Aspire M1100/3100/5100 Power M3100 Service Guide
Page 8
... Time 28 SATA Devices 28 Drive A 28 Halt On 28 Base Memory, Extended Memory, and Total Memory 28 Advanced BIOS Features 29 Virus Warning 29 CPU Internal Cache/External Cache 29 Quick Power On Self Test 30 First / Second / Third Boot Device 30 Boot Other Device 30 Boot Up Floppy Seek...
... Time 28 SATA Devices 28 Drive A 28 Halt On 28 Base Memory, Extended Memory, and Total Memory 28 Advanced BIOS Features 29 Virus Warning 29 CPU Internal Cache/External Cache 29 Quick Power On Self Test 30 First / Second / Third Boot Device 30 Boot Other Device 30 Boot Up Floppy Seek...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 9
... Snoop 43 Assign IRQ For VGA 43 Assign IRQ for USB 44 PCI Latency Timer (CLK 44 Maximum Payload Size 44 PC Health Status 45 CPU Shut Down Temperature 45 Frequency & Voltage Control 47 Spread Spectrum 47 SB600 Spread Spectrum 47 Load Optimized Defaults 48 Set Supervisor Password 49 iii
... Snoop 43 Assign IRQ For VGA 43 Assign IRQ for USB 44 PCI Latency Timer (CLK 44 Maximum Payload Size 44 PC Health Status 45 CPU Shut Down Temperature 45 Frequency & Voltage Control 47 Spread Spectrum 47 SB600 Spread Spectrum 47 Load Optimized Defaults 48 Set Supervisor Password 49 iii
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 13
... Audio connector with 6 JACKS • DVI-I port • HDMI port • PS2 port • Print port • Onboard connectors: • One CPU socket • Four DDR2 memory sockets • One PCI Express x16 slot • One PCI Express x1 slot • Two PCI slots • One ... audio header, compliant to Intel FPIO standard specification • One 2*5 pin serial port connector • One 1*4 pin AUX-In connector • One 4-pin CPU fan connector • One 3-pin system fan connector with linear circuit • One 24-pin + 4-pin ATX interface PS3/PS2 SPS connector • One...
... Audio connector with 6 JACKS • DVI-I port • HDMI port • PS2 port • Print port • Onboard connectors: • One CPU socket • Four DDR2 memory sockets • One PCI Express x16 slot • One PCI Express x1 slot • Two PCI slots • One ... audio header, compliant to Intel FPIO standard specification • One 2*5 pin serial port connector • One 1*4 pin AUX-In connector • One 4-pin CPU fan connector • One 3-pin system fan connector with linear circuit • One 24-pin + 4-pin ATX interface PS3/PS2 SPS connector • One...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 28
...8226; Integrated a DirectX 9.0 compliant 2D/3D graphics core • Integrated an ATI Radeon X700-based graphics engine • Supports LDTSTP interface, CPU throttling, and stutter mode • The RS690 incorporates ATI's innovative Avivo™ display architecture • A new TV encoder, based on design ...to three independent monitors • Integrated 400 MHz DAC for external desktop displays • Primary HyperTransport link up to 1.0 GHz to the CPU • One x4 A-link Express II interface (PCI Express 1.1 compliant) • PCI Express 16 lane link interface for external graphics...
...8226; Integrated a DirectX 9.0 compliant 2D/3D graphics core • Integrated an ATI Radeon X700-based graphics engine • Supports LDTSTP interface, CPU throttling, and stutter mode • The RS690 incorporates ATI's innovative Avivo™ display architecture • A new TV encoder, based on design ...to three independent monitors • Integrated 400 MHz DAC for external desktop displays • Primary HyperTransport link up to 1.0 GHz to the CPU • One x4 A-link Express II interface (PCI Express 1.1 compliant) • PCI Express 16 lane link interface for external graphics...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 31
... 8-bit Analog to Digital Converter • 3 thermal inputs from remote thermal resistor or thermal diode or diode- connected transistor • Provides VID0-VID7 support for CPU Vcore identification • 8 voltage monitor inputs (VBAT is measured internally) • Watch dog comparison of independent stereo sound output through the front panel output. •...
... 8-bit Analog to Digital Converter • 3 thermal inputs from remote thermal resistor or thermal diode or diode- connected transistor • Provides VID0-VID7 support for CPU Vcore identification • 8 voltage monitor inputs (VBAT is measured internally) • Watch dog comparison of independent stereo sound output through the front panel output. •...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 33
... ACPI mode. Suspend Mode • Independent power management timer (two to 120 minutes, time step = 10 minutes) or pushing external switch button. • CPU goes into SMM. • CPU asserts STPCLK# and goes into the Stop Grant state. • LED on the panel turns amber color. • Hard disk drive goes into...
... ACPI mode. Suspend Mode • Independent power management timer (two to 120 minutes, time step = 10 minutes) or pushing external switch button. • CPU goes into SMM. • CPU asserts STPCLK# and goes into the Stop Grant state. • LED on the panel turns amber color. • Hard disk drive goes into...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 39
...For OS [1.4] OS Select For DRAM > 64MB [Non-OS2] HDD S.M.A.R.T. CPUs from the main DRAM into cache Chapter 2 29 When the CPU requests data, the system transfers the requested data from 486-type on up contain internal cache memory, and most, but not all, modern ...) cache memory. You can press ESC to return to the main menu setting page. Advanced BIOS Features This page displays advanced BIOS features. CPU Internal Cache/External Cache Cache memory is additional memory that is much faster than conventional DRAM (system memory). Phoenix - Capability [Disabled] Silent Boot...
...For OS [1.4] OS Select For DRAM > 64MB [Non-OS2] HDD S.M.A.R.T. CPUs from the main DRAM into cache Chapter 2 29 When the CPU requests data, the system transfers the requested data from 486-type on up contain internal cache memory, and most, but not all, modern ...) cache memory. You can press ESC to return to the main menu setting page. Advanced BIOS Features This page displays advanced BIOS features. CPU Internal Cache/External Cache Cache memory is additional memory that is much faster than conventional DRAM (system memory). Phoenix - Capability [Disabled] Silent Boot...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 40
... default setting is booted. Security Option If you are confident that was written for an earlier generation of memory and you are generated by the CPU. You might like to enable this item to enter the Setup Utility. Gate A20 Option This item defines how the system handles legacy software that...
... default setting is booted. Security Option If you are confident that was written for an earlier generation of memory and you are generated by the CPU. You might like to enable this item to enter the Setup Utility. Gate A20 Option This item defines how the system handles legacy software that...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 55
... (°C) [ 2] PWM Start SYS Temp. (°C) [ 45] Slope PWM Value 2 [ 2] Delta Temp. (°C) 2 [ 2] System Smart FAN Control [Enabled] PWM Start CPU Temp (°C) [ 45] Start PWM Value (0~127) [ 48] Slope PWM Value [ 2] Delta Temp. (°C) [ 2] PWM Start SYS Temp. (°C) [ 42] Slope ...Move Enter: Select +/-/PU/PD :Value F10: Save and Exit ESC:Exit F1: General Help F5: Previous Values F7: Optimized Defaults CPU Shut Down Temperature Enables you to set the maximum temperature that supports hardware monitoring, you can reach before powering down. Phoenix - Award ...
... (°C) [ 2] PWM Start SYS Temp. (°C) [ 45] Slope PWM Value 2 [ 2] Delta Temp. (°C) 2 [ 2] System Smart FAN Control [Enabled] PWM Start CPU Temp (°C) [ 45] Start PWM Value (0~127) [ 48] Slope PWM Value [ 2] Delta Temp. (°C) [ 2] PWM Start SYS Temp. (°C) [ 42] Slope ...Move Enter: Select +/-/PU/PD :Value F10: Save and Exit ESC:Exit F1: General Help F5: Previous Values F7: Optimized Defaults CPU Shut Down Temperature Enables you to set the maximum temperature that supports hardware monitoring, you can reach before powering down. Phoenix - Award ...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 56
... System FAN speed Scroll to these items and enter values as required to customize the Thermal Profile: • CPU Temp. Offset • CPU Warning Temperature • CPU Smart FAN Control • PWM Start CPU Temp • Start PWM Value • Slope PWM Value • Delta Temp. • PWM Start ...SYS Temp. • Slope PWM Value 2 • Delta Temp. (°C) 2 • System Smart FAN Control • PWM Start CPU Temp (°C) • Start PWM Value (0~127) • Slope PWM Value • Delta Temp. (°C) • PWM Start SYS Temp. (°C) •...
... System FAN speed Scroll to these items and enter values as required to customize the Thermal Profile: • CPU Temp. Offset • CPU Warning Temperature • CPU Smart FAN Control • PWM Start CPU Temp • Start PWM Value • Slope PWM Value • Delta Temp. • PWM Start ...SYS Temp. • Slope PWM Value 2 • Delta Temp. (°C) 2 • System Smart FAN Control • PWM Start CPU Temp (°C) • Start PWM Value (0~127) • Slope PWM Value • Delta Temp. (°C) • PWM Start SYS Temp. (°C) •...
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 67
11. Disconnect the HDD power and data cables. 12. Slide the HDD holder as shown and remove the HDD from their MB connectors. CPU Cooler System Fan 13. Chapter 3 57 Disconnect the System Fan and CPU Cooler power cable from the chassis.
11. Disconnect the HDD power and data cables. 12. Slide the HDD holder as shown and remove the HDD from their MB connectors. CPU Cooler System Fan 13. Chapter 3 57 Disconnect the System Fan and CPU Cooler power cable from the chassis.
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 68
Note: For the AM10, take care not to damage the USB ports on the bottom right-hand side of the bezel. 14. Release the four screws as shown and remove the HDD from the chassis. 58 Chapter 3 Release the three securing latches and remove the front bezel. AM50 AM30 AM10 15. Slide the ODD holder as shown and remove the CPU Cooler from the chassis. 16. Note: For the AM50 and AM30, take care not to damage the USB ports at the top of the bezel.
Note: For the AM10, take care not to damage the USB ports on the bottom right-hand side of the bezel. 14. Release the four screws as shown and remove the HDD from the chassis. 58 Chapter 3 Release the three securing latches and remove the front bezel. AM50 AM30 AM10 15. Slide the ODD holder as shown and remove the CPU Cooler from the chassis. 16. Note: For the AM50 and AM30, take care not to damage the USB ports at the top of the bezel.
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 69
Repeat as shown and lift the fan clear of the chassis. 19. Chapter 3 59 Push the two locking latches away from the motherboard. Remove the four System Fan screws as necessary to release the memory. Push and release the CPU latch and remove the CPU from the memory unit at the same time to remove all memory. 18. 17.
Repeat as shown and lift the fan clear of the chassis. 19. Chapter 3 59 Push the two locking latches away from the motherboard. Remove the four System Fan screws as necessary to release the memory. Push and release the CPU latch and remove the CPU from the memory unit at the same time to remove all memory. 18. 17.
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 72
Repeat for all memory modules. 62 Chapter 3 Insert the CPU in to the motherboard. Close the CPU latch. 4. Insert the System Fan in to the chassis as secure the 4 screws as shown until the securing latches click into the slot, taking care to align the locating lug. Insert the memory into place. Push down as shown. 5. 3.
Repeat for all memory modules. 62 Chapter 3 Insert the CPU in to the motherboard. Close the CPU latch. 4. Insert the System Fan in to the chassis as secure the 4 screws as shown until the securing latches click into the slot, taking care to align the locating lug. Insert the memory into place. Push down as shown. 5. 3.
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 73
Fit the CPU cooler to lock it in place. CPU Cooler System Fan 8. 6. Insert the ODD in to the chassis and slide the ODD holder as shown to the MB and fasten the four screws shown bellow. 7. Chapter 3 63 Connect the System Fan & CPU Cooler power-cables to the MB connectors.
Fit the CPU cooler to lock it in place. CPU Cooler System Fan 8. 6. Insert the ODD in to the chassis and slide the ODD holder as shown to the MB and fasten the four screws shown bellow. 7. Chapter 3 63 Connect the System Fan & CPU Cooler power-cables to the MB connectors.
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 81
Chapter 5 Jumper and Connector Information Introduction to Connectors Main Board Placement 1 2 3 4 5 6 7 8 9 10 11 21 12 13 14 15 22 16 17 18 23 19 20 24 26 25 27 28 30 29 31 32 33 34 35 37 36 38 39 40 41 # Component 1 PS/2 CONN 3 LPT CONN 5 1394 CONN 7 LAN CONN 9 LAN CHIP 11 4 PIN POWER 13 CPU FAN 15 CLK GEN # Component 2 HDMI CONN 4 VGA CONN 6 USB CONNS 8 AUDIO CONNS 10 AUDIO CHIP 12 SYSTEM FAN 14 COM PORT 16 PCIE 1X SLOT Chapter 5 71
Chapter 5 Jumper and Connector Information Introduction to Connectors Main Board Placement 1 2 3 4 5 6 7 8 9 10 11 21 12 13 14 15 22 16 17 18 23 19 20 24 26 25 27 28 30 29 31 32 33 34 35 37 36 38 39 40 41 # Component 1 PS/2 CONN 3 LPT CONN 5 1394 CONN 7 LAN CONN 9 LAN CHIP 11 4 PIN POWER 13 CPU FAN 15 CLK GEN # Component 2 HDMI CONN 4 VGA CONN 6 USB CONNS 8 AUDIO CONNS 10 AUDIO CHIP 12 SYSTEM FAN 14 COM PORT 16 PCIE 1X SLOT Chapter 5 71
Aspire M1100/3100/5100 Power M3100 Service Guide
Page 87
Jumpers Jumper/Header Name CPUFAN (3 PIN) Function CPU FAN HEADER Definition 1: GND 2: POWER 3: SENSE SYSFAN (3 PIN) Yellow is symbol, Red is Pin1 of symbol SYSTEM FAN HEADER 1: GND 2: POWER 3: SENSE CLR_CMOS (3 PIN) OBR Yellow is symbol, Red is Pin1 of symbol CLEAR CMOS HEADER 1,2: CLEAR CMOS (1: Ground, 2: RTC_RSTJ) 2,3: NORMAL (3: VCC_RTC) Yellow is symbol, Red is Pin1 of symbol System Recover HEADER 1: SYS_RECOVER 2: GND Yellow is symbol, Red is Pin1 of symbol Chapter 5 77
Jumpers Jumper/Header Name CPUFAN (3 PIN) Function CPU FAN HEADER Definition 1: GND 2: POWER 3: SENSE SYSFAN (3 PIN) Yellow is symbol, Red is Pin1 of symbol SYSTEM FAN HEADER 1: GND 2: POWER 3: SENSE CLR_CMOS (3 PIN) OBR Yellow is symbol, Red is Pin1 of symbol CLEAR CMOS HEADER 1,2: CLEAR CMOS (1: Ground, 2: RTC_RSTJ) 2,3: NORMAL (3: VCC_RTC) Yellow is symbol, Red is Pin1 of symbol System Recover HEADER 1: SYS_RECOVER 2: GND Yellow is symbol, Red is Pin1 of symbol Chapter 5 77