Question posted by lanBurg on July 8th, 2014

Poweredge 2950 How To Use Baseboard Access Drac

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by JCatDell on July 9th, 2014 11:39 AM
This answer was accepted by the poster of the original question.
JCatDell

Member since:
March 11th, 2014

Points: 136,220
1,100
points
Hi IanBurg,

The baseboard management controller is not necessarily a DRAC, if you have a DRAC installed it adds the features to ctrl+E during POST for setting up the remote access IP address and then you can use a web browser to go to that IP and access the web GUI for the DRAC.


Josh Craig

Dell | Social Outreach Services - Enterprise
Get Support on Twitter @DellCaresPro

Related Dell PowerEdge 2950 Manual Pages

Installing a SATA Optical Drive - Page 4

... fit into place. If you must be replaced with the drive tray provided with the system is used for the SATA optical drive. See Figure 1-1. 5 Lower the left side of the optical drive to...drive. The pins on the interposer board release tab at the back of the tray. Replacing a PowerEdge 2950 or 2970 Optical Drive NOTE: If you are replacing an existing IDE optical drive, you are replacing...
Installing a SATA Optical Drive - Page 5

...to the old drive. Figure 1-1. Installing a SATA Optical Drive 5 Replacing the Optical Drive in a PowerEdge 2950 or 2970 System 2 1 3 4 5 6 7 1 optical drive 3 interposer 5 SATA power cable 7 optical drive carrier ...on the carrier align with the holes in the installation kit must be used with PowerEdge 1950 systems. If you are replacing an existing optical drive, do not reuse ...
Installing a SATA Optical Drive - Page 8

... bracket toward the front of the system until the bracket detaches from the chassis slots. 6 Route the SATA cable in the cable channel in the PowerEdge 2950 and 2970 1 2 3 4 5 1 SATA_B connector on the system board. See Figure 1-4. 7 Route the SATA cable along the top of the chassis and replace the cable retention...
Installing a SATA Optical Drive - Page 9

... SATA_B connector. - See Figure 1-5. - Installing a SATA Optical Drive 9 See Figure 1-5. - Installing the SATA Optical Drive - For a PowerEdge 1900 system, connect to the CD/TBU connector on the system and attached peripherals. For a PowerEdge 2900, use the SATA_D connector. See "Installing the Cooling Shroud" in your Hardware Owner's Manual. 11 Reconnect the system to...
Information Update - Page 1

Dell™ PowerEdge2950 Systems Information Update
Information Update - Page 3

... Features 5 New I/O and Storage Features 6 New Security Features 6 Optional Internal USB Memory Key 6 Installing the Optional Internal USB Memory Key 7 Support for 8-GB Memory Modules - PowerEdge 2950 III Systems 9 Processor Upgrades - Safeguarding Encrypted Data 9 System Message Update 10 LCD Status Messages Update 15 Contents 3 Contents Non-Optimal Memory Configurations...
Information Update - Page 5

...; Xeon® 5400 Series and 5300 Series processors. • 8-GB memory module support. Information Update 5 PowerEdge 2950 III - New High-Efficiency Power Supply and Power Monitoring Features • Higher system efficiency on power conversion across workloads. • Baseboard Management Control (BMC) power monitoring monitors current, voltage, and power utilization in the DIMM set...
Information Update - Page 9

...64 GB of memory is on your system. Safeguarding Encrypted Data On PowerEdge 2950 III systems using Windows Server® 2008, you can use encryption programs, such as the BitLocker utility, to the 5100 and... front of your system chassis is labeled with your system is fully supported. Power 2950 II and PowerEdge 2950 III Systems • If the front of your system chassis is labeled with a...
Information Update - Page 10

... are authorized to remove the system cover and access any of a possible problem with reduced information,...using the TPM with an encryption application, you can access the encrypted files on the screen to notify you of the components inside the computer, and protecting against electrostatic discharge. Be sure to store this recovery key. Table 1-1. Check (for the PowerEdge 2950...
Information Update - Page 15

See "Using the System Setup Program" in the Hardware Owner's Manual. Check the system event log for each message.... Text SYSTEM NAME FAILSAFE, Call Support CPU Temp Interface Causes Corrective Actions A 62-character string that can occur on the PowerEdge 2950 III system and the probable cause for critical failure events. Consequently, the BMC increases the CPU fan speed to the system...
Information Update - Page 21

... are not equipped with PXE, and Disabled. CAUTION: Before enabling the TPM Security option, ensure that use TCP by offloading part of embedded GB NIC2. System Security Screen Table 1-7 lists new options for applications...Technology (I /OAT reduces system CPU usage (Disabled default) for the PowerEdge 2950 III system. Table 1-6. Changes take effect after the system reboots.
Information Update - Page 24

System Diagnostics Update In the Customize window of operating systems on the Server OS Install tab. You cannot save the file to specify the diskette drive or USB memory key where the test log file ... is saved. System Support for Microsoft Windows 2000 If you to a hard drive. 24 Information Update This operating system is supported by the PowerEdge 2950 and 2950 II systems, but not by the...
Information Update - Page 27

目录 29 PowerEdge 2950 III 29 29 29 全新 I/O 30 30 内部 USB 30 USB 30 支持 8 GB PowerEdge 2950 III 32 PowerEdge 2950 II 和 PowerEdge 2950 III 32 32 33 LCD 37 40 Memory 40 CPU Information (CPU 42 Integrated Devices 42 System Security 44 Serial Communication 45 目录 27
Information Update - Page 29

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup (按 F1 F2 DIMM DIMM PowerEdge 2950 III 全新性能 Intel® Xeon® 5400 系列和 5300 8 GB BMC 信息更新 29
Information Update - Page 33

...26356;新 33 Node Interleaving disabled! DIMM !!*** Error: Remote Access Controller 化失败 initialization failure *** RAC virtual USB devices may not be available... Memory configuration does not support Node Interleaving. 表 1-1 列出了 PowerEdge 2950 III 表 1-1 信息 原因 纠正措...
Information Update - Page 44

...;导致 TPM TPM 密钥。 设置为 Yes TPM TPM Security (TPM Off 44 信息更新 System Security 表 1-7 PowerEdge 2950 III TPM。 TPM Security(TPM TPM。 表 1-7.
Information Update - Page 46

Microsoft Windows 2000 System Build and Update Utility Microsoft® Windows® 2000 将位于 Server OS Install PowerEdge 29502950 II PowerEdge 2950 III Customize Log output file pathname USB 46 信息更新
Information Update - Page 109

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup F1 F2 DIMM DIMM DIMM PowerEdge 2950 III Intel® Xeon® 5400 5300 2 個。 • 8 GB BMC 109
Information Update - Page 129

... Securit(y TPM Security Off) 説明 Trusted Platform Module(TPM Off TPM OS On with PXE(PXE Disabled PXE System Security PowerEdge 2950 III 1-7 TPM TPM Security(TPM OS が TPM 表 1-7. Integrated Devices Embedded Gb NIC2 Enabled without PXE) 説明 NIC Enabled without PXE...
Information Update - Page 142

... Node Interleaving disabled! Memory configuration does not support Node Interleaving. DIMM !!*** Error: Remote Access Controller initialization failure *** RAC virtual USB devices may not be available... RAC Invalid PCIe card found in the Internal_Storage slot! 표 1-1 PowerEdge 2950 III 표 1-1 메시지 원인 Alert!

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 2950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.