Question posted by sillisue1999 on July 21st, 2011

Doesn't Stay On

I have a Sharp CV-P10RC portable room air conditioner. It stopped running and now shows flashing lights in the following sequence:TimerTimer + OperationTimerTimer + OperationTimer + OperationThen a pause and the sequence of lights repeats.Please let me know what this light sequence means. Also, I did clean out the air filters, I turned off the unit for 30 minutes (unplugged), and I also TRIED to drain the water out of the unit. I have never been successful at draining the unit: the instructions in the manual do not result in any water coming out of either of the drain plugs. I would like to know how to do this as well.

Current Answers

Answer #1: Posted by jersandex on May 31st, 2012 9:28 PM
jersandex

Member since:
May 31st, 2012

Points: 80
180
points
Yes, the exhaust blower was jammed for some reason. No need to take off the back of the unit. With unit off, remove exhaust hose, push on the blower with a pole/stick. If you cannot release it with the unit off, try it with the unit on. Which is what I had to do. As soon as the blower comes alive, remove poking device immediately! Being as it is close to Memorial Day, I happened to have an American Flag very close by! USA,USA,USA! Keep at it, it should work. Took me a couple tries, but in the end it works great now. Honestly, the fix took less than a minute.

Answer #2: Posted by clvandyke on July 24th, 2011 1:24 PM
clvandyke

Member since:
July 24th, 2011

Points: 160
160
points
I have the same model with the same problem. I found tha that the exhaust squirel fan is jamed and doesn't rotate. I don't know how to open the case for further troubleshooting. Hope this helps.

 

Clarence

Answer #3: Posted by cpimentel777 on May 17th, 2014 8:18 PM
cpimentel777

Member since:
February 23rd, 2013

Points: 10
100
points
I just drain the water tray, it was full.....now it is working like a champ....

Related Sharp CV-P10RC Manual Pages

CV-P10RC Operation Manual - Page 3

...8226; MEGA COOL OPERATION E-23 • ONE-HOUR OFF TIMER E-23 • TIMER OPERATION E-24 • MAIN UNIT OPERATION E-26 • DRAINAGE E-27 • MAINTENANCE E-28 • BEFORE CALLING FOR SERVICE E-29 Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P10RC This device complies with Part 18 of your new air conditioner. Responsible Party: SHARP ELECTRONICS CORPORATION. This...
CV-P10RC Operation Manual - Page 4

... CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS THE INTERNET: www.sharpusa.com Please provide the following information when you call : model number, serial number, date of purchase, your complete mailing...
CV-P10RC Operation Manual - Page 5

...this Sharp brand ...CV-P10RC Portable Air Conditioner. Appearance items of incidental or consequential damages, so the above limitation may not apply to the first consumer purchaser that it . USERS SHARP ELECTRONICS CORPORATION warrants to you need service for this information available when you . In order to enforce the rights under this limited warranty, the purchaser should follow...
CV-P10RC Operation Manual - Page 6

... Radio or TV Interference If this manual. • Do not modify any part of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into an appropriate wall socket. Only use in conjunction with any abnormality with a new...
CV-P10RC Operation Manual - Page 7

...plug can cause electrical shock or equipment damage. • Drainage should be reduced or stop completely. In the event of an electrical short circuit, grounding reduces the risk of...electrical box USAGE CAUTIONS • Ventilate the room periodically during dehumidification mode. The drained water may be performed whenever moving the air conditioner. (See Page 27) If any maintenance ...
CV-P10RC Operation Manual - Page 8

... any lights or appliances that keeps the compressor turned off the air conditioner when no one is set close to shut off any openings into the room. • When cooling operation is full, the unit stops operating and TIMER, OPERATION and MEGA COOL lamps will enter the room from outside the room via the exhaust hose while in safety device may run...
CV-P10RC Operation Manual - Page 9

...reach of a properly rated grounded socket. • Never place any obstacles around the air inlet or outlet of space from the wall for direct installation.) E-7 Use caution when... WINDOW PANEL INSTALLATION 1. Screwdriver(medium size Phillips) 2. Knife or scissors 4. ENGLISH LOCATION • The air conditioner should only be rolled on smooth, flat least 12" (30cm) of the unit. •...
CV-P10RC Operation Manual - Page 10

... 4 4 PLASMACLUSTER Lamp 5 (blue) 6 5 Remote control signal receiver window 7 6 POWER Button 8 9 7 OPERATION Lamp (red) 0 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y u y Drainage nozzle and stopcock u Power supply cord hooks...
CV-P10RC Operation Manual - Page 11

ENGLISH REMOTE CONTROL 1 2 3 4 5 6 7 8 9 0 q w e r t 1 Transmitter 2 Display 3 POWER Button 4 LIGHTS Button 5 TEMPERATURE Button 6 PLASMACLUSTER Button 7 1 hr OFF Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL Button REMOTE CONTROL DISPLAY y MODE SYMBOLS : COOL : DEHUMIDIFICATION y : FAN : VENTILATION u ...
CV-P10RC Operation Manual - Page 16

...unit. Surface of window exhaust adapter marked "TOP" should be as short as possible for operational efficiency; however, it must be installed or removed in accordance with container(minimum...DEHUMIDIFICATION with the usage mode. Insert the two projections on the window frame side when it stops. three times) until it is installed in a double-hung sash window. Surface of window ...
CV-P10RC Operation Manual - Page 18

PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. Disconnect the power plug and call for use . •...batteries from the remote control. You will not be performed. The circuit breaker is activated, power is supplied, and the air conditioner is functioning correctly. 4 Press the RESET button until you will hear a CLICK if the circuit breaker is now ready...
CV-P10RC Operation Manual - Page 19

...it to the unit when not in the same room may interfere with transmission of the signal. • The unit may adversely affect its operation. To prevent the remote control from the unit,... Make sure nothing, such as curtains, blocks the signal receiver window. • The remote control operates up slightly and pull it . If necessary, close the curtains to 23 feet (7 meters) away. evisions,...
CV-P10RC Operation Manual - Page 20

...HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn the drainage nozzle to the CLOSE position, ... the desired fan speed. E-18 COOL DEHUM FAN VENT 2 Press the POWER button to start operation. 2 • The red OPERATION lamp on the unit will light. 3 3 Press the TEMPERATURE button to set the desired temperature. • The temperature can ...
CV-P10RC Operation Manual - Page 21

... discharged from the drainage nozzle. • When the stopcock is preset to slightly drop the room temperature, but dehumidification performance will become full, the unit will stop operating and the TIMER, OPERATION and MEGA COOL lamps will rise. Operate dehumidification with a minimum capacity of the water is not desirable, install the exhaust...
CV-P10RC Operation Manual - Page 22

... VENT mode. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. Install the exhaust hose (See Page 14), turn off . QUIET LOW HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will light. • The temperature cannot be set the desired...
CV-P10RC Operation Manual - Page 23

...21 Horizontal louvers LEFT / RIGHT AIR FLOW DIRECTION Hold the vertical louver as shown in the COOL mode with the fan speed set automatically when operated the next time. CATION mode for... The horizontal louvers will stop moving. • The adjusted position will be memorized and the same position will be changed. ENGLISH TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION 1 Press ...
CV-P10RC Operation Manual - Page 24

...set during operation. • The remote control will display " ". • The blue PLASMACLUSTER lamp on the air conditioner. • To turn off the PLASMACLUSTER Lamp, press the LIGHTS button. • PLASMACLUSTER operation cannot be...into the room. NOTES: • Use of positive and negative ions are released into the air. 1 Press the PLASMACLUSTER button during VENTILATION mode....
CV-P10RC Operation Manual - Page 25

... unit will stop operating after the unit has run for 30 minutes in MEGA COOL mode. • The extra high fan speed may automatically slow down to operate the unit for another hour before the ONE-HOUR OFF TIMER is activated, press the 1hr OFF TIMER button again during operation. ENGLISH MEGA COOL OPERATION In this operation, the air conditioner fan...
CV-P10RC Operation Manual - Page 30

... operate the unit without the filter. Periodically remove the window exhaust adapter from the wall socket before reinstalling them . Doing so may be reduced or stop ...Operate the unit in serious damage to the unit. To avoid damaging the unit, do not use harsh chemicals or abrasive cleaners on any maintenance. Insect guard net MAINTENANCE AFTER AIR CONDITIONER...
CV-P10RC Operation Manual - Page 31

... the power plug. (See page16) AIR CONDITIONER DOES NOT COOL PROPERLY • Is it set , the TIMER setting will be cancelled and will blow out if the cooling coil is full. It must not be malfunctioning, check the following points before calling for about 5 minutes. • Are the OPERATION, TIMER and MEGA COOL lamps blinking? Change...

Similar Questions

Sharp Cv-p10pc Portable Room Ac Fuse Plug Issue
My Sharp Cv-p10pc Portable Room Ac Fuse Plug Wont Reset Itself. Can I Replace It?
(Posted by shirlaylee 8 years ago)
Sharp Cv-p10rc Compressor Goes Offline
I've had my Sharp CV-P10RC since 2012 and it's work well until this weekend. The compressor goes off...
(Posted by pschmidt700 8 years ago)
Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV-P10RC manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.