Get support for Sanyo CM1972 - 19,700 BTU Ductless Multi-Split Air Conditioner

Sanyo CM1972 Support Question

Sanyo CM1972 Support Question

Find answers below for this question about Sanyo CM1972 - 19,700 BTU Ductless Multi-Split Air Conditioner.
Need a Sanyo CM1972 manual? We have 1 online manual for this item!
Question posted by andrestrumer on June 4th, 2018

Sanyo Cmh 3172 Thermistor

Hello,I need a replacement thermistor for my Sanyo CMH 3172.Please, advise.Thank you.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sanyo CM1972 Manual Pages

Service Manual - Page 1

... new refrigerant R410A. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 230V 19,700 BTU/h 25,400 BTU/h 30,600 BTU/h Outdoor Model No. Pay special attention when servicing the unit. CM1972 CM2472 CM3172 Product Code No. 1 852 330 27 1 852 330 28 1 852 330 29 CM1972 CM2472 < Applicable Indoor Units > ●Wall mounted type KMS0772 KMS0972...
Service Manual - Page 6

... × Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m3) < 230V > 3-Room Multi Outdoor Unit 3 3 230V Single-Phase 60Hz Cooling 19,700 ( 9,800 to 19,700 ) 5.80 ( 2.90 to 5.80 ) 16,800 2,900 1,707 (2,900) 187 to the "Unit Combination Tables" in performance section and electrical rating...
Service Manual - Page 7

... × Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m3) < 208V > 3-Room Multi Outdoor Unit 3 3 208V Single-Phase 60Hz Cooling 19,700 ( 9,800 to 19,700 ) 5.80 ( 2.90 to 5.80 ) 16,800 2,900 1,707 (2,900) 187 to the "Unit Combination Tables" in performance section and electrical rating...
Service Manual - Page 8

....7) × 1 Outdoor Unit 29-1/8 × 35-7/16 × 12-19/32 (740 × 900 × 320) 33-27/32 × ...cu.ft (m3) < 230V > 4-Room Multi Outdoor Unit 4 3 230V Single-Phase 60Hz...Air Circulation (High) Available Voltage Range Running Amperes Power Input Power Factor EER SEER Compressor Locked Rotor Amperes Fuse or Circuit Breaker Capacity BTU/h kW BTU/h BTU/h ft3/min (m3/h) V A W % BTU/h/W BTU...
Service Manual - Page 9

....7) × 1 Outdoor Unit 29-1/8 × 35-7/16 × 12-19/32 (740 × 900 × 320) 33-27/32 × ...Air Circulation (High) Available Voltage Range Running Amperes Power Input Power Factor EER SEER Compressor Locked Rotor Amperes Fuse or Circuit Breaker Capacity BTU/h kW BTU/h BTU/h ft3/min (m3/h) V A W % BTU/h/W BTU...cu.ft (m3) < 208V > 4-Room Multi Outdoor Unit 4 3 208V Single-Phase 60Hz...
Service Manual - Page 10

...Air Circulation (High) Available Voltage Range Running Amperes Power Input Power Factor EER SEER Compressor Locked Rotor Amperes Fuse or Circuit Breaker Capacity BTU/h kW BTU/h BTU/h ft3/min (m3/h) V A W % BTU/h/W BTU... × 2 Outdoor Unit 35-1/32 × 35-7/16 × 12-19/32 (890 × 900 × 320) 39-3/4 × 40-5/8 ....ft (m3) < 230V > 4-Room Multi Outdoor Unit 4 4 230V Single-Phase 60Hz...
Service Manual - Page 11

... × 2 Outdoor Unit 35-1/32 × 35-7/16 × 12-19/32 (890 × 900 × 320) 39-3/4 × 40-5/8 ....ft (m3) < 208V > 4-Room Multi Outdoor Unit 4 4 208V Single-Phase 60Hz...Air Circulation (High) Available Voltage Range Running Amperes Power Input Power Factor EER SEER Compressor Locked Rotor Amperes Fuse or Circuit Breaker Capacity BTU/h kW BTU/h BTU/h ft3/min (m3/h) V A W % BTU/h/W BTU...
Service Manual - Page 36

... Capacity Outdoor Unit : CM1972 Indoor Unit : KMS0972 × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: INDOOR ENT. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) D.B. / 67 °F (19.4 °C) W.B. : Outdoor Ambient Temp. 95 °F (35 °C) D.B. 2. D.B. 19,700 BTU/h 65 (18.3) TC 19,800 AIR FLOW RATE: OUTDOOR...
Service Manual - Page 37

...19.4 °C) W.B. : Outdoor Ambient Temp. 95 °F (35 °C) D.B. 2. For this reason, the value may vary from the actual cooling characteristics. 3. Above data does not take Freeze Prevention Protection during cooling operation into account. D.B. 25,400 BTU/h 65 (18.3) TC 25,690 AIR...110 23,110 24,180 13,010 15,930 17,700 17,700 17,700 18,070 67 (19.4) 72 (22.2) 76 (24.4) 80 (26.7) 84...
Service Manual - Page 38

...19.4 °C) W.B. : Outdoor Ambient Temp. 95 °F (35 °C) D.B. 2. Above data represents the value when the operation frequency of a compressor is fixed. 38 For this reason, the value may vary from the actual cooling characteristics. 3. D.B. 30,600 BTU/h 65 (18.3) TC 31,170 AIR... 23,980 28,010 28,010 28,010 28,010 29,310 21,700 22,960 22,960 22,960 22,960 23,400 16,690 16,...
Service Manual - Page 39

... Unit CM1972 To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts. 8FA2-5257-58800-1 39 REACTANCE BLK UNIT COMPRESSOR THERMISTOR BLK ...1234 CN01 MV2 12345 12345 W SICOM2 SI-C W ORG RED YEL BLK GRY CW THERMISTOR YEL YEL YEL YEL CN THERMISTOR 12345 12345 MV2 (2P)CONNECTOR 1 1 BLK 22 (2P)CONNECTOR WHT 11 WHT...
Service Manual - Page 41

... BLU 1234567 1234567 BRN WHT RED (PNK) WHT BLU R/V S/U C/W CM COMPRESSOR MOTOR FM FAN MOTOR HIGH PRESSURE SWITCH BLK BLK OVERLOAD RELAY(OLR) ORG DW THERMISTOR 12345678 123456 12345678 123456 CN03 CN02 EXPANSION BOARD D-TH C-TH MV3 1234 1234 12345 1234 1234 12345 1234 1234 CN01 MV2 12345 12345 W SICOM2 SI...
Service Manual - Page 50

...-unit cable Switch circuit board Outdoor control circuit board (1) Diode module HIC Electrolytic capacitor Fuse (2) Compressor (3) Compressor protective sensor (4) Outdoor fan motor Coil thermistor (5) Electric expansion valve (6) Branch tubing temperature sensor (7) Outdoor unit 50 Operation lamp blinking. Problems Indoor unit Inspection points Outdoor unit Others No...
Service Manual - Page 51

... to 8-3-1. of Inspection Points for an open circuit in the compressor coil winding. (4) Compressor protective sensor (compressor discharge temperature thermistor) Check that the senseor is securely contained in the thermostart holder. (5) Coil thermistor Check that the sensor is securely contained in the thermostat holder. 51 Operation lamp blinking. The compressor speed does...
Service Manual - Page 63

... © SANYO 2007 SANYO Commercial Solutions A Division of Outdoor Unit Installation 3. Type of Outdoor Unit 2-6. Power Source: 60 Hz, single-phase, 230 / 208 VAC Be sure to read the yellow instruction sheet attached to the Terminal 5-5. CONNECTING A HOME AUTOMATION DEVICE 26 The illustrations are installing. 8. Inverter Multi Split System Air Conditioner - Connecting...
Service Manual - Page 65

... 14. Manifold valve Figure Q'ty Parts 4 Reducer (1/2" 3/8") 1972 1 Figure Q'ty 2472 1 3172 2 Packed in this manual, please check for inter-unit cable and tube ABCD Reducer 4 each... cm) to purchase these materials separately from a local source, you will need: 1. Refer to install the air conditioning system. Accessories Supplied with Unit Table 1 Parts Figure Q'ty Parts Hex...
Service Manual - Page 73

... 20 25/64 5-29/32 25/32 10 150 20 R 25/32 20 25/32 20 For Air Discharge Dimensions A B C D E F Model CLM1972, 2472, (inch) 22-1/16 23-1/32 13-25/32 5-29/32 19-9/32 1-3/8 3172 (mm) 560 585 350 150 490 35 G H I J K 2-5/32 18-5/16 2-3/8 3-11/32 31/32 55 465 60...
Service Manual - Page 90

... of the outdoor unit. OI-85264180818004 © SANYO 2008 In addition to be connected. 2. CAUTION ...the following holds true Rated cooling capacity of CM1972 outdoor unit: C=19700 (BTU/h) Rated cooling capacity of indoor units: K1, K2, ... (BTU/h) Then: C x 2 (200%) K1...to the multi outdoor unit. at least one of the combinations found in trouble. Otherwise, the air conditioner may not...
Service Manual - Page 93

...multi...trouble. OI-85264180819004 © SANYO 2008 CAUTION In this case, ...BTU/h) Then: C x 2 (200%) K1 + K2 + ....... 24400 x 2 7500 + 7500 + 7500 + 17500 48800 40000 It is therefore possible to connect 4 units with only a single unit installed, the returning fluid to the combinations listed in trouble. Please be operated concurrently under any circumstances. Otherwise, the air conditioner...
Service Manual - Page 96

...air conditioner may not run properly and trouble may result in trouble. At a time like this, shut down at 208V If the following holds true Rated cooling capacity of CM3172 outdoor unit: C=28600 (BTU/h) Rated cooling capacity of indoor units: K1, K2, ... (BTU...rated cooling capacity of those units which can be connected to the multi outdoor unit. CAUTION In this sheet to the user. 4-Room ...

Similar Questions

Can The Fan On The Exterior Unit Be Replaced? My Fan Blade Has Fractured
can the fan blade be replaced on the exterior unit? Mod#CMH317
(Posted by gshecknauer 2 years ago)
Thermistor For My Sanyo Cmh 3172.
Hello, I need a thermistor for my Sanyo CMH 3172.Please, advise.Thank you.
(Posted by andrestrumer 6 years ago)
Looking For A 19 Volt Ac/dc Adapter Will Fit A Sanyo Clt205 Vizon Monitor
Where can I purchase a 19 volt ac/dc adapter will fit a sanyo CLT205 vizon monitor? Does it have to ...
(Posted by moza29291 8 years ago)
Ask a New Question
Use the box below to post a new question about this Sanyo product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sanyo Manuals

Find free Sanyo CM1972 - 19,700 BTU Ductless Multi-Split Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sanyo Reviews

View thousands of Sanyo user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sanyo customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sanyo customer service rankings, employee comments and much more from our sister site.

Sanyo Recalls

Find comprehensive Sanyo recall information updated hourly on RecallOwl.com.