Page 3
ENEnGgLliIsShH CONTENTS Page FEATURES ...4 DISPLAY AND CROWNS/BUTTONS 5 DATE SETTING ...6 TIME SETTING ...7 ALARM ...8 STOPWATCH ...11 TACHYMETER ...14 ADJUSTING THE HAND POSITION 16 RESETTING THE BUILT-IN IC 17 BATTERY LIFE INDICATOR 18 BATTERY CHANGE ...18 TO PRESERVE THE QUALITY OF YOUR WATCH 19 SPECIFICATIONS ...23 3
ENEnGgLliIsShH CONTENTS Page FEATURES ...4 DISPLAY AND CROWNS/BUTTONS 5 DATE SETTING ...6 TIME SETTING ...7 ALARM ...8 STOPWATCH ...11 TACHYMETER ...14 ADJUSTING THE HAND POSITION 16 RESETTING THE BUILT-IN IC 17 BATTERY LIFE INDICATOR 18 BATTERY CHANGE ...18 TO PRESERVE THE QUALITY OF YOUR WATCH 19 SPECIFICATIONS ...23 3
Manual
Page 6
and 3:00 a.m. Otherwise, the date may not change properly. * If it is necessary to normal position. NOTES 1 Do not set the date and then reset the correct time. 2 It is necessary to set the date during that time period, first change the time to any time outside this period, set ...
and 3:00 a.m. Otherwise, the date may not change properly. * If it is necessary to normal position. NOTES 1 Do not set the date and then reset the correct time. 2 It is necessary to set the date during that time period, first change the time to any time outside this period, set ...
Manual
Page 11
CROWN 1 STOPWATCH 1/5 second hand CROWN 2 • Before using the stopwatch: • Check that CROWNS 1 and 2 are set at normal position. • Press Button B to reset STOPWATCH hands to "0" position. * If the hands do not return to "0" position, follow the procedure in 1/5 second increments. STOPWATCH OPERATION STOPWATCH minute hand B 30 A 25 10 MIN. q After 30 minutes, it will start counting again from "0" repeatedly up to 30 minutes in "ADJUSTING THE HAND POSITION" (page 16). 11 English 5 20 STOPWATCH q Stopwatch measures up to 6 hours.
CROWN 1 STOPWATCH 1/5 second hand CROWN 2 • Before using the stopwatch: • Check that CROWNS 1 and 2 are set at normal position. • Press Button B to reset STOPWATCH hands to "0" position. * If the hands do not return to "0" position, follow the procedure in 1/5 second increments. STOPWATCH OPERATION STOPWATCH minute hand B 30 A 25 10 MIN. q After 30 minutes, it will start counting again from "0" repeatedly up to 30 minutes in "ADJUSTING THE HAND POSITION" (page 16). 11 English 5 20 STOPWATCH q Stopwatch measures up to 6 hours.
Manual
Page 12
English B A 1 Standard measurement A START ˝ A STOP ˝ B RESET 2 Accumulated elapsed time measurement A ˝ A ˝ A ○○○ ˝ A ˝ B START STOP RESTART STOP RESET * Restart and stop of stopwatch can be repeated by pressing Button A. 3 Split time measurement A ˝ B ˝ B ○○○ ˝ A ˝ B START SPLIT SPLIT STOP RESET RELEASE 12 * Measurement and release of split time can be repeated by pressing Button B.
English B A 1 Standard measurement A START ˝ A STOP ˝ B RESET 2 Accumulated elapsed time measurement A ˝ A ˝ A ○○○ ˝ A ˝ B START STOP RESTART STOP RESET * Restart and stop of stopwatch can be repeated by pressing Button A. 3 Split time measurement A ˝ B ˝ B ○○○ ˝ A ˝ B START SPLIT SPLIT STOP RESET RELEASE 12 * Measurement and release of split time can be repeated by pressing Button B.
Manual
Page 13
English ˝ ˝ ˝ ˝ 4 Measurement of two competitors A START B FINISH TIME OF 1ST COMPETITOR A 2ND COMPETITOR FINISHES B FINISH TIME OF 2ND COMPETITOR B RESET NOTES 1 If CROWN 1 is pulled out to second click, STOPWATCH hands are reset to "0" position. 2 If CROWN 2 is pulled out to first or second click, STOPWATCH hands are reset to "0" position. 3 When stopwatch has been reset and Button A is pressed before the hands reach "0" position, stopwatch still starts counting when Button A is pressed. 13
English ˝ ˝ ˝ ˝ 4 Measurement of two competitors A START B FINISH TIME OF 1ST COMPETITOR A 2ND COMPETITOR FINISHES B FINISH TIME OF 2ND COMPETITOR B RESET NOTES 1 If CROWN 1 is pulled out to second click, STOPWATCH hands are reset to "0" position. 2 If CROWN 2 is pulled out to first or second click, STOPWATCH hands are reset to "0" position. 3 When stopwatch has been reset and Button A is pressed before the hands reach "0" position, stopwatch still starts counting when Button A is pressed. 13
Manual
Page 16
... 10 ADJUSTING THE HAND POSITION q If STOPWATCH hands will not return to the 12 o'clock position. Press repeatedly to reset STOPWATCH second hand to the 12 o'clock position when the stopwatch is reset or when the battery is replaced with a new one, follow the procedure below. Press repeatedly to... reset STOPWATCH minute hand to the 12 o'clock position. NOTES 1 Hands move quickly if the respective buttons are kept pressed. 2 ...
... 10 ADJUSTING THE HAND POSITION q If STOPWATCH hands will not return to the 12 o'clock position. Press repeatedly to reset STOPWATCH second hand to the 12 o'clock position when the stopwatch is reset or when the battery is replaced with a new one, follow the procedure below. Press repeatedly to... reset STOPWATCH minute hand to the 12 o'clock position. NOTES 1 Hands move quickly if the respective buttons are kept pressed. 2 ...
Manual
Page 17
B 30 A ˝ 25 10 MIN. « A B AND Press simultaneously. ˝ « CROWN 1 Push back in to second click. NOTE Before using the watch again, be sure to adjust the position of the hands should move improperly, follow the procedure below to adjust the hand movement. CROWN 1 CROWN 1 Pull out to normal position. English 5 20 RESETTING THE BUILT-IN IC q In case any of STOPWATCH hands and set the main time and alarm. 17
B 30 A ˝ 25 10 MIN. « A B AND Press simultaneously. ˝ « CROWN 1 Push back in to second click. NOTE Before using the watch again, be sure to adjust the position of the hands should move improperly, follow the procedure below to adjust the hand movement. CROWN 1 CROWN 1 Pull out to normal position. English 5 20 RESETTING THE BUILT-IN IC q In case any of STOPWATCH hands and set the main time and alarm. 17