...2006 Honeywell International Inc. Registered Trademark. Owner's Manual English: Page 1 Mode d'emploi Français: Page 6 Manual de Uso Español: Página 11 T834 Series Thermostat This manual covers the following models: Horizontal Mount: T8034N • Vertical Mount: T834N/T834L... Pre-installation checklist Check package contents: • Thermostat • Wall anchors & screws (2 each) Before you begin, make ...
...2006 Honeywell International Inc. Registered Trademark. Owner's Manual English: Page 1 Mode d'emploi Français: Page 6 Manual de Uso Español: Página 11 T834 Series Thermostat This manual covers the following models: Horizontal Mount: T8034N • Vertical Mount: T834N/T834L... Pre-installation checklist Check package contents: • Thermostat • Wall anchors & screws (2 each) Before you begin, make ...
Owner's Manual
Page 2
T834 Series Product application This thermostat provides control of 24 Vac single-stage heating and cooling systems. System Types • Gas, oil, or electric heat with air conditioning • Warm air, ... water, high-efficiency furnaces, heat pumps, steam, gravity • Heat only • Heat only with fan • Cool only System Settings • Heat, Off, Cool (T834N) • Off, Cool (T834L) Fan Settings Specifications Temperature Range • 50° to 90°F (10° to 32°C) Operating Ambient Temperature • 0°...
T834 Series Product application This thermostat provides control of 24 Vac single-stage heating and cooling systems. System Types • Gas, oil, or electric heat with air conditioning • Warm air, ... water, high-efficiency furnaces, heat pumps, steam, gravity • Heat only • Heat only with fan • Cool only System Settings • Heat, Off, Cool (T834N) • Off, Cool (T834L) Fan Settings Specifications Temperature Range • 50° to 90°F (10° to 32°C) Operating Ambient Temperature • 0°...
Owner's Manual
Page 3
.... ** G Fan relay. Heat pump systems If wiring to connect terminals W and Y. Terminal Designations R Heating power. Wire specifications Use 18-gauge thermostat wire. Check level if desired. Connect to prevent drafts from affecting thermostat operation. Shielded cable is not required. 3 English: Page 1 • Français: Page 6 • Español: Página...
.... ** G Fan relay. Heat pump systems If wiring to connect terminals W and Y. Terminal Designations R Heating power. Wire specifications Use 18-gauge thermostat wire. Check level if desired. Connect to prevent drafts from affecting thermostat operation. Shielded cable is not required. 3 English: Page 1 • Français: Page 6 • Español: Página...
Owner's Manual
Page 4
...in a call for heat.) E: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.) Set heat anticipator (except model T834L) Move the... for your system (see table below). Tab 4 Your system Steam Hot water heat Warm air (high efficiency) Warm air (standard) Electric heat Setting 1.2 0.8 0.8 0.4 0.3 Thermostat mounting Align the slots on the cover with tabs on the sides of the base, then push gently until the cover snaps into place.
...in a call for heat.) E: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.) Set heat anticipator (except model T834L) Move the... for your system (see table below). Tab 4 Your system Steam Hot water heat Warm air (high efficiency) Warm air (standard) Electric heat Setting 1.2 0.8 0.8 0.4 0.3 Thermostat mounting Align the slots on the cover with tabs on the sides of the base, then push gently until the cover snaps into place.