Forms and Bar Code Technical Reference
Page 56
... header (for example, [)>RS01GSyy) can be produced within specific row, column and error correction codeword combinations, up to 6 alphanumeric characters (any printable character in AIM spec). For modes 4, 5, and 6, the message follows the number-of four data columns by 44 rows. Mode 4, separated with commas: ESC&y48W1,1,ABC01,840,001,This...
... header (for example, [)>RS01GSyy) can be produced within specific row, column and error correction codeword combinations, up to 6 alphanumeric characters (any printable character in AIM spec). For modes 4, 5, and 6, the message follows the number-of four data columns by 44 rows. Mode 4, separated with commas: ESC&y48W1,1,ABC01,840,001,This...
Forms and Bar Code Technical Reference
Page 91
values are /Model1, /Model2 (default); values are /300ths, /600ths, /1200ths; has the same meaning as defined in AIM spec). Postal codes greater than 9 digits will be 0 to 6 alphanumeric characters (any printable character in length, padded with leading zeros, if necessary. • The class of -...
values are /Model1, /Model2 (default); values are /300ths, /600ths, /1200ths; has the same meaning as defined in AIM spec). Postal codes greater than 9 digits will be 0 to 6 alphanumeric characters (any printable character in length, padded with leading zeros, if necessary. • The class of -...
Forms and Bar Code Technical Reference
Page 156
... the exact same way as Code 39. This will also be uppercase, reflecting the actual data within the bar code itself is operating per the specs at the URLs noted above. Due to the BCE. However, the HRT start and stop characters are either different than the actual bar code encoded... code engine is printed as lowercase, reflecting the input data, rather than the HP BarDIMM Pro version 3.3A1 (referred to as "HP BDP"), or the Lexmark Bar Code Card version 2.5. (referred to as "BCE" in this section. Therefore, the Forms and Bar Code Card firmware must convert any code 93 lowercase...
... the exact same way as Code 39. This will also be uppercase, reflecting the actual data within the bar code itself is operating per the specs at the URLs noted above. Due to the BCE. However, the HRT start and stop characters are either different than the actual bar code encoded... code engine is printed as lowercase, reflecting the input data, rather than the HP BarDIMM Pro version 3.3A1 (referred to as "HP BDP"), or the Lexmark Bar Code Card version 2.5. (referred to as "BCE" in this section. Therefore, the Forms and Bar Code Card firmware must convert any code 93 lowercase...
Forms and Bar Code Technical Reference
Page 157
... amount of encoding data. The BCE is just a guide, not an absolute definition of capability, and could change upward or downward depending on a per the specs noted above, and does not translate lowercase to garbled images. The practical commercially viable limit for a requested bar code on these assumptions: • the amount...
... amount of encoding data. The BCE is just a guide, not an absolute definition of capability, and could change upward or downward depending on a per the specs noted above, and does not translate lowercase to garbled images. The practical commercially viable limit for a requested bar code on these assumptions: • the amount...
Forms and Bar Code Technical Reference
Page 161
... of 4 bytes that are: • A number 1 through 8, that examines input data: • Byte 5 for a separator character If they do not fully implement it. The HP spec BarDIMM specification version 3.0 (and all versions from 3.0 onward are no bar code readers that is specified. Gs: hex 1D, decimal 29 comma: hex 2C, decimal...
... of 4 bytes that are: • A number 1 through 8, that examines input data: • Byte 5 for a separator character If they do not fully implement it. The HP spec BarDIMM specification version 3.0 (and all versions from 3.0 onward are no bar code readers that is specified. Gs: hex 1D, decimal 29 comma: hex 2C, decimal...