"Manufacturer's Certification for Credit" Manual
Page 1
... Qualifying for Credit LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412-1PKG) LiftMaster LA412 Solar Gate Operator System (Dual Gate Model LA412-2PKG) LiftMaster SW425DCSP3 Solar Gate Operator System LiftMaster RSL12V Residential DC Slide Gate Operator System ( Single gate model RSL12V) LiftMaster RSL12V Residential DC Slide Gate Operator System ( Dual gate model RSL12V) LiftMaster RSW12V Residential DC Swing Gate Operator System ( Single gate model RSW12V) LiftMaster RSW12V Residential DC Swing Gate Operator System ( Dual...
... Qualifying for Credit LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412-1PKG) LiftMaster LA412 Solar Gate Operator System (Dual Gate Model LA412-2PKG) LiftMaster SW425DCSP3 Solar Gate Operator System LiftMaster RSL12V Residential DC Slide Gate Operator System ( Single gate model RSL12V) LiftMaster RSL12V Residential DC Slide Gate Operator System ( Dual gate model RSL12V) LiftMaster RSW12V Residential DC Swing Gate Operator System ( Single gate model RSW12V) LiftMaster RSW12V Residential DC Swing Gate Operator System ( Dual...
Refer to the solar cycle chart for more details. Manual
Page 1
... power draw or Wireless Accessories are charged from solar chart for more than 2 consecutive weeks during the winter months. Solar panel(s) must be cleaned regularly to ensure proper operation. 3 4 3 4 Not Available Not Available 4 1 2 10W SOLAR 20W SOLAR 30W SOLAR 1 1 Number identifies zone. LA412 Solar Gate Access System Daily Cycle Chart The LA412 Solar Gate Access System utilizes the innovative EverCharge®...
... power draw or Wireless Accessories are charged from solar chart for more than 2 consecutive weeks during the winter months. Solar panel(s) must be cleaned regularly to ensure proper operation. 3 4 3 4 Not Available Not Available 4 1 2 10W SOLAR 20W SOLAR 30W SOLAR 1 1 Number identifies zone. LA412 Solar Gate Access System Daily Cycle Chart The LA412 Solar Gate Access System utilizes the innovative EverCharge®...
LA412 Manual
Page 1
LA412 & LA412-S 12 VOLT DC SOLAR RESIDENTIAL SWING GATE OPERATOR OWNER'S MANUAL MeBtOoLaaxplrtC(giXooennLMatrl)ol FOR RESIDENTIAL USE ONLY ■ Please read this manual and the enclosed safety materials carefully! ■ Periodic checks of the operator by a qualified technician are required to ensure safe operation. ■ The model number is located inside the control box of your operator. ■ Serial # ■ Installation date 2 YEAR WARRANTY
LA412 & LA412-S 12 VOLT DC SOLAR RESIDENTIAL SWING GATE OPERATOR OWNER'S MANUAL MeBtOoLaaxplrtC(giXooennLMatrl)ol FOR RESIDENTIAL USE ONLY ■ Please read this manual and the enclosed safety materials carefully! ■ Periodic checks of the operator by a qualified technician are required to ensure safe operation. ■ The model number is located inside the control box of your operator. ■ Serial # ■ Installation date 2 YEAR WARRANTY
LA412 Manual
Page 2
... 16 16 17-18 19 WIRING 20-24 Connect the Gate Operator (Gate 1) to the Control Box 20 Set the Lock/Bipart Delay (Model LA412-S Only) 21 Connect the Gate Operator (Gate 2) to the Control Box (Model LA412-S Only) 22 Junction Box (Model LA412-S Only) 23-24 SOLAR PANEL INSTALLATION ADJUSTMENT Limits Force Adjustment Timer-to-Close PROGRAMMING...
... 16 16 17-18 19 WIRING 20-24 Connect the Gate Operator (Gate 1) to the Control Box 20 Set the Lock/Bipart Delay (Model LA412-S Only) 21 Connect the Gate Operator (Gate 2) to the Control Box (Model LA412-S Only) 22 Junction Box (Model LA412-S Only) 23-24 SOLAR PANEL INSTALLATION ADJUSTMENT Limits Force Adjustment Timer-to-Close PROGRAMMING...
LA412 Manual
Page 5
...ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. • DO NOT use ONLY LiftMaster part 29-NP712 for replacement batteries. We recommend that time the unit may explode. SAFETY » IMPORTANT SAFETY INFORMATION INSTALLATION To ...and secured, at that you install an optional reversing edge BEFORE proceeding with local codes for a binding or sticking gate. • If one or more than 30W (3 solar panels). To AVOID damaging gas, power or other control may also need adjustment. • After ANY adjustments are...
...ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. • DO NOT use ONLY LiftMaster part 29-NP712 for replacement batteries. We recommend that time the unit may explode. SAFETY » IMPORTANT SAFETY INFORMATION INSTALLATION To ...and secured, at that you install an optional reversing edge BEFORE proceeding with local codes for a binding or sticking gate. • If one or more than 30W (3 solar panels). To AVOID damaging gas, power or other control may also need adjustment. • After ANY adjustments are...
LA412 Manual
Page 7
... will shorten the battery life. 14.5 Vac, 30 VA max. 16 feet at 550 lbs. -20° C to 50° C (-4° F to -Open Bracket Model LA412 (1) Model LA412-S (2) Gate Bracket Model LA412 (1) Model LA412-S (2) Post Bracket Model LA412 (1) Model LA412-S (2) 12V 10W Solar Panel Model SOLPNL10W12V (1) Cable Ties (4) Standard Control Box (1) with the hardware to install on...
... will shorten the battery life. 14.5 Vac, 30 VA max. 16 feet at 550 lbs. -20° C to 50° C (-4° F to -Open Bracket Model LA412 (1) Model LA412-S (2) Gate Bracket Model LA412 (1) Model LA412-S (2) Post Bracket Model LA412 (1) Model LA412-S (2) 12V 10W Solar Panel Model SOLPNL10W12V (1) Cable Ties (4) Standard Control Box (1) with the hardware to install on...
LA412 Manual
Page 9
... tripping, such as when a vehicle, trips the sensor while the gate is still moving. Warning Sign Gate Bracket tTpiPKDlehoEaimdyMsEeneiPeosonwttnirCvtlttiriLehIhataeEonnnncsuAgjctghaiRelt!umpiedrrusirGGsaofeyatrratoneteruaowos.vearepmereashnriiyCeaDcntlpaegmeea.rtsonaavhttoeeenClhagetyaanttauernasyonrece Hinge Post Bracket Operator Operator Cable Antenna Solar Panel (Facing South) Control Box with Batteries Solar Panel (Facing South) Hinge Post Bracket Gate Bracket PVC Conduit (not provided) to protect the power cable...
... tripping, such as when a vehicle, trips the sensor while the gate is still moving. Warning Sign Gate Bracket tTpiPKDlehoEaimdyMsEeneiPeosonwttnirCvtlttiriLehIhataeEonnnncsuAgjctghaiRelt!umpiedrrusirGGsaofeyatrratoneteruaowos.vearepmereashnriiyCeaDcntlpaegmeea.rtsonaavhttoeeenClhagetyaanttauernasyonrece Hinge Post Bracket Operator Operator Cable Antenna Solar Panel (Facing South) Control Box with Batteries Solar Panel (Facing South) Hinge Post Bracket Gate Bracket PVC Conduit (not provided) to protect the power cable...
LA412 Manual
Page 10
...nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving. 9 INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION DUAL GATE Solar Panel (Facing South) Antenna Warning Sign Hinge Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) ...228.f.4ft4e.metm) ) Earth Ground Installation (Optional) NOTE: One or more non-contact sensors shall be exercised to protect the power cable for solar and low voltage wire from lawn mowers and string trimmers.
...nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving. 9 INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION DUAL GATE Solar Panel (Facing South) Antenna Warning Sign Hinge Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) ...228.f.4ft4e.metm) ) Earth Ground Installation (Optional) NOTE: One or more non-contact sensors shall be exercised to protect the power cable for solar and low voltage wire from lawn mowers and string trimmers.
LA412 Manual
Page 20
... STOP CTRL PWR CTRL PWR SHADOW LOOP INPUTS INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY CLOSE EDGE OPEN EDGE/ PHOTO OPEN PHOTO... STOP CTRL PWR CTRL PWR SHADOW LOOP INPUTS INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY SET OPEN LIMIT G SET CLOSE LIMIT L L G FORCE...
... STOP CTRL PWR CTRL PWR SHADOW LOOP INPUTS INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY CLOSE EDGE OPEN EDGE/ PHOTO OPEN PHOTO... STOP CTRL PWR CTRL PWR SHADOW LOOP INPUTS INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY SET OPEN LIMIT G SET CLOSE LIMIT L L G FORCE...
LA412 Manual
Page 23
Solar Panel (Facing South) Control Box PTpDtKiMhlmeEoadiEyseneoPioeswnnttvCirtttliLiherhaIantEeonnncAusggcjhtRaumeiptl!GdeirursGriysaoeaaftrronteuteorwaoesmv.rapeereaChsnDryeiiacnaptmelgeean.oasrtahvottCeeehnaglaeytanutaternsayonerce Gate Operator (Gate 2) Junction Box Extension Cable PVC conduit at least 18" (45.7 cm) below ground level (grade) Gate Operator (Gate 1) 1 PVC conduit (not provided) to bury the extension cable. WIRING » CONNECT THE GATE OPERATOR (GATE 2) TO THE CONTROL BOX (MODEL LA412-S ONLY) CONNECT THE GATE OPERATOR (GATE 2) TO THE...
Solar Panel (Facing South) Control Box PTpDtKiMhlmeEoadiEyseneoPioeswnnttvCirtttliLiherhaIantEeonnncAusggcjhtRaumeiptl!GdeirursGriysaoeaaftrronteuteorwaoesmv.rapeereaChsnDryeiiacnaptmelgeean.oasrtahvottCeeehnaglaeytanutaternsayonerce Gate Operator (Gate 2) Junction Box Extension Cable PVC conduit at least 18" (45.7 cm) below ground level (grade) Gate Operator (Gate 1) 1 PVC conduit (not provided) to bury the extension cable. WIRING » CONNECT THE GATE OPERATOR (GATE 2) TO THE CONTROL BOX (MODEL LA412-S ONLY) CONNECT THE GATE OPERATOR (GATE 2) TO THE...
LA412 Manual
Page 26
The LA412 Solar Gate Operator is not supported in parallel to increase the number of cycles per day. This is based upon the average solar radiation and the temperature effects on gate construction and installation. Cycle rate may require additional solar panels. Ratings vary based on batteries ...in an open area clear of sunlight during the winter months. Solar panels cannot be installed in ...
The LA412 Solar Gate Operator is not supported in parallel to increase the number of cycles per day. This is based upon the average solar radiation and the temperature effects on gate construction and installation. Cycle rate may require additional solar panels. Ratings vary based on batteries ...in an open area clear of sunlight during the winter months. Solar panels cannot be installed in ...
LA412 Manual
Page 29
...SOLAR connector on the control board. 4 Tighten the watertight connector on the left-hand side of the control box. NOTES: Batteries will degrade over time depending on the control board. Battery Connectors 2 Battery Connection C1Ø1 R182 1 3ØA 32V LOCK D36 SOL GND MAGR D42 Z1 GATE...to be damaged. Batteries do not perform well in circuit by either an AC plug-in transformer or a separate solar panel, but not both. 1 Solar Panel Control Board 2 3 AC PWR/ SOLAR J4 Red 5 Black 4 6 6 Use the cable ties to verify the panel installation. Thread the cable ...
...SOLAR connector on the control board. 4 Tighten the watertight connector on the left-hand side of the control box. NOTES: Batteries will degrade over time depending on the control board. Battery Connectors 2 Battery Connection C1Ø1 R182 1 3ØA 32V LOCK D36 SOL GND MAGR D42 Z1 GATE...to be damaged. Batteries do not perform well in circuit by either an AC plug-in transformer or a separate solar panel, but not both. 1 Solar Panel Control Board 2 3 AC PWR/ SOLAR J4 Red 5 Black 4 6 6 Use the cable ties to verify the panel installation. Thread the cable ...
LA412 Manual
Page 37
....r For continued protection against fire: • Replace ONYL with fuse of same type and rating. 1. Open Edge/Photo 4. Loop Inputs 8. Gate 1 12. Timer To Close 23. OPTIONAL TRANSFORMER SOLAR PANEL NOTE: 14.5 V output on transformer. Lock (Solenoid/Maglock) Output 13. Learn Limits 20. Receiver Module 24. Antenna Input 2. AC... C11 U3 F7 Z4 D2 C13 D129 R42Ø R423 K6 F2 MOV1 C69 SHADOW INTERRUPT CHGR OVLD CTRL PWR R184 LOOP INPUTS AC PWR /SOLAR J18 P1 J2Ø * 2 EDGE * 3 50-220 SAFETY SENSORS EDGE OR * 4 50-220 SAFETY SENSORS * 5 50-220 SAFETY SENSORS OPEN (EXIT LOOP ) ...
....r For continued protection against fire: • Replace ONYL with fuse of same type and rating. 1. Open Edge/Photo 4. Loop Inputs 8. Gate 1 12. Timer To Close 23. OPTIONAL TRANSFORMER SOLAR PANEL NOTE: 14.5 V output on transformer. Lock (Solenoid/Maglock) Output 13. Learn Limits 20. Receiver Module 24. Antenna Input 2. AC... C11 U3 F7 Z4 D2 C13 D129 R42Ø R423 K6 F2 MOV1 C69 SHADOW INTERRUPT CHGR OVLD CTRL PWR R184 LOOP INPUTS AC PWR /SOLAR J18 P1 J2Ø * 2 EDGE * 3 50-220 SAFETY SENSORS EDGE OR * 4 50-220 SAFETY SENSORS * 5 50-220 SAFETY SENSORS OPEN (EXIT LOOP ) ...
LA412 Manual
Page 38
...• Battery may not be properly charged. Disconnect all batteries and make sure AC power or solar power is connected. Disconnect all batteries and make sure AC power or solar power is connected. Check the green and white wires on the control board. Stop is not ...8226; Batteries are intact and not blown. Dispose of old batteries properly. Check the green and white wires on either Gate 1 or 2, replace the arm. 8 FLASHES FORCE REVERSAL GATE 2 Gate 2 has encountered an obstruction. • Make sure the path of the battery. Normal Operation. Replace the batteries (...
...• Battery may not be properly charged. Disconnect all batteries and make sure AC power or solar power is connected. Disconnect all batteries and make sure AC power or solar power is connected. Check the green and white wires on the control board. Stop is not ...8226; Batteries are intact and not blown. Dispose of old batteries properly. Check the green and white wires on either Gate 1 or 2, replace the arm. 8 FLASHES FORCE REVERSAL GATE 2 Gate 2 has encountered an obstruction. • Make sure the path of the battery. Normal Operation. Replace the batteries (...
LA412 Manual
Page 39
... the STOP LED lights up and then turns off after 10 seconds. Adjust arm mounting and positioning if necessary. • Arm is interfering with both gates swing easily. Disconnect the arms and verify that all 4 screws are connected properly. • Motor housing is below 11.5 Vdc. • Bad ...point where the arm mounts to verify operator will respond. • Bad control board. Verify battery fuse is obstructed. Make sure the AC/Solar input is connected and that the STOP LED lights up and then turns off after 10 seconds. Check battery connections and battery voltage to be...
... the STOP LED lights up and then turns off after 10 seconds. Adjust arm mounting and positioning if necessary. • Arm is interfering with both gates swing easily. Disconnect the arms and verify that all 4 screws are connected properly. • Motor housing is below 11.5 Vdc. • Bad ...point where the arm mounts to verify operator will respond. • Bad control board. Verify battery fuse is obstructed. Make sure the AC/Solar input is connected and that the STOP LED lights up and then turns off after 10 seconds. Check battery connections and battery voltage to be...
LA412 Manual
Page 41
...Bracket 1 2 K23-19380 Reset Switch 1 7 3 K74-34392 Antenna 1 4 29-NP712 Battery 1 5 K76-19446 Alarm 1 4 5 6 SOLPNL10W12V Solar Panel 2 Not Shown LA412-CONT Complete Control Box K1A6636 Receiver Module - 315 MHz K1A6636-1 Receiver Module - 390 MHz (optional) 1 K76-35600 Reset Switch (XLM Control Box) ... Key 1 K77-19130 Hardware Bag Complete with your operator. If optional modifications and/or accessories are included with : Gate bracket, post bracket, pull-to the parts lists below for replacement parts available for your operator, certain components may ...
...Bracket 1 2 K23-19380 Reset Switch 1 7 3 K74-34392 Antenna 1 4 29-NP712 Battery 1 5 K76-19446 Alarm 1 4 5 6 SOLPNL10W12V Solar Panel 2 Not Shown LA412-CONT Complete Control Box K1A6636 Receiver Module - 315 MHz K1A6636-1 Receiver Module - 390 MHz (optional) 1 K76-35600 Reset Switch (XLM Control Box) ... Key 1 K77-19130 Hardware Bag Complete with your operator. If optional modifications and/or accessories are included with : Gate bracket, post bracket, pull-to the parts lists below for replacement parts available for your operator, certain components may ...
LA412 Manual
Page 43
...50-19503 Wireless Gate Doorbell: Allows guests to operate gate operator from inside the home using a 4-digit code. 29-NP712 A12330SGLPK SECURITY✚® Keyless Entry: Enables homeowner to ring a doorbell iOnPENthe house from the keypad. To order visit www.liftmaster.com 42 OPEN...free exit only. CLOSE 7 AH/12 Vdc Gate Access System Battery: The gate access system battery is closed. GPINLCK OPEN CLOSE 3-Button Mini-Remote Control with gate, providing for solar applications or as a replacement battery. The model LA412 is designed to use two 7AH batteries or ...
...50-19503 Wireless Gate Doorbell: Allows guests to operate gate operator from inside the home using a 4-digit code. 29-NP712 A12330SGLPK SECURITY✚® Keyless Entry: Enables homeowner to ring a doorbell iOnPENthe house from the keypad. To order visit www.liftmaster.com 42 OPEN...free exit only. CLOSE 7 AH/12 Vdc Gate Access System Battery: The gate access system battery is closed. GPINLCK OPEN CLOSE 3-Button Mini-Remote Control with gate, providing for solar applications or as a replacement battery. The model LA412 is designed to use two 7AH batteries or ...