... OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Push up to be installed over a tub or shower, it can be connected to the receptacle). Before servicing or cleaning the unit, switch power off power unit. 3. Installation work and electrical wiring must not be done by the manufacturer. Unit must be installed in a wall. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. To avoid motor...
... OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Push up to be installed over a tub or shower, it can be connected to the receptacle). Before servicing or cleaning the unit, switch power off power unit. 3. Installation work and electrical wiring must not be done by the manufacturer. Unit must be installed in a wall. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. To avoid motor...
Owner's Manual
Page 3
Before Installation 1 Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes NOTE: Remove all the parts. If damaged, call 1-888-830-1326 for replacements. E 95044-01-000 F 95022-01-000 G 75190-01-000 H 03242-07-133 I 95492-04-000 x2 J 74508-03-133 K 77520-01 L ...65219 M 96373-01-214 N 75184-01-133 O 96374-01-214 Included. Check all packing materials before installation. 2 J F Turn off the power source. 3 41949-01 09/09/2011 Loosen screws. Not Included. x5 A *B *C 3/8" Cable Connector x2 D Extra Screws * NOTE: Strain relief cable...
Before Installation 1 Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes NOTE: Remove all the parts. If damaged, call 1-888-830-1326 for replacements. E 95044-01-000 F 95022-01-000 G 75190-01-000 H 03242-07-133 I 95492-04-000 x2 J 74508-03-133 K 77520-01 L ...65219 M 96373-01-214 N 75184-01-133 O 96374-01-214 Included. Check all packing materials before installation. 2 J F Turn off the power source. 3 41949-01 09/09/2011 Loosen screws. Not Included. x5 A *B *C 3/8" Cable Connector x2 D Extra Screws * NOTE: Strain relief cable...
Owner's Manual
Page 4
3 4 I F Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 H Back out the pre-loaded screw tips until flush with the side of the housing. 8 G Remove the wiring cover screw. 4 41949-01 09/09/2011 Remove the wiring cover.
3 4 I F Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 H Back out the pre-loaded screw tips until flush with the side of the housing. 8 G Remove the wiring cover screw. 4 41949-01 09/09/2011 Remove the wiring cover.
Owner's Manual
Page 5
...Screw pre-loaded screws into the housing and secure with washer. suspended between joists go to step C11, page 11 For Existing Construction - attaching to joist go to joist A11 F A12 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Choose Installation Option For New... Construction - 9 10 F C Pop out the first wiring access slug. Use second if needed.
...Screw pre-loaded screws into the housing and secure with washer. suspended between joists go to step C11, page 11 For Existing Construction - attaching to joist go to joist A11 F A12 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Choose Installation Option For New... Construction - 9 10 F C Pop out the first wiring access slug. Use second if needed.
Owner's Manual
Page 6
... fit securely, an adapter may need to the outside. A14 Fan Motor Night Light Light Black 2 Pin White White Red Night Light 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Red Switch 1 (AC In) Black Switch 2 (AC In) Connect wires as shown. For supply connection, use wires suitable for at least 90º C (194º F). A15 A016 F H Install the wiring cover plate. Make sure all wiring connections are inside the box...
... fit securely, an adapter may need to the outside. A14 Fan Motor Night Light Light Black 2 Pin White White Red Night Light 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Red Switch 1 (AC In) Black Switch 2 (AC In) Connect wires as shown. For supply connection, use wires suitable for at least 90º C (194º F). A15 A016 F H Install the wiring cover plate. Make sure all wiring connections are inside the box...
Owner's Manual
Page 7
A19 A20 J Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Test the motor. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. If the motor does not run, check the plug connection. 7 41949-01 09/09/2011 Turn on page 17 to attach grille. A21 ON A22 Go to step E1 OFF on the power source. A17 0 A18 0 Connect wiring harness. I Reinstall the motor by tightening the 2 screws.
A19 A20 J Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Test the motor. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. If the motor does not run, check the plug connection. 7 41949-01 09/09/2011 Turn on page 17 to attach grille. A21 ON A22 Go to step E1 OFF on the power source. A17 0 A18 0 Connect wiring harness. I Reinstall the motor by tightening the 2 screws.
Owner's Manual
Page 8
B13 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of each outline. B14 F Mark position of screws by using holes as a template. 1/8" bit Drill a hole in the center of your sheetrock. B15 B16 Insert screws, leaving space between joists B11 B12 F E Slide the mounting rails into brackets. Screws are not provided. 8 41949-01 09/09/2011 Attach the rails onto the screws. suspended between the screw head and the joist. New Construction -
B13 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of each outline. B14 F Mark position of screws by using holes as a template. 1/8" bit Drill a hole in the center of your sheetrock. B15 B16 Insert screws, leaving space between joists B11 B12 F E Slide the mounting rails into brackets. Screws are not provided. 8 41949-01 09/09/2011 Attach the rails onto the screws. suspended between the screw head and the joist. New Construction -
Owner's Manual
Page 9
... connection, use wires suitable for at least 90º C (194º F). Route wires through strain relief. B20 B21 G H Install the wiring cover plate. If ducting does not fit securely, an adapter may need to the outside. Make sure all wiring connections are inside the box or under the wiring cover plate. B19 Fan Motor Night Light Light Black 2 Pin White White Red Night Light 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch...
... connection, use wires suitable for at least 90º C (194º F). Route wires through strain relief. B20 B21 G H Install the wiring cover plate. If ducting does not fit securely, an adapter may need to the outside. Make sure all wiring connections are inside the box or under the wiring cover plate. B19 Fan Motor Night Light Light Black 2 Pin White White Red Night Light 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch...
Owner's Manual
Page 10
Test the motor. Make sure the wires are not pinched between the motor and the housing. B24 B25 J Secure the motor by inserting the tabs and pushing up into position. If the motor does not run, check the plug connection. 10 41949-01 09/09/2011 B26 ON B27 Go to step E1 OFF on the power source. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Reinstall the motor by tightening the 2 screws. Turn on page 17 to attach grille. B22 B23 I I Connect wiring harness.
Test the motor. Make sure the wires are not pinched between the motor and the housing. B24 B25 J Secure the motor by inserting the tabs and pushing up into position. If the motor does not run, check the plug connection. 10 41949-01 09/09/2011 B26 ON B27 Go to step E1 OFF on the power source. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Reinstall the motor by tightening the 2 screws. Turn on page 17 to attach grille. B22 B23 I I Connect wiring harness.
Owner's Manual
Page 11
C13 Slide the mounting rails into brackets. Existing Construction - accessible from above C11 EXISTING FAN NO EXISTING FAN OR Remove an existing fan and check to make sure the opening for the housing. C12 F E Cut out an opening is large enough to mark position. Mark position of your sheetrock. C14 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of screws by using holes as a template to accommodate the new motor housing (9"x 9.75"). 9" 9.75" Use the motor housing as a template. 11 41949-01 09/09/2011
C13 Slide the mounting rails into brackets. Existing Construction - accessible from above C11 EXISTING FAN NO EXISTING FAN OR Remove an existing fan and check to make sure the opening for the housing. C12 F E Cut out an opening is large enough to mark position. Mark position of your sheetrock. C14 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of screws by using holes as a template to accommodate the new motor housing (9"x 9.75"). 9" 9.75" Use the motor housing as a template. 11 41949-01 09/09/2011
Owner's Manual
Page 12
C19 Tighten screws. C18 Attach the rails onto the screws. C20 Connect 4" duct and vent to be purchased. Tape joints. For supply connection, use wires suitable for at least 90º C (194º F). 12 41949-01 09/09/2011 C15 C16 Drill a hole in the center of each outline. Route wires through strain relief. If ducting does not fit securely, an adapter may need to the outside. C17 Insert screws, leaving space between the screw head and the joist. Screws are not provided.
C19 Tighten screws. C18 Attach the rails onto the screws. C20 Connect 4" duct and vent to be purchased. Tape joints. For supply connection, use wires suitable for at least 90º C (194º F). 12 41949-01 09/09/2011 C15 C16 Drill a hole in the center of each outline. Route wires through strain relief. If ducting does not fit securely, an adapter may need to the outside. C17 Insert screws, leaving space between the screw head and the joist. Screws are not provided.
Owner's Manual
Page 13
C23 C24 G I H Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. 13 41949-01 09/09/2011 C22 Fan Motor Night Light Light Black 2 Pin White 3 Pin White Red Night Light Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Red Switch 1 (AC In) Black Switch 2 (AC In) Connect wires as shown. Connect wiring harness. C21 Tighten the strain relief screws.
C23 C24 G I H Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. 13 41949-01 09/09/2011 C22 Fan Motor Night Light Light Black 2 Pin White 3 Pin White Red Night Light Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Red Switch 1 (AC In) Black Switch 2 (AC In) Connect wires as shown. Connect wiring harness. C21 Tighten the strain relief screws.
Owner's Manual
Page 14
Test the motor. C27 C28 ON OFF Turn on page 17 to attach grille. If the motor does not run, check the plug connection. 14 41949-01 09/09/2011 C25 C26 I Reinstall the motor by tightening the 2 screws. C29 Go to step E1 on the power source. J Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
Test the motor. C27 C28 ON OFF Turn on page 17 to attach grille. If the motor does not run, check the plug connection. 14 41949-01 09/09/2011 C25 C26 I Reinstall the motor by tightening the 2 screws. C29 Go to step E1 on the power source. J Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
Owner's Manual
Page 15
... pre-loaded screws into position above the ceiling D13 D14 2 1 Route wires through strain relief. accessible only from below D11 EXISTING FAN D12 F Remove an existing fan and check to make sure the opening is large enough to be purchased. Tape joints. If ducting does not fit securely, an adapter may need to accommodate the new motor housing (9"x 9.75"). For supply connection, use wires suitable for...
... pre-loaded screws into position above the ceiling D13 D14 2 1 Route wires through strain relief. accessible only from below D11 EXISTING FAN D12 F Remove an existing fan and check to make sure the opening is large enough to be purchased. Tape joints. If ducting does not fit securely, an adapter may need to accommodate the new motor housing (9"x 9.75"). For supply connection, use wires suitable for...
Owner's Manual
Page 16
... the motor and the housing. 16 Secure the motor by inserting the tabs and pushing up into position. D16 Fan Motor Night Light Light 2 Pin Black White White Red Night Light 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Red Switch 1 (AC In) Black Switch 2 (AC In) Connect wires as shown. D17 D18 G H Install the wiring cover plate. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING...
... the motor and the housing. 16 Secure the motor by inserting the tabs and pushing up into position. D16 Fan Motor Night Light Light 2 Pin Black White White Red Night Light 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Red Switch 1 (AC In) Black Switch 2 (AC In) Connect wires as shown. D17 D18 G H Install the wiring cover plate. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING...
Owner's Manual
Page 17
D23 Go to step E1 on the power source. If the motor does not run, check the plug connection. D21 Turn on page 17 to attach grille. Attaching the Grille E1 E2 F N M Remove the thumbscrews. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. 17 41949-01 09/09/2011 D22 ON OFF Test the motor.
D23 Go to step E1 on the power source. If the motor does not run, check the plug connection. D21 Turn on page 17 to attach grille. Attaching the Grille E1 E2 F N M Remove the thumbscrews. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. 17 41949-01 09/09/2011 D22 ON OFF Test the motor.
Owner's Manual
Page 18
.... Turn glass dome assembly as shown, and screw into place. E6 N Attach thumbscrews. E3 E4 K M Position the strain relief bracket between the plugs as shown until it locks into position. 18 41949-01 09/09/2011 E5 Align posts A, B, C and D (stamped into motor housing) with slots on light fixture, and insert tabs into light fixture). E7 Install 2 Max 60 watt A-15 bulbs (Not...
.... Turn glass dome assembly as shown, and screw into place. E6 N Attach thumbscrews. E3 E4 K M Position the strain relief bracket between the plugs as shown until it locks into position. 18 41949-01 09/09/2011 E5 Align posts A, B, C and D (stamped into motor housing) with slots on light fixture, and insert tabs into light fixture). E7 Install 2 Max 60 watt A-15 bulbs (Not...
Owner's Manual
Page 19
...: • C heck and tighten all plug connections to be sure they are extremely quiet. Solution: • Hunter Fan Bath Ventilators are secure. • C heck the wiring to make sure it matches the wiring diagram. Problem: Light does not come on . Solution: • R eplace the light bulb with a new bulb. • T urn power on , replace fuse, or reset breaker. • Check all plug connections to be sure they are secure...
...: • C heck and tighten all plug connections to be sure they are extremely quiet. Solution: • Hunter Fan Bath Ventilators are secure. • C heck the wiring to make sure it matches the wiring diagram. Problem: Light does not come on . Solution: • R eplace the light bulb with a new bulb. • T urn power on , replace fuse, or reset breaker. • Check all plug connections to be sure they are secure...
Owner's Manual
Page 20
... SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within five years after the date of sale to you due to our factory or service center. If no replacement part...
... SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within five years after the date of sale to you due to our factory or service center. If no replacement part...