Campbell Scientific BDR301 Support and Manuals

Get Help and Manuals for this Campbell Scientific item

View All Support Options Below
Free Campbell Scientific BDR301 manuals!
Problems with Campbell Scientific BDR301?

Ask a Question

Popular Campbell Scientific BDR301 Manual Pages

Operation Manual - Page 5

...LU 5-13 l1 Capability L.2 Programming 1-3 J_-5 1 ? Mamnrrz 1,.4 Computer Operations 1.5 Specif icati-ons L-4 1-5 L-6 2. C Command 4-3 4-3 4.5 Data Retrieval 4.6 Error Logr 4-4 4-5 4.7 '1'l-me sec Locr 4.8 Data Note St.orage and Retrieval 4.9...Status 4. COMPUTER COMMAI{DS 3-1 3-2 3-3 4.L Command Basics 4-L 4.2 Help Command 4-2 4.3 Status 4.4 Setting and Displaying the Clock -
Operation Manual - Page 6

... Supplies 6.2 Protection from the Environment 6.3 Grounding 6.4 Use of Flags: Program Control 7 .10 END, fnsLruction 95 7 .L1 Error Codes 7 .r2 Program Syntax and Download Rules 8. DTRECT PROGRAMMING '7 1 *1, *A, and *C ModeS t -z Program Instruction Tlpes 7.3 Parameter Data Types 7.4 Repetitions 7.5 Entering Negative Numbers 7.6 Indexing Input Locations 7.7 Input Range and Overrange Detection...
Operation Manual - Page 9

...applied for sustained period. A supply voltage in data interpretation, retrieve the Error Log and Time Set Log when retrieving data. External power must be supplied when SDI-I-2 sensors ... wil1 cause errors and possible overranging on than 5.5 the pulse volts for installing found in Section 5.1.1. the internal supply are used. SELECTED OPERATING DETAILS 1 Instructions for signal ...
Operation Manual - Page 25

...responses to Code for all ASCII commands. 5. set its RS232 port connected to the dataloggerrs RS232 connect.or is used to receive a command. retrieve and review Data Tabl-es - error loq was...".umber parameters, and terminated with its baud raLe to that it to al-low it is set, the datalogger will send back the prompt H * = Help, errorg:nnnn signaling that of...
Operation Manual - Page 26

... l-ast; 1R=a11 notes c Display/Set date, time nI Display/Set input location n n,mI Measure/Display ...{D H HeIp menu. The datalogger sends ASCII data with code n 1,2X Transparent to zero the command buffer. no ... in its measurement and processing tasks whil-e servicing the commands. SECTTON 4. Aconmim1a1nedgba1ufcfehra,rarcetLeurrninicnrgemae*n.ts a counter and zeros t....
Operation Manual - Page 30

... cal-culated signature is stored. 7 Error B is cal-cul-ated and compared with the set in Instruct.ion 84, and C command. Program table overrun -LZ I5 - Resetting the datalogger clock does not cause error 12. An exanrpJ.e error 1og is if t.he flagged when the watchdog performs this reset. system updates, Error code 08 ot is shown below...
Operation Manual - Page 32

... BDR calculates the necessary offset. For example, to the command state. and current reading will show an error 7 at midnight the night aft,er an offset was changed . Command needs to be displayed. Key... when an offset is changed in the program. If the actualvalue of the offset is used to set the offset applied to match the staff gauge. I ' DATA ARE DELETED BY ISSUING THIS COMMATTD ...
Operation Manual - Page 33

...program. COMPUTER COMMAIIDS The 7W command prompt programming method is commonly done with code number n Three l-evels of security using the prompt programming Mode. not ...be edited, or programming pmreotghiroadmssmdaeyvbeelopreevdieinweedit.heTrheth*e1 prompt or direct Mode is are set possible, in Campbell's PC208 software package. Sending nL unl-ocks that level...
Operation Manual - Page 34

.... Exit telecommunications . xxx Input Locs:xxxx Prgm Bytes:xxxx Storage : +xxxxx. SECTTON 4. Errors= xxxx PROM ID:+xxxxx SN: +xxxx. Reaf time Time of run time errors since erasi-ng error 1og PROM identification number datalogger serial number Checksum Display/set time. Display Inputs/Enter Values Display val-ue in progiram EPEroPgRrOaMm(sciaglnibartuarteion) signature Calibration...
Operation Manual - Page 35

...spr-12 L2X Communicate with oldest. Error and Time Set, Loqs 1U 1111U 2U 2222U Send error log Erase error 1og Send time set log Erase time set loq 4-LL SECTION 4. s Time ... AI{D AI.,I {DS Data Retrieval fl,b, t, sD Send Data; Securitw nI-., Unlock Security (*C lutode) with code word n. COMPUTER COMMA.I , DATA ARE DEIJETED BY ISSUING THIS COMI{AND Data Notes R l-R 432LS Get Data ...
Operation Manual - Page 37

... are stored, i.e., the time period over which processed data are stored. Output programming is applied. the interval at which def i-ne: - subroutines, conditj-onal output, set to the measurement results. - The datalogger prompts for simple programs that measure, process, and store data. which define: - I - The reverse is also true. 5.1 PROMPT PROGRJA...
Operation Manual - Page 38

z NOTE 7W COMMAIiID ENIRY Trrhceursseoqruuepntcreoonfthcehacroamctpeurstertois ennoatblset.a"cnIdeaardr screen'r in the designated LOCation. Set the control or minutes prior port to be measured at a different intervals. If all - and computers. rrlwrr lists the program generated in Table 2. 5.2.L TABI,E NT'...
Operation Manual - Page 39

... int.erval is identical to Tab1e L if to zero and the values for relay driver information. 5-3 Input Tabl-e Number 02 Measurement Interval mins 0005 Ctrl Port prior turn .... The interval must be less than t.he computer 5 space bar to set Table 2 is strike t.he control onrrwill unit.s. Tinchthe,aecnrvogaenltt.roolNrepomoteratitnhisathteauusntaoimtmseaaftosicrathtlhleyes"Me"Cet...
Operation Manual - Page 54

... passes through 93. A digital output port is set low or high (0V low, 5V high) ...offers the A2I-REL-12 Four Channel Relay Driver for the differential measurement to some device. ...FOR SWITCHING REI'AYS The digital control port can be a problem when the BDR is referenced to a device without . ...order for use with Program Cont,rol Instructions 83 through the relay coiI, closing the...
Operation Manual - Page 64

FIag 9 is specific to a cumulative total residing in the instruction is true. Table 7.9-2 lists these codes. FIag Description Flag 1to 8 - I ) . Flag 1-9 high Set Flag 1-9 1ow Then Do Exit loop if true Exit loop if fal-se Set Port high Set Port l-ow Toggle Port Pulse Port 7-8 SECTION 7. Intermediate Processing can be used in datalogger programs (Table 7.9-I ,OGICAI...

Campbell Scientific BDR301 Reviews

Do you have an experience with the Campbell Scientific BDR301 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Ask a New Question
Use the box below to post a new question about Campbell Scientific BDR301.
Manuals / Documents
Download any of our Campbell Scientific BDR301 manuals for free!

We have the following 1 documents available for the Campbell Scientific BDR301:
  • Operation Manual
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific BDR301 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific BDR301 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.