Rheem 16AJL Support and Manuals

Get Help and Manuals for this Rheem item

View All Support Options Below
Free Rheem 16AJL manuals!
Problems with Rheem 16AJL?

Ask a Question

Most Recent Rheem 16AJL Questions

A Rp1748ajvca Unit And Have Had Problems In The Heat Mode.
The unit failed over 9 times last year. The outside unit was replaced and the failures continued. Th...
(Posted by CCLARK1976 5 years ago)
What Kind Of Rating Does This Unit Have Or Is It A Common Builders Unit
Please rate the rheem 16ajL36 unit 3ton.
(Posted by Tipsti 10 years ago)

Popular Rheem 16AJL Manual Pages

Brochure - Page 1

... performance backed by a 10-year conditional parts warranty. INTEGRATED HOME COMFORT Rheem.com Air Air Conditioners 16AJL Series reliability at an AFF RDABLE PRICE With the Rheem Value Series Two-Stage Air Conditioner, you get a higher level of comfort that every lifestyle deserves, and every budget can handle. 16AJL Series Efficiencies up to 16 SEER Reduced Energy Bills Two-stage cooling...
Brochure - Page 2

...make most of your equipment, installation, Protection Plus® extended service protection, maintenance agreements, and more about the plan that fit every budget so your cost to continually perform and deliver value for a copy of continuous progress & product improvement, Rheem reserves the right to 16 SEER. Our Protection Plus® extended service protection extends the coverage...
Specifications - Page 1

A11-210 Series Efficiencies up to 16 SEER/13 EER Nominal Sizes 2-5 Ton [7.03 to 17.6 kW] Cooling Capacities 25,400 to 57,000 BTU/H [7.44 to -read diagnostic alert codes • Painted louvered steel cabinet • Easily accessible control box • Condenser coils constructed with copper tubing and enhanced aluminum fins (2-4 Tons)/MicroChannel (5 Ton) • Grille/Motor mount...
Specifications - Page 3

Model Number Identification 16 A J 16 SEER A = AIR CONDITIONER VOLTAGE J = 208-230 SINGLE PHASE L DESIGN SERIES L = 1ST DESIGN R-410A Model I.D./Accessories/Compressor Air 16AJL Series 24 NOMINAL COOLING CAPACITY 24 = 24,000 BTU/HR ...scroll compressor is the key to efficiency for this Rheem model. For detailed thermostat match-up information, see specification sheet form number T11-001.
Specifications - Page 4

... 25400 [7.4] 24800 [7.3] 24800 [7.3] 525 [248] 700 [330] 16 13 0 [0] 0 [0] 575 [271] 15 12.5 800 [378] 575 [271] 15 12.5 800 [378] RGGE-07?MCK? Model Numbers ID Coil ID Air Mover Stage Net Sensible BTU/H [kW]...Capacity BTU/H [kW] SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RCSL-H*2621 ➀ RHML-HM2421 RGFE-06?MCK? Performance Data Air 16AJL Series Performance Data @ AHRI ...
Specifications - Page 5

Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- RGPE-05?BMK? 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] RGRM-04?MAE? 25800 [7.6] 16 13 2 18800 [5.5]...
Specifications - Page 6

... Ratings Latent BTU/H [kW] Total Capacity BTU/H [kW] SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RGGE-07?MCK? 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] RCFN-H*2421 ...10112; Highest sales volume tested combination required by D.O.E. Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit...
Specifications - Page 11

RGRM-10?ZAJ? Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- test procedures. 22300 [6.5] 8300 [2.4] 900 [425] 38500 [11.3] 16 13 28900 [8.5] 9600 [2.8] 1175 [554] 22300 [6.5] 8300 [2.4] 900 [425] 38500 [11.3] 16 13 28900 [8.5] 9600 [2.8] 1175 [554] Sound Rating dB 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77...
Specifications - Page 12

... 11.5 2 30600 [9.0] 14900 [4.4] 1400 [661] RGRM-10?ZAJ? RGFG-10?ZCM? Model Numbers ID Coil ID Air Mover Stage Net Sensible BTU/H [kW] AHRI Cooling Performance 80&#...[kW] SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RCFN-H*3624 ROLA-115E05 1 22300 [6.5] 8300 [2.4] 900 [425] 38500 [11.3] 16 13 2 ...16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit...
Specifications - Page 14

... 1400 [661] 1 26400 [7.7] 12100 [3.5] 1050 [495] 48500 [14.2] 16 12.5 2 34700 [10.2] 13800 [4.0] 1375 [649] 1 RGJF-09?ZCM? 2 1 RGJF-10?ZCM? 2 ➀ Highest sales volume tested combination required by D.O.E. Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- RGTM-09?ZAJ? 1 25200 [7.4] 12400 [3.6] 1125 [531] 46500 [13...
Specifications - Page 15

... 13800 [4.0] 1425 [672] RGTM-07?RBG? Model Numbers ID Coil ID Air Mover Stage Net Sensible ...SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RGJF-12?RCM? 1 26400 [7.7] 12100 [3.5] 1050 [495] 48500 [14.2] 16...16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- test procedures. 26200 [7.7] 12300 [3.6] 37000 [10.8] 12500 [3.7] 49500 [14.5] 1000 [472] 16...
Specifications - Page 16

... [767] 29600 [8.7] 14900 [4.4] 1150 [543] 56000 [16.4] 15 11 39200 [11.5] 16800 [4.9] 1600 [755] Sound Rating dB 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 [ ] Designates Metric Conversions 16 Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor...
Specifications - Page 17

... 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 [ ] Designates Metric Conversions 17 Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- RGTM-09?ZAJ? RGJF-10?ZCM? 1 30400 [8.9] 14600 [4.3] 1200 [566] 56500 [16.6] 15.5 11.5 2 39700 [11.6] 16800 [4.9] 1575 [743] 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000...
Specifications - Page 18

...16.8] 16 12 2 41500 [12.2] 16000 [4.7] 1700 [802] 1 RCSN-H*6024 RHPN-HM6024 2 ➀ Highest sales volume tested combination required by D.O.E. Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- Model...[kW] SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RGPE-07?BRQ? 1 30400 [8.9] 14600 [4.3] 1225 [578] 56500 [16.6] 15.5 11.5...
Specifications - Page 19

...Electrical and Physical Data Air 16AJL Series Electrical and Physical Data ELECTRICAL PHYSICAL Model Number 16AJL Phase Frequency (Hz) Voltage...kg] Lbs. [kg] 24 1-60-208/230 13/13 58.3 0.8 14/14 20/20 20/20 16.39 [1.52] 1 2805[1324] 105.4 [2988] 154 [69.9] 171 [69.9] 36 1-60-208... 15 feet of standard line set. [ ] Designates Metric Conversions 19 Ft. [m2] Rows CFM [L/s] Refrig. Sq.

Rheem 16AJL Reviews

Do you have an experience with the Rheem 16AJL that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Rheem yet.

Popular Rheem 16AJL Search Terms

The following terms are frequently used to search for Rheem 16AJL support:

Ask a New Question
Use the box below to post a new question about Rheem 16AJL.
Manuals / Documents
Download any of our Rheem 16AJL manuals for free!

We have the following 2 documents available for the Rheem 16AJL:
  • Specifications
  • Brochure
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem 16AJL manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem 16AJL user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.