Linksys RTP300 - Broadband Router With 2 Phone Ports Support and Manuals

Get Help and Manuals for this Linksys item

View All Support Options Below
Free Linksys RTP300 manuals!
Problems with Linksys RTP300?

Ask a Question

Most Recent Linksys RTP300 Questions

How To Upgrade Firmware On Linksys Rtp300
(Posted by mitecboss 10 years ago)
Is The Skype Will Work With Rtp 300
is the skype will work with rtp 300?   Rajesh
(Posted by rajeshcth 11 years ago)
Wireless
is this router wireless can i go from room to room with my wireless lap top or phone  
(Posted by shamu242 11 years ago)

Linksys RTP300 Videos

Linksys RTP300
Duration: 1:49
Total Views: 427

Popular Linksys RTP300 Manual Pages

User Guide - Page 16

... ATA Administration Guide 16 The following table summarizes the ports and features provided by a "middle-man" server or media gateway controller. Provides ATA device functionality. 2 Wireless-G IP router with support for inbound call routing to trunk groups. 2 IP router with all functionality they plan to support before putting the Linksys ATA device in a VoIP service deployment are...
User Guide - Page 18

...Linksys ATA device are assigned by the Internet Telephony Service Provider (ITSP). The address and port are translated by the local router or the ISP router. The necessary routing can be provided by a router with hairpinning) or Broadband modem ISP LAN WAN Internet IP...1 Line 2 PAP2T Linksys ATA Administration Guide Ethernet port IP Router (with hairpinning support, or by an outbound SIP ...
User Guide - Page 39

... to the administration web server, and choose Admin access with Advanced settings. 2. Requirements: • You must have an external (public) IP address that is static. • The NAT mechanism used in the router must be symmetric. Click Voice tab > Line N, where N represents the line interface number. 5. Voice tab > Line N > NAT Settings Linksys ATA Administration Guide 39
User Guide - Page 44

...-32 • G.726-40 • G.729a • G.723 WRTP54G/RTP300 / WAG54GP2 • G.711u (configured by default, set your first, second, and third preferred codec. See "Linksys ATA Routing Field Reference," on page 61 Supported Codecs The following list shows the current supported codecs for voice services. • "Supported Codecs," on page 44 • "Using a FAX Machine (SPA2102, SPA3102...
User Guide - Page 74

... and can be used in the same way as a PSTN gateway, and the PSTN-To-VoIP calling function is assigned to support PSTN gateway calls exclusively. Linksys ATA Administration Guide 74 Line 1 does not provide a gateway because it provides only VoIP service. A different SIP port should be used for connectivity to configure the PSTN gateway provided...
User Guide - Page 75

... with a 503 response. The credentials are computed based on the Linksys ATA device. Configuring the PSTN (FXO) Gateway How VoIP-To-PSTN Calls Work VoIP callers can be authenticated by one of the following methods: • No Authentication-All callers are accepted for service. • PIN-Caller is prompted to enter a PIN right after...
User Guide - Page 77

.... Yes or No Linksys ATA Administration Guide 77 If PIN Authentication is enabled, it takes the FXO port on -hook. Yes or No The default is used again. NOTE: If Authentication is disabled, a default dial plan is Yes. On the other hand, when the Linksys ATA device receives a SIP BYE from the VoIP during a call legs...
User Guide - Page 83

... 0). Linksys ATA Administration Guide 83 The VoIP caller calls the FXO number, which auto-answers after the PIN is entered. The number dialed is in the user-id field of a auth-ID and password to PSTN Call With and Without Authentication This section describes three scenarios with HTTP digest authentication when the calling device supports...
User Guide - Page 89

... the DNS server: Manual (enter the IP address of the ATA device. The default is disabled, enter the primary DNS server. Router tab > WAN Setup page > MAC Clone Settings section A MAC address is used by the ATA device. Use when your ISP requires a certain MAC address. Linksys ATA Administration Guide 89 When DHCP is parallel. Default is 0.0.0.0. Some ISPs...
User Guide - Page 105

... RTP transmission and reception. SIP response status code to INVITE on ICMP errors. Number of successive ICMP errors allowed when transmitting RTP packets to play the SIT3 Tone. Valid values must be a multiple of 404 is returned, the SIT1 tone is 16384. The default is set the SIT1 RSC to 0, the ATA device ignores the...
User Guide - Page 112

... Ring9 Cadence Description Cadence script for the SPA2102 and SPA8000 only. Regional page VoIP PIN Tone Specification of the tone played to prompt a PSTN caller for distinctive ring 8. This setting applies to the SPA3102 only. The default is 60(.4/.2,.4/.2,.4/4). The default is 60(.8/.4,.8/4). Cadence script for a PIN number (if PIN authentication is for distinctive...
User Guide - Page 141

... • "VoIP-To-PSTN Gateway Setup section" section on page 149 • "VoIP Users and Passwords (HTTP Authentication) section" section on page 150 • "FXO (PSTN) Timer Values (sec) section" section on page 151 • "PSTN Disconnect Detection section" section on page 153 • "International Control (Settings) section" section on the list. The default is configured...
User Guide - Page 150

... for PSTN gateway service, regardless of the setting of the authentication method. Linksys ATA Administration Guide 150 The default is blank. The default is blank. The user assumes the identity of 8 Password VoIP User 1 must therefore compute the credentials using the HTTP Digest method (in other words, by a VoIP Caller, when the VoIP Caller Authentication Method parameter...
User Guide - Page 152

... the default is 5. The default is .1/.1. Linksys ATA Administration Guide 152 If VoIP peer does not reply or response is a SIP ReINVITE and the VoIP peer must response with up . PSTN-To-VoIP Call ... If value is set to 3.00. The range is 5. Unit is from the VoIP peer through the FXO port. The syntax is in seconds. 0 means unlimited. The default is 1. In...
User Guide - Page 199

Software Licenses: If this package is used in a product, Eric Young should be given attribution as the author of the parts of conditions and the following disclaimer. 2. Redistributions of source code must retain the copyright notice, this list of the library used are met: 1. The licence and distribution terms for any Windows specific code...OF SUBSTITUTE GOODS OR SERVICES; If you must ...

Linksys RTP300 Reviews

Do you have an experience with the Linksys RTP300 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Linksys yet.

Popular Linksys RTP300 Search Terms

The following terms are frequently used to search for Linksys RTP300 support:

Ask a New Question
Use the box below to post a new question about Linksys RTP300.
Manuals / Documents
Download any of our Linksys RTP300 manuals for free!

We have the following 1 documents available for the Linksys RTP300:
  • User Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Linksys Manuals

Find free Linksys RTP300 - Broadband Router With 2 Phone Ports manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Linksys Reviews

View thousands of Linksys RTP300 - Broadband Router With 2 Phone Ports user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Linksys customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Linksys customer service rankings, employee comments and much more from our sister site.