Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by dfenwasazi on August 25th, 2013

How Do I Remove The Case On A Sharp Cv-10nh Portable Room Air Conditioner

The person who posted this question about this Sharp product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...PRECAUTIONS E-4 • LOCATION E-7 • INCLUDED E-7 • PART NAMES E-8 • INSTALL WINDOW PANEL E-10 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-14 • PRE-OPERATION CHECKS E-16 • COOL MODE E-18 • DEHUMIDIFICATION ...manual explains the proper use of your new air conditioner. This manual should be kept in a safe place for handy reference.
CV-10NH Operation Manual - Page 4

...INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS..., date of purchase, your complete mailing address (including zip code), your nearest Sharp Authorized Servicer) PARTS (for reporting loss or theft, please record below the model and...
CV-10NH Operation Manual - Page 5

...CV-10NH Portable Air Conditioner. This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below and provide proof of the nearest Sharp Authorized Servicer, call Sharp Toll Free at no event shall Sharp...of purchase. The limited warranty described herein is necessary to remove the Product, the Servicer will , at its option, ...
CV-10NH Operation Manual - Page 6

... cord must be replaced with the proper amp rating. Use of this room air conditioner should cause interference to radio or television reception, try to correct the interference... the receiving antenna. • Increase the separation between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into an appropriate wall socket. Only use a fuse with ...
CV-10NH Operation Manual - Page 7

...event of particularly adverse weather. Drained water may spill out while being moved. • Remove the window panel in the risk of an electric shock by providing a less resistant ...air conditioner. (See Page 26) If any circumstances cut or remove the round grounding pin from this plug. Extremely adverse weather may be plugged into the room. • Do not block the exhaust air...
CV-10NH Operation Manual - Page 8

... operation: Is your air conditioner work harder and less efficiently. When water tank inside the unit may cause the compressor to drain out water within three minutes, a protective device in the unit may frequently become full. Any previous settings will enter the room from the Exhaust air outlet, but this case, perform drainage...
CV-10NH Operation Manual - Page 9

... placed within reach of a properly rated grounded socket. • Never place any obstacles around the air inlet or outlet of space from the wall for direct installation.) E-7 For safe and secure positioning,...SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. ENGLISH LOCATION • The air conditioner should only be cut down in size because the window is too narrow for efficient...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 12

Side "A" will now be at the top, as indicated in the diagram. E-10 Cut Window panel Window stool net Side "A" will be at the top, as the window. (2)...indicated "A" in windows less than 22" (559mm) wide, as you will now be unable to shut the exhaust cover. (1) Remove the adjustment panel from the window panel, and cut the window panel to the window 22"~ 24" stool with 2 screws. If...
CV-10NH Operation Manual - Page 14

... window is installed in the window. INSTALL WINDOW PANEL Installation in a sliding sash window (See page 10 for installation in a double-hung window.) 1 Connect the rain guards to the window panel. Insect ... than 22" (559mm) high, as you will now be unable to shut the exhaust cover. (1) Remove the adjustment panel from the window panel, and cut the window panel to the window frame with 2 ...
CV-10NH Operation Manual - Page 16

...the top when it is installed in accordance with container(minimum capacity 31/2 gallons) Remove Installation of window exhaust adapter marked "TOP" should be as short as possible for ... container Install DEHUMIDIFICATION with the usage mode. three times) until it (approx. INSTALLATION AND REMOVAL OF EXHAUST HOSE The exhaust hose must not be twisted or bent. Make sure they are...
CV-10NH Operation Manual - Page 17

ENGLISH Removal of the exhaust hose 1 Remove the window exhaust adapter. Pull out and remove the window exhaust adapter by pushing down two "PUSH" markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit by pushing down on the two projections. "PUSH" Projection E-15 Lift up and remove the exhaust hose adapter from the unit.
CV-10NH Operation Manual - Page 18

... If you hear another CLICK. The circuit breaker is activated, power is supplied, and the air conditioner is functioning correctly. 4 Press the RESET button until you will appear on the display when ...using a thin pointed implement. Disconnect the power plug and call for a prolonged period, remove the batteries from the remote control. Battery cover NOTES: • The battery should last...
CV-10NH Operation Manual - Page 19

... it to block out the sunlight. • Use of a fluorescent lamp in the same room may interfere with transmission of the signal. • The unit may adversely affect its operation. If ...necessary, close the curtains to the unit when not in the same room. • Do not leave the remote control exposed to remove the remote control from moisture and shock which can discolor or damage ...
CV-10NH Operation Manual - Page 21

... the drainage nozzle. • Always perform this mode, the air conditioner dehumidifies the room. Operate dehumidification with a minimum capacity of 31/2... exhaust hose (See Page 14), turn off . In this case, drain out the water within the unit (See Page 26).... AUTO and cannot be set. • The fan speed is removed, a small amount of the water is started. Moreover, do ...
CV-10NH Operation Manual - Page 22

...FAN button to set the desired fan speed. • Although the louvers are closed and no air blows 3 out into the lower drainpipe nozzle and that the stopcock is covered with the stopcock... nozzle is securely inserted into the room, the external ventilation fan speed changes. E-20 VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. FAN MODE In...
CV-10NH Operation Manual - Page 24

... operation. TO CANCEL Press the CANCEL button. 1 • The orange TIMER lamp on the unit will turn off . MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish to protect the unit. Alternatively, turn the unit off by pressing the POWER button...
CV-10NH Operation Manual - Page 28

... drain out through the drainage hose. Hose band • This will take about one minute. 4 Remove the hose from the drainage nozzle, and replace the stopcock. • Keep the hose band and drain grommet in case of water that may be drained out is approximately 41/5 pints. • The OPERATION lamps will...
CV-10NH Operation Manual - Page 29

..., do not use harsh chemicals or abrasive cleaners on any part of the unit. 2 CLEAN THE FILTERS • Use a vacuum cleaner to remove any dust. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 26 "When the unit is clogged with dust, the...
CV-10NH Operation Manual - Page 30

...? It must not be drained. (See page26) • Check the power plug. (See page16) AIR CONDITIONER DOES NOT COOL PROPERLY • Is it set to FAN, DEHUMIDIFICATION or VENTILATION mode? For effi... batteries in these modes. Replace if necessary. • Try to minimize solar energy heating the room. • Is the exhaust hose too long? Close the curtains or blinds to send the...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.