NP115 : Environmental Whitepaper
Page 2
... line: • Do the products comply with these programs vary widely in aspect allows both nationally and globally, without notice. All specifications subject to operate and ultimately increase consumer taxes. NEC Corporation of hardware components is that old equipment has been properly recycled. From there, the materials are again separated and then...
... line: • Do the products comply with these programs vary widely in aspect allows both nationally and globally, without notice. All specifications subject to operate and ultimately increase consumer taxes. NEC Corporation of hardware components is that old equipment has been properly recycled. From there, the materials are again separated and then...
NP216 : NP01UCM (ceiling mount) instructions
Page 6
... are not intended for the concrete anchors. INCORRECT CORRECT metal bracket concrete metal bracket concrete plaster/ dry wall plaster/ dry wall Visit the NEC Web Site at www.necsam.com 6 of 50 lb (22.7 kg). IMPORTANT: It is unavoidable, plaster / drywall must be used...have a minimum of 1 5/8" of actual concrete surface in the 1/ 4" diameter hole to be 2000 psi density minimum. Concrete must meet ASTM C-90 specifications. • Concrete must be counterbored as shown in • lb (9 N.M.). • Make sure that the supporting surface will safely support the combined ...
... are not intended for the concrete anchors. INCORRECT CORRECT metal bracket concrete metal bracket concrete plaster/ dry wall plaster/ dry wall Visit the NEC Web Site at www.necsam.com 6 of 50 lb (22.7 kg). IMPORTANT: It is unavoidable, plaster / drywall must be used...have a minimum of 1 5/8" of actual concrete surface in the 1/ 4" diameter hole to be 2000 psi density minimum. Concrete must meet ASTM C-90 specifications. • Concrete must be counterbored as shown in • lb (9 N.M.). • Make sure that the supporting surface will safely support the combined ...
Ceiling Plate Technical Data Sheet
Page 1
... 1/2" NPT ("EXT" or "AEC" models) • Fixed length Extension Columns, 3/4" NPT (FLP Series)* *Must be used with a 1 1/2-11.5 NPS center threaded fitting and holes for outlet boxes (Raco 445 or Appleton 383 recommended) and antenna leads. The finish shall be done according to fine...Oak Circle. All other brand and product names are trademarks or registered trademarks of 2 MODEL: SCP200 ARCHITECTS SPECIFICATIONS The Lightweight Adjustable Suspended Ceiling Plate shall be a NEC model CMJ500R1 and shall be located where indicated on the plans. Features: • Includes Kwik-LocTM ...
... 1/2" NPT ("EXT" or "AEC" models) • Fixed length Extension Columns, 3/4" NPT (FLP Series)* *Must be used with a 1 1/2-11.5 NPS center threaded fitting and holes for outlet boxes (Raco 445 or Appleton 383 recommended) and antenna leads. The finish shall be done according to fine...Oak Circle. All other brand and product names are trademarks or registered trademarks of 2 MODEL: SCP200 ARCHITECTS SPECIFICATIONS The Lightweight Adjustable Suspended Ceiling Plate shall be a NEC model CMJ500R1 and shall be located where indicated on the plans. Features: • Includes Kwik-LocTM ...
V Series Specification Brochure
Page 2
... program to 3 years ECO Mode is a trademark, and DLP and the DLP logo are trademarks or registered trademarks of NEC Display Solutions. whichever comes first. Ordering Model Numbers NP-V260 NP-V260X NP-V300X Specifications for use with location control IN THE BOX Remote control, batteries, RGB cable, power cord, user's manual, product registration...
... program to 3 years ECO Mode is a trademark, and DLP and the DLP logo are trademarks or registered trademarks of NEC Display Solutions. whichever comes first. Ordering Model Numbers NP-V260 NP-V260X NP-V300X Specifications for use with location control IN THE BOX Remote control, batteries, RGB cable, power cord, user's manual, product registration...
RS232 codes- Projectors
Page 9
... fail to operate. Transfer speed: All speeds (supported) Endpoint: Control transfer Endpoint 0 Device class: HID class (Ver1.1) USB1.1 Standard: Universal Serial Bus Specification Revision 1.1 HID : Human Interface Device Connector Specifications 1 VBUS (Power supply) 2 D- (- USB connection This conforms to storing 02H : Exceeds the total number of blocks required at the time of start...
... fail to operate. Transfer speed: All speeds (supported) Endpoint: Control transfer Endpoint 0 Device class: HID class (Ver1.1) USB1.1 Standard: Universal Serial Bus Specification Revision 1.1 HID : Human Interface Device Connector Specifications 1 VBUS (Power supply) 2 D- (- USB connection This conforms to storing 02H : Exceeds the total number of blocks required at the time of start...
RS232 codes- Projectors
Page 26
... (*3) Data Portion Contents DATA01 05H fixed DATA02 Setting items 00H : Volume 01H : Bass 02H : Treble 03H : Balance DATA03 Setting mode 00H : Absolute value specification 01H : Relative value specification DATA04 DATA05 Setting Value (Lower ranking 8 bits) Setting Value (Upper ranking 8 bits) Response: At the time of a success 23H 10H 01H xxH 02H DATA01...
... (*3) Data Portion Contents DATA01 05H fixed DATA02 Setting items 00H : Volume 01H : Bass 02H : Treble 03H : Balance DATA03 Setting mode 00H : Absolute value specification 01H : Relative value specification DATA04 DATA05 Setting Value (Lower ranking 8 bits) Setting Value (Upper ranking 8 bits) Response: At the time of a success 23H 10H 01H xxH 02H DATA01...
RS232 codes- Projectors
Page 27
... .. DATA05 CKS (*3) Data Portion Contents DATA01 .. 02 Adjustment items DATA01 DATA02 Adjustment items 18H 00H Aspect Ratio Input (!) DATA03 Adjustment mode 00H : Absolute value specification 01H : Relative value specification DATA04 DATA05 Adjustment value (Lower ranking 8 bits) Adjustment value (Upper ranking 8 bits) Response: At the time of a success 23H 10H 01H xxH 02H...
... .. DATA05 CKS (*3) Data Portion Contents DATA01 .. 02 Adjustment items DATA01 DATA02 Adjustment items 18H 00H Aspect Ratio Input (!) DATA03 Adjustment mode 00H : Absolute value specification 01H : Relative value specification DATA04 DATA05 Adjustment value (Lower ranking 8 bits) Adjustment value (Upper ranking 8 bits) Response: At the time of a success 23H 10H 01H xxH 02H...
Installation Guide
Page 1
...V260/V260X/V300X Installation Guide Ceiling Mounted and Desktop Contents Product Description, Lens Specs, Notes and Formulas Diagrams & Distance Charts Cabinet Dimensions Ceiling Mount Dimensions Input Panels and Control Codes Pg 1 Pg 2 Pg 3-4 Pg 5 Pg 6 NEC Display... Description Type: 1-chip DLP projector, 0.55" DLP Résolution: V260: 800 x 600 V260X/V300X: 1024 x 768 Dimensions: 12.2" (W) x 3.7" (H) x 9.7" (D) Power Consumption: V260/V260X: 242W (max) V300X: 278W (max) Lens Specifications Throw Ratio: 1.9 - 2.1:1 (for 100" diagonal) Offset Angle: 12.8° - 14.0°...
...V260/V260X/V300X Installation Guide Ceiling Mounted and Desktop Contents Product Description, Lens Specs, Notes and Formulas Diagrams & Distance Charts Cabinet Dimensions Ceiling Mount Dimensions Input Panels and Control Codes Pg 1 Pg 2 Pg 3-4 Pg 5 Pg 6 NEC Display... Description Type: 1-chip DLP projector, 0.55" DLP Résolution: V260: 800 x 600 V260X/V300X: 1024 x 768 Dimensions: 12.2" (W) x 3.7" (H) x 9.7" (D) Power Consumption: V260/V260X: 242W (max) V300X: 278W (max) Lens Specifications Throw Ratio: 1.9 - 2.1:1 (for 100" diagonal) Offset Angle: 12.8° - 14.0°...