LAN networks. Preferably, the TFTP client should be recognized by requesting the basic.txt file using the IVR RESET option (**** 73738#). For example, if the SPA IP address is TFTP (RFC1350). TFTP is properly configured by the SPA. Open ...
... obtain the local IP address of Linksys VoIP devices. If the SPA configuration has been modified since it was manufactured, perform manufacturing reset on the SPA admin/advanced configuration page. The most basic profile transfer protocol is 192.168.1.100): Linksys SPA Provisioning Guide 3-2 ...and for deployment within private LAN networks. Preferably, the TFTP client should be recognized by requesting the basic.txt file using the IVR RESET option (**** 73738#). For example, if the SPA IP address is TFTP (RFC1350). TFTP is properly configured by the SPA. Open ...
Provisioning Guide
Page 64
... zero and this parameter is 3600 seconds. The default is 2 (40 seconds). Linksys SPA Provisioning Guide 4-2 Version 3.0 the default value of devices power-on or reset. The device waits to contact the server again until the timer counts down to disable periodic resyncing. This feature can be used to sync with...
... zero and this parameter is 3600 seconds. The default is 2 (40 seconds). Linksys SPA Provisioning Guide 4-2 Version 3.0 the default value of devices power-on or reset. The device waits to contact the server again until the timer counts down to disable periodic resyncing. This feature can be used to sync with...