Quick Start Guide
Page 1
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents • Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch • Rackmount Kit • Power Cord • This Quick Start Guide
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents • Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch • Rackmount Kit • Power Cord • This Quick Start Guide
Quick Start Guide
Page 2
Welcome Thank you with attached devices. Auto MDI/MDI-X crossover detection automatically adjusts for choosing the Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch, a Cisco Small Business network communications device. all received packets are given priority over data traffic. Jumbo Frame Support SG...
Welcome Thank you with attached devices. Auto MDI/MDI-X crossover detection automatically adjusts for choosing the Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch, a Cisco Small Business network communications device. all received packets are given priority over data traffic. Jumbo Frame Support SG...
Quick Start Guide
Page 3
... a location where any of the following guidelines: • Make sure that the switch is accessible and that circuit. 1 Installing the Cisco Switch There are three ways to physically install the switch: • Set the switch on a wall. Circuit Overloading-Adding the device to the power outlet must not overload that the cables can be connected...
... a location where any of the following guidelines: • Make sure that the switch is accessible and that circuit. 1 Installing the Cisco Switch There are three ways to physically install the switch: • Set the switch on a wall. Circuit Overloading-Adding the device to the power outlet must not overload that the cables can be connected...
Quick Start Guide
Page 4
... 15 16 17 18 19 20 21 22 23 24 / miniGBIC2 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with a minimum of 4mm width at the head and a shaft diameter of the switch. Cisco is smooth, flat, dry, and sturdy. STEP 3 After ...the brackets are attached to the switch, use suitable screws to securely attach the brackets to any...
... 15 16 17 18 19 20 21 22 23 24 / miniGBIC2 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with a minimum of 4mm width at the head and a shaft diameter of the switch. Cisco is smooth, flat, dry, and sturdy. STEP 3 After ...the brackets are attached to the switch, use suitable screws to securely attach the brackets to any...
Quick Start Guide
Page 5
... / miniGBIC1 Gigabit Link/Act 13 14 15 16 17 18 19 20 21 22 23 24 / miniGBIC2 Gigabit 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 24-P or t 10/ 100/ 1000 Swit ch 193803 Cisco Unmanaged Rackmount Switches 4
... / miniGBIC1 Gigabit Link/Act 13 14 15 16 17 18 19 20 21 22 23 24 / miniGBIC2 Gigabit 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 24-P or t 10/ 100/ 1000 Swit ch 193803 Cisco Unmanaged Rackmount Switches 4
Quick Start Guide
Page 6
... ports. This is active. STEP 3 Repeat Step 1 and Step 2 for full network operation to resume. STEP 4 Connect the power cord to the switch and a power source. 5 Cisco Unmanaged Rackmount Switches STEP 2 Connect the other network device. Otherwise, flow control might not be configurable. On some devices, such as some IP phones and IP...
... ports. This is active. STEP 3 Repeat Step 1 and Step 2 for full network operation to resume. STEP 4 Connect the power cord to the switch and a power source. 5 Cisco Unmanaged Rackmount Switches STEP 2 Connect the other network device. Otherwise, flow control might not be configurable. On some devices, such as some IP phones and IP...
Quick Start Guide
Page 7
... detected. Link/Act LED-(Green) Lights when a link between the corresponding port and another device is powered on. Cisco Unmanaged Rackmount Switches 6 Front Panel Ports The ports and LEDs are located on RJ-45 respond to the miniGBIC interface traffic. Flashes when the port is disabled. • ...The LEDs on the front panel of the switch. 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 LINK GIGABIT ACT RJ-45 Ethernet Ports -Use these ports to connect network devices, such as other brands...
... detected. Link/Act LED-(Green) Lights when a link between the corresponding port and another device is powered on. Cisco Unmanaged Rackmount Switches 6 Front Panel Ports The ports and LEDs are located on RJ-45 respond to the miniGBIC interface traffic. Flashes when the port is disabled. • ...The LEDs on the front panel of the switch. 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 LINK GIGABIT ACT RJ-45 Ethernet Ports -Use these ports to connect network devices, such as other brands...
Quick Start Guide
Page 8
... is connected to the port, is powered on the back panel of the unmanaged rackmount switch. (Only the Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch has a lock.) 276580 276581 7 Cisco Unmanaged Rackmount Switches POWER Side Panel The Kensington lock is located on , and a 1000 Mbps link is... (if present)-(Green) Lights and remains lit when another device is connected to the port, is powered on the side panel of the unmanaged rackmount switch. When the LED is off , the connection speed is under 100 Mbps or nothing is cabled to the port.
... is connected to the port, is powered on the back panel of the unmanaged rackmount switch. (Only the Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch has a lock.) 276580 276581 7 Cisco Unmanaged Rackmount Switches POWER Side Panel The Kensington lock is located on , and a 1000 Mbps link is... (if present)-(Green) Lights and remains lit when another device is connected to the port, is powered on the side panel of the unmanaged rackmount switch. When the LED is off , the connection speed is under 100 Mbps or nothing is cabled to the port.
Quick Start Guide
Page 9
4 Specifications The following tables list the specifications for the unmanaged rackmount switches. Weights and Dimensions Model SF 100-16 16 RJ-45 10/100 ports SF 100-24 24 RJ-45 10/100 ports SF 102-24 24 RJ-45 10/100 ports, 2 shared Gigabit RJ-45/miniGBIC... ports SG 100-16 16 RJ-45 10/100/1000 ports SG 100-24 24 RJ-45 10/100/1000 ports SG 102-24 24 RJ-45 10/100/1000 ports, 2 miniGBIC uplinks Weight 1.251 Kg 2.758 lbs 1.322 Kg 2.915 ... Inch 11x1.75x6.7 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 Cisco Unmanaged Rackmount Switches 8
4 Specifications The following tables list the specifications for the unmanaged rackmount switches. Weights and Dimensions Model SF 100-16 16 RJ-45 10/100 ports SF 100-24 24 RJ-45 10/100 ports SF 102-24 24 RJ-45 10/100 ports, 2 shared Gigabit RJ-45/miniGBIC... ports SG 100-16 16 RJ-45 10/100/1000 ports SG 100-24 24 RJ-45 10/100/1000 ports SG 102-24 24 RJ-45 10/100/1000 ports, 2 miniGBIC uplinks Weight 1.251 Kg 2.758 lbs 1.322 Kg 2.915 ... Inch 11x1.75x6.7 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 Cisco Unmanaged Rackmount Switches 8
Quick Start Guide
Page 10
Features Feature Standards Cabling Type Physical Security Power Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity Description IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, and 802.1p Category 5 or better Kensington security slot on a Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch 100V-240V~ 1A 50-60 Hz FCC Class A, CE 32 to 104ºF (0 to 40ºC) -4 to 158ºF (-20 to 70ºC) 10% to 90% Relative Humidity, noncondensing 10% to 90% Relative Humidity, noncondensing 9 Cisco Unmanaged Rackmount Switches
Features Feature Standards Cabling Type Physical Security Power Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity Description IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, and 802.1p Category 5 or better Kensington security slot on a Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch 100V-240V~ 1A 50-60 Hz FCC Class A, CE 32 to 104ºF (0 to 40ºC) -4 to 158ºF (-20 to 70ºC) 10% to 90% Relative Humidity, noncondensing 10% to 90% Relative Humidity, noncondensing 9 Cisco Unmanaged Rackmount Switches
Quick Start Guide
Page 11
... Business Community www.cisco.com/smb Cisco Small Business Support www.cisco.com/go/smallbizsupport Community Online Technical Support and www.cisco.com/support Documentation (Login Required) Phone Support Contacts www.cisco.com/en/US/support/tsd_cisco_ small_business_support_center_contacts.html Product Documentation Cisco Unmanaged Rackmount Switches Quick Start Guide www.cisco.com/en/US/docs/switches/lan/ csbus/sf10x-xx_sg10x...
... Business Community www.cisco.com/smb Cisco Small Business Support www.cisco.com/go/smallbizsupport Community Online Technical Support and www.cisco.com/support Documentation (Login Required) Phone Support Contacts www.cisco.com/en/US/support/tsd_cisco_ small_business_support_center_contacts.html Product Documentation Cisco Unmanaged Rackmount Switches Quick Start Guide www.cisco.com/en/US/docs/switches/lan/ csbus/sf10x-xx_sg10x...