Service Guide
Page 4
... Specifications 58 CEC Drawer 58 7014 Model T00 and T42 Rack 60 I /O Drawer, Operator Panel Power Present LED Does Not Come On 104 iv Service Guide Riser Card Memory Placement Rules 26 I/O Drawer Features 27 I/O Drawer Addressing 27 I/O Drawer and Power Supply LED Status 28 Message Hierarchy for the pSeries and RS/6000...
... Specifications 58 CEC Drawer 58 7014 Model T00 and T42 Rack 60 I /O Drawer, Operator Panel Power Present LED Does Not Come On 104 iv Service Guide Riser Card Memory Placement Rules 26 I/O Drawer Features 27 I/O Drawer Addressing 27 I/O Drawer and Power Supply LED Status 28 Message Hierarchy for the pSeries and RS/6000...
Service Guide
Page 9
...an S00 Type Rack 526 Rails for Using the Generic Sample Modem Configuration Files . . . . 503 Customizing the Modem Configuration Files 504 IBM 7852-400 DIP Switch Settings 505 Xon/Xoff Modems 505 Ring Detection 506 Terminal Emulators 506 Recovery Procedures 506 Transfer of a Modem Session ... Sample File modem_z0.cfg 515 Sample File modem_f.cfg 517 Sample File modem_f0.cfg 519 Sample File modem_f1.cfg 521 Appendix E. Specific Modem Configuration Files 501 Configuration File Selection 502 Examples for a T00 Type Rack 526 Rail Installation 526 Cable Routing 527 Index 531 Contents...
...an S00 Type Rack 526 Rails for Using the Generic Sample Modem Configuration Files . . . . 503 Customizing the Modem Configuration Files 504 IBM 7852-400 DIP Switch Settings 505 Xon/Xoff Modems 505 Ring Detection 506 Terminal Emulators 506 Recovery Procedures 506 Transfer of a Modem Session ... Sample File modem_z0.cfg 515 Sample File modem_f.cfg 517 Sample File modem_f0.cfg 519 Sample File modem_f1.cfg 521 Appendix E. Specific Modem Configuration Files 501 Configuration File Selection 502 Examples for a T00 Type Rack 526 Rail Installation 526 Cable Routing 527 Index 531 Contents...
Service Guide
Page 17
... 660 Models 6H0 Eserver and 6H1 may be installed. About This Book This book provides maintenance information that is specific to the RS/6000 Enterprise Server Model H80, pSeries 660 Models 6H0 and 6H1, as well as the ″system.″ This book also contains Maintenance... To access the online books, visit our Web site at: http://www.rs6000.ibm.com/resource/hardware_docs/ Related Publications The following publications are available online. v The RS/6000 Enterprise Server Model H80 pSeries 660 Models 6H0 and Eserver 6H1 Installation Guide, order number SA38-0575, ...
... 660 Models 6H0 Eserver and 6H1 may be installed. About This Book This book provides maintenance information that is specific to the RS/6000 Enterprise Server Model H80, pSeries 660 Models 6H0 and 6H1, as well as the ″system.″ This book also contains Maintenance... To access the online books, visit our Web site at: http://www.rs6000.ibm.com/resource/hardware_docs/ Related Publications The following publications are available online. v The RS/6000 Enterprise Server Model H80 pSeries 660 Models 6H0 and Eserver 6H1 Installation Guide, order number SA38-0575, ...
Service Guide
Page 50
... Guide The base location identifies a device that is connected to provide mapping of cables attached to serial port 1. v P1-K1 identifies a keyboard attached to their specific locations within the physical structure of the parent, a connector, or a cable. Location codes with AIX location codes to or plugged into planar P1. Physical Location...
... Guide The base location identifies a device that is connected to provide mapping of cables attached to serial port 1. v P1-K1 identifies a keyboard attached to their specific locations within the physical structure of the parent, a connector, or a cable. Location codes with AIX location codes to or plugged into planar P1. Physical Location...
Service Guide
Page 76
... cooling, power supply, and environmental requirements for the CEC drawer are provided for the system. Specifications This section contains specifications for CEC drawer, rack, and the I/O drawer specifications. Individual sections are shown in the following table: Dimensions Height Width Depth Weight Minimum configuration Maximum...² Humidity Noncondensing Without tape drive With tape drive Wet Bulb Requirements Without tape drive With tape drive Noise Emissions³ With H80 CEC Drawer only LWAd LpAm m Impulsive or prominent discrete tones 218 mm 8.58 in. (5 EIA Units) 445 mm 17.5...
... cooling, power supply, and environmental requirements for the CEC drawer are provided for the system. Specifications This section contains specifications for CEC drawer, rack, and the I/O drawer specifications. Individual sections are shown in the following table: Dimensions Height Width Depth Weight Minimum configuration Maximum...² Humidity Noncondensing Without tape drive With tape drive Wet Bulb Requirements Without tape drive With tape drive Noise Emissions³ With H80 CEC Drawer only LWAd LpAm m Impulsive or prominent discrete tones 218 mm 8.58 in. (5 EIA Units) 445 mm 17.5...
Service Guide
Page 78
DC only Width without side panels With side panels Depth with rear door RS/6000 T00 with both doors pSeries T00 with both doors 1804 mm 71.0 in. 36 EIA Units 1926 mm 75.8 in. 623 mm 24.5 in. 644 ... 816 kg 1795 lbs . (sum specified values for drawers or enclosures in rack) 8.4 4.8 200 to 240 50 or 60 Temperature Requirements (see specifications for drawers or enclosures) Humidity Requirements (see specifications for drawers or enclosures) Noise Emissions (see specifications for the rack are shown in the following table: Dimensions Height Capacity With PDP -
DC only Width without side panels With side panels Depth with rear door RS/6000 T00 with both doors pSeries T00 with both doors 1804 mm 71.0 in. 36 EIA Units 1926 mm 75.8 in. 623 mm 24.5 in. 644 ... 816 kg 1795 lbs . (sum specified values for drawers or enclosures in rack) 8.4 4.8 200 to 240 50 or 60 Temperature Requirements (see specifications for drawers or enclosures) Humidity Requirements (see specifications for drawers or enclosures) Noise Emissions (see specifications for the rack are shown in the following table: Dimensions Height Capacity With PDP -
Service Guide
Page 84
The cable set should be installed and should have the appropriate safety approvals for the specific countries where they are available. 66 Service Guide Power cables used in other countries consist of the following : v Electrical cables, Type SVT or SJT v Attachment ...
The cable set should be installed and should have the appropriate safety approvals for the specific countries where they are available. 66 Service Guide Power cables used in other countries consist of the following : v Electrical cables, Type SVT or SJT v Attachment ...
Service Guide
Page 178
... Information for Eserver Multiple Bus Systems. 160 Service Guide Check SCSI cabling. 3. b. Disconnect the disk drive(s) in the RS/6000 and Eserver pSeries Diagnostics Information for Multiple Bus Systems. 2. Disconnect the signal and power cables from any other SCSI devices ...another attached SCSI device is not listed, go to perform an operating system-specific recovery process, or reinstall the operating system. It is reported, go to ″MAP 410: Repair Checkout″ in the RS/6000 and pSeries Diagnostics Information for Multiple Bus Systems manual. 3. e. If an...
... Information for Eserver Multiple Bus Systems. 160 Service Guide Check SCSI cabling. 3. b. Disconnect the disk drive(s) in the RS/6000 and Eserver pSeries Diagnostics Information for Multiple Bus Systems. 2. Disconnect the signal and power cables from any other SCSI devices ...another attached SCSI device is not listed, go to perform an operating system-specific recovery process, or reinstall the operating system. It is reported, go to ″MAP 410: Repair Checkout″ in the RS/6000 and pSeries Diagnostics Information for Multiple Bus Systems manual. 3. e. If an...
Service Guide
Page 184
... the system has attempted to as Greenwich mean time.) On this system, the error code displayed in the primary drawer op panel may not be specific fault information in the service processor error log. To get a list of the problem. If the system is at the top of errors codes (which...
... the system has attempted to as Greenwich mean time.) On this system, the error code displayed in the primary drawer op panel may not be specific fault information in the service processor error log. To get a list of the problem. If the system is at the top of errors codes (which...
Service Guide
Page 374
... firmware update invalid Call service support B1xx 0013 A firmware update has failed because Install a valid firmware image for the the update image is invalid. The specific type and model. Table 8. Common Firmware Error Codes (continued) Error Code Description Action/ Possible Failing FRU B10F 1370 Service processor flash update failure 1. Update system...
... firmware update invalid Call service support B1xx 0013 A firmware update has failed because Install a valid firmware image for the the update image is invalid. The specific type and model. Table 8. Common Firmware Error Codes (continued) Error Code Description Action/ Possible Failing FRU B10F 1370 Service processor flash update failure 1. Update system...
Service Guide
Page 380
... service processor (by disconnecting, then reconnecting changes were made to "MAP 1540: Minimum Configuration" on page 113, CEC minimum config 3. Primary I /O interface 1. Check for the specific system type and model. 362 Service Guide Primary I /O backplane Location: U0.1-P1 B1xx 469E Service processor firmware failure 1. Go to I /O backplane Location: U0.1-P1 B1xx...
... service processor (by disconnecting, then reconnecting changes were made to "MAP 1540: Minimum Configuration" on page 113, CEC minimum config 3. Primary I /O interface 1. Check for the specific system type and model. 362 Service Guide Primary I /O backplane Location: U0.1-P1 B1xx 469E Service processor firmware failure 1. Go to I /O backplane Location: U0.1-P1 B1xx...
Service Guide
Page 381
Replace the diskette drive. 3. When the scan log dump is correct for the specific system type and model 2. Table 8. B1FD 0016 Diskette read error 1. The firmware diskette may reboot, depending on the reboot policy settings. As the dump progresses, ...
Replace the diskette drive. 3. When the scan log dump is correct for the specific system type and model 2. Table 8. B1FD 0016 Diskette read error 1. The firmware diskette may reboot, depending on the reboot policy settings. As the dump progresses, ...
Service Guide
Page 412
... have that number, leave this field unassigned. v Digital Pager Telephone Number is the telephone number of the preceding three telephone numbers must be assigned in a specific format to which your administration center representative for the correct telephone number to as the call -out capability. The service or administration center representatives need...
... have that number, leave this field unassigned. v Digital Pager Telephone Number is the telephone number of the preceding three telephone numbers must be assigned in a specific format to which your administration center representative for the correct telephone number to as the call -out capability. The service or administration center representatives need...
Service Guide
Page 414
.... Customer RETAIN login password: Currently Unassigned 98. Otherwise, leave this field unassigned. Customer Account Setup Menu This menu allows users to enter information that is specific to the customer settings. 396 Service Guide If you have access. Customer Account Setup Menu 1. Return to which your service provider may or may not...
.... Customer RETAIN login password: Currently Unassigned 98. Otherwise, leave this field unassigned. Customer Account Setup Menu This menu allows users to enter information that is specific to the customer settings. 396 Service Guide If you have access. Customer Account Setup Menu 1. Return to which your service provider may or may not...
Service Guide
Page 422
... failure can be reflashed. Insert update diskette 3. A processor or memory DIMM is displayed at any time during the process, the service processor must be isolated specifically to manually deconfigure a processor or memory DIMM, or re-enable a previously deconfigured processor or memory DIMM. Insert update diskette n. The Repeat Gard function also allows...
... failure can be reflashed. Insert update diskette 3. A processor or memory DIMM is displayed at any time during the process, the service processor must be isolated specifically to manually deconfigure a processor or memory DIMM, or re-enable a previously deconfigured processor or memory DIMM. Insert update diskette n. The Repeat Gard function also allows...
Service Guide
Page 425
... the service processor to retry, continuing to enabled from another modem. v Enter the modem configuration file name. Using the Service Processor 407 v Set up site-specific parameters (phone numbers for call-out, call out before restart, set Call-out before restart to place pager calls for the paging function. Note: Some...
... the service processor to retry, continuing to enabled from another modem. v Enter the modem configuration file name. Using the Service Processor 407 v Set up site-specific parameters (phone numbers for call-out, call out before restart, set Call-out before restart to place pager calls for the paging function. Note: Some...
Service Guide
Page 511
... lead acid, nickel cadmium, nickel metal hydride, and other battery packs from IBM Equipment. Before this system signify IBM's commitment to applicable regulations. IBM offers product-return programs in manufacturing wastes. In the United States, IBM has established a collection process for specific battery information. Environmental Design The environmental efforts that require special handling and disposal...
... lead acid, nickel cadmium, nickel metal hydride, and other battery packs from IBM Equipment. Before this system signify IBM's commitment to applicable regulations. IBM offers product-return programs in manufacturing wastes. In the United States, IBM has established a collection process for specific battery information. Environmental Design The environmental efforts that require special handling and disposal...
Service Guide
Page 519
... modem_z.cfg modem_z0.cfg modem_f.cfg modem_f0.cfg modem_f1.cfg Service Processor Firmware File Name modem_z_sp modem_z0_sp modem_f_sp modem_f0_sp modem_f1_sp Specific Modem Configuration Files AIX File Name modem_m0.cfg modem_m1.cfg Service Processor Firmware File Name modem_m0_sp modem_m1_sp Use the following ...names. Modem Configurations The service processor is designed to determine which of each specific file is included in the /usr/share/modems subdirectory (if your system / server is suitable for a custom setup. ...
... modem_z.cfg modem_z0.cfg modem_f.cfg modem_f0.cfg modem_f1.cfg Service Processor Firmware File Name modem_z_sp modem_z0_sp modem_f_sp modem_f0_sp modem_f1_sp Specific Modem Configuration Files AIX File Name modem_m0.cfg modem_m1.cfg Service Processor Firmware File Name modem_m0_sp modem_m1_sp Use the following ...names. Modem Configurations The service processor is designed to determine which of each specific file is included in the /usr/share/modems subdirectory (if your system / server is suitable for a custom setup. ...
Service Guide
Page 525
... on your server's modem. Consult your modem manual for the &Dn command. If Yes, this is set up correctly. See your modem manual for its specific response scheme for this information. This then breaks the connection. Using this mechanism, the server hangs up correctly. If No, try another &Dn setting for...
... on your server's modem. Consult your modem manual for the &Dn command. If Yes, this is set up correctly. See your modem manual for its specific response scheme for this information. This then breaks the connection. Using this mechanism, the server hangs up correctly. If No, try another &Dn setting for...
Service Guide
Page 527
... Files Sample File modem_m0.cfg # # COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP: modem_m0 # # FUNCTIONS: Modem configuration file specifically for Catcher calls. Use, duplication or # disclosure restricted by GSA ADP Schedule Contract with Auto-Reliable feature. expect "33\r" or...Reliable mode # Echo off # Ignore modem response. # Disable pacing # Disable data compression # Confirm commands successful. # DSR independent of IBM # # US Government Users Restricted Rights - This feature must be set to # choose the factory defaults. # # (C) COPYRIGHT International Business...
... Files Sample File modem_m0.cfg # # COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP: modem_m0 # # FUNCTIONS: Modem configuration file specifically for Catcher calls. Use, duplication or # disclosure restricted by GSA ADP Schedule Contract with Auto-Reliable feature. expect "33\r" or...Reliable mode # Echo off # Ignore modem response. # Disable pacing # Disable data compression # Confirm commands successful. # DSR independent of IBM # # US Government Users Restricted Rights - This feature must be set to # choose the factory defaults. # # (C) COPYRIGHT International Business...