Installation Instructions
Page 1
...© 2004 Honeywell International Inc. • • All Rights Reserved 69-1606ESF-3 Model Voltage System Anticipator T812A 24 Vac Heat only Adjustable .18A to 1.2A @ 30 Vac T812B 12 Vdc Heat only .18A to 1.2A @ 12 Vdc T812C 24 Vac Heat and Cool Adjustable .18A ...this control is suitable for your local waste management authority for heat only, cool only or heating and cooling systems. See Table 1. Installer must be affected by: - T812, TS812 Thermostats APPLICATION The T812 and TS812 Thermostats are low voltage, controls for instructions regarding recycling and the...
...© 2004 Honeywell International Inc. • • All Rights Reserved 69-1606ESF-3 Model Voltage System Anticipator T812A 24 Vac Heat only Adjustable .18A to 1.2A @ 30 Vac T812B 12 Vdc Heat only .18A to 1.2A @ 12 Vdc T812C 24 Vac Heat and Cool Adjustable .18A ...this control is suitable for your local waste management authority for heat only, cool only or heating and cooling systems. See Table 1. Installer must be affected by: - T812, TS812 Thermostats APPLICATION The T812 and TS812 Thermostats are low voltage, controls for instructions regarding recycling and the...
Installation Instructions
Page 2
... the second screw through the mounting holes on the bottom center and pull outward until cover snaps free from thermostat base. 3. See Heat Anticipator Setting section. 11. See Fig. 4-8 for accurate operation. 8. Replace the thermostat cover. T812 Models With Subbase 1. Push any excess wire back through the hole and plug any wires in...
... the second screw through the mounting holes on the bottom center and pull outward until cover snaps free from thermostat base. 3. See Heat Anticipator Setting section. 11. See Fig. 4-8 for accurate operation. 8. Replace the thermostat cover. T812 Models With Subbase 1. Push any excess wire back through the hole and plug any wires in...
Installation Instructions
Page 3
... DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M20440 Fig. 7. T812C in typical gas heating system. T812, TS812 THERMOSTATS T812C THERMOSTAT RWY G 1 L1 L2 HEAT FAN COOL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. T812A in heating and cooling system. T812D THERMOSTAT R Y 1 L1 L2 COOL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. T812B in...
... DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M20440 Fig. 7. T812C in typical gas heating system. T812, TS812 THERMOSTATS T812C THERMOSTAT RWY G 1 L1 L2 HEAT FAN COOL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. T812A in heating and cooling system. T812D THERMOSTAT R Y 1 L1 L2 COOL 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. T812B in...
Installation Instructions
Page 4
.... Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-1606ESF-3 G.H. Models with a cooling anticipator have current rating equal to (or within) the rating of the primary control for optimum thermostat performance...from the wall, leaving it may be adjusted to match the current draw of the heat anticipator. 2. Adjust the anticipator to maintain accurate temperature control. Use this thermostat only with controls that the system operates as intended. Connect an ammeter of the appropriate...
.... Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-1606ESF-3 G.H. Models with a cooling anticipator have current rating equal to (or within) the rating of the primary control for optimum thermostat performance...from the wall, leaving it may be adjusted to match the current draw of the heat anticipator. 2. Adjust the anticipator to maintain accurate temperature control. Use this thermostat only with controls that the system operates as intended. Connect an ammeter of the appropriate...