User Manual and Install Guide
Page 57
... following table. Caution: During initialization, all data is complete. 12 Press Esc until the build process is deleted from the disk. Read Caching Press Enter to use the default granularity of GB. Create RAID via Press Enter to use the default (256 KB). However, performance is...press Enter. Array Size Press Enter, then press Enter again to keep. 6 Press Y, then press Enter. Write Caching Press Enter to use the default (Enable Read) [Done] Press Enter. 10 When a cache warning message displays, type Y. 11 Once the array is created, a message displays telling you want to use...
... following table. Caution: During initialization, all data is complete. 12 Press Esc until the build process is deleted from the disk. Read Caching Press Enter to use the default granularity of GB. Create RAID via Press Enter to use the default (256 KB). However, performance is...press Enter. Array Size Press Enter, then press Enter again to keep. 6 Press Y, then press Enter. Write Caching Press Enter to use the default (Enable Read) [Done] Press Enter. 10 When a cache warning message displays, type Y. 11 Once the array is created, a message displays telling you want to use...
User Manual and Install Guide
Page 108
...interval at which it is supported on page 109. You can modify the read and write cache settings for an array. Note: maxCache Read Caching is powered off. The Modify Cache Settings window opens. 3 Enable or disable read -intensive applications. Note: Power Off ... press Ctrl+C. Modifying Cache Settings You can also modify the maxCache settings. To modify the cache settings for "write-through" caching 6 Press Tab. 7 Select the maxCache Read Cache setting (Enable/Disable). 8 Press Tab. 9 Press Enter to accept the values. Appendix C: Using the Adaptec RAID Configuration Utility ●...
...interval at which it is supported on page 109. You can modify the read and write cache settings for an array. Note: maxCache Read Caching is powered off. The Modify Cache Settings window opens. 3 Enable or disable read -intensive applications. Note: Power Off ... press Ctrl+C. Modifying Cache Settings You can also modify the maxCache settings. To modify the cache settings for "write-through" caching 6 Press Tab. 7 Select the maxCache Read Cache setting (Enable/Disable). 8 Press Tab. 9 Press Enter to accept the values. Appendix C: Using the Adaptec RAID Configuration Utility ●...
User Manual and Install Guide
Page 112
... running tasks. For Series 2 and Series 5 controllers, default is enabled. When set to Drive Specific, write cache is enabled/disabled on a per-drive basis in Adaptec Storage Manager.) When set to the BIOS for logical arrays. Note that support BBS, the controller presents attached... bootable devices up to Enable All, write cache is enabled on all disk drives on the controller. (Enabling the write cache overrides any individual drive settings in Adaptec Storage Manager. This is relevant for boot device selection. Default is Activity ...
... running tasks. For Series 2 and Series 5 controllers, default is enabled. When set to Drive Specific, write cache is enabled/disabled on a per-drive basis in Adaptec Storage Manager.) When set to the BIOS for logical arrays. Note that support BBS, the controller presents attached... bootable devices up to Enable All, write cache is enabled on all disk drives on the controller. (Enabling the write cache overrides any individual drive settings in Adaptec Storage Manager. This is relevant for boot device selection. Default is Activity ...
User Manual and Install Guide
Page 113
...which the system is set to Dynamic, performance criteria adjusts automatically based on controller usage, RAID level, and disk drive type. Appendix C: Using the Adaptec RAID Configuration Utility ● 112 Option Description Backplane Mode ● Series 2, Series 5, Series 6 Controllers: When set the backplane mode explicitly, select... time from which the system should operate in bold type. Default is -12:00 to 0. When set to Big Block Bypass, DRAM write cache is set to +12:00. By default, it is located. The valid range is Dynamic. Default is 00:00 to 00:00....
...which the system is set to Dynamic, performance criteria adjusts automatically based on controller usage, RAID level, and disk drive type. Appendix C: Using the Adaptec RAID Configuration Utility ● 112 Option Description Backplane Mode ● Series 2, Series 5, Series 6 Controllers: When set the backplane mode explicitly, select... time from which the system should operate in bold type. Default is -12:00 to 0. When set to Big Block Bypass, DRAM write cache is set to +12:00. By default, it is located. The valid range is Dynamic. Default is 00:00 to 00:00....
User Manual and Install Guide
Page 152
... disk drives 50 connecting external devices 53 CRC Checking setting 113 data protection 19 descriptions 17 to 32 disk drives 42 Drive's Write Cache setting 111 event log 114 figures 17 to 32 firmware 116 flashing 86 I2C connector specifications 122 installation options 45 installing 47 modifying... erasing 108 stopping a secure erase 108 solid state 18, 42, 50 types of connections 114 verifying 113 drive requirements 42 Drive's Write Cache setting 111 driver and operating system installation 59 driver disk 60 driver installation 72 to 78 drivers installing on FreeBSD 78 installing on Solaris...
... disk drives 50 connecting external devices 53 CRC Checking setting 113 data protection 19 descriptions 17 to 32 disk drives 42 Drive's Write Cache setting 111 event log 114 figures 17 to 32 firmware 116 flashing 86 I2C connector specifications 122 installation options 45 installing 47 modifying... erasing 108 stopping a secure erase 108 solid state 18, 42, 50 types of connections 114 verifying 113 drive requirements 42 Drive's Write Cache setting 111 driver and operating system installation 59 driver disk 60 driver installation 72 to 78 drivers installing on FreeBSD 78 installing on Solaris...