User Guide
Page 1
...,B,C Programmable Thermostats The T8131 and T8132 Thermostats provide energy savings for weekdays and weekends 5 day/2 day. s Digital LCD display. s Easy to program and install. s Green light emitting diode (LED) lights when prop- s AUTO-ON fan switch. s Separate programs for single-stage heating and cooling applications while providing reliable, precise temperature control. s LCD flashes "bAt Lo" indicating low battery power. s Four daily energy saving programs. s Available in taupe and Premier White™. T8131C T8132C T8131/T8132 Models s HEAT-OFF-COOL system switch...
...,B,C Programmable Thermostats The T8131 and T8132 Thermostats provide energy savings for weekdays and weekends 5 day/2 day. s Digital LCD display. s Easy to program and install. s Green light emitting diode (LED) lights when prop- s AUTO-ON fan switch. s Separate programs for single-stage heating and cooling applications while providing reliable, precise temperature control. s LCD flashes "bAt Lo" indicating low battery power. s Four daily energy saving programs. s Available in taupe and Premier White™. T8131C T8132C T8131/T8132 Models s HEAT-OFF-COOL system switch...
User Guide
Page 2
.... lights to comment on wall using two mounting screws and wall anchors provided (See Fig. 2). OPERATING AMBIENT TEMPERATURE RANGE: 40° F to 110° F [4° C to 31° C]. Accessories, if desired. Manufacturing in performance can be expected if those conditions are properly connected. with AM, PM indication. SYSTEM AND FAN RATINGS: 1.2A run; 7.5A inrush. Order Number. 2. MODELS: T8131A/T8132A Programmable Thermostats: Provide eight program keys; SET...
.... lights to comment on wall using two mounting screws and wall anchors provided (See Fig. 2). OPERATING AMBIENT TEMPERATURE RANGE: 40° F to 110° F [4° C to 31° C]. Accessories, if desired. Manufacturing in performance can be expected if those conditions are properly connected. with AM, PM indication. SYSTEM AND FAN RATINGS: 1.2A run; 7.5A inrush. Order Number. 2. MODELS: T8131A/T8132A Programmable Thermostats: Provide eight program keys; SET...
User Guide
Page 3
... service technician. 4. Level for zone valves. Cooling: Factory-set at average temperature. T8132A,B,C SPECIFICATIONS • INSTALLATION Fig. 2-T8131 LED. System Type Compatible with T8131/T8132 Gas-Standing Pilot Yes Gas-Electronic Ignition Yes Gas-Fired Boilers Yesa Gas-Millivolt No Oil-Fired Boilers Yesa Oil-Fired Furnace Yes Electric Furnace Yes Electric Air Conditioning Yes Baseboard Electric No (120/240 Line Volt) Heat pumps/Multistage Equipment No Not compatible with 2-wire Honeywell...
... service technician. 4. Level for zone valves. Cooling: Factory-set at average temperature. T8132A,B,C SPECIFICATIONS • INSTALLATION Fig. 2-T8131 LED. System Type Compatible with T8131/T8132 Gas-Standing Pilot Yes Gas-Electronic Ignition Yes Gas-Fired Boilers Yesa Gas-Millivolt No Oil-Fired Boilers Yesa Oil-Fired Furnace Yes Electric Furnace Yes Electric Air Conditioning Yes Baseboard Electric No (120/240 Line Volt) Heat pumps/Multistage Equipment No Not compatible with 2-wire Honeywell...
User Guide
Page 4
... typical wiring diagrams. T8132 Models Run the required number of wires to remove the factory-installed jumper connecting terminals R and Rc. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M9214 68-0148-1 4 Loosen the terminal screws and slip each wire beneath its matching terminal. Tighten terminals securely. M9212 Fig. 7-5-wire heat/cool application. 5-WIRE HEAT/COOL A B W Y G C R HEATING RELAY OR VALVE COIL FAN RELAY COOLING CONTACTOR COIL 1 L1 (HOT) L2 1 POWER SUPPLY. PROPER WIRING TECHNIQUE 5/16 in the wall with...
... typical wiring diagrams. T8132 Models Run the required number of wires to remove the factory-installed jumper connecting terminals R and Rc. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M9214 68-0148-1 4 Loosen the terminal screws and slip each wire beneath its matching terminal. Tighten terminals securely. M9212 Fig. 7-5-wire heat/cool application. 5-WIRE HEAT/COOL A B W Y G C R HEATING RELAY OR VALVE COIL FAN RELAY COOLING CONTACTOR COIL 1 L1 (HOT) L2 1 POWER SUPPLY. PROPER WIRING TECHNIQUE 5/16 in the wall with...
User Guide
Page 5
... AS REQUIRED. M1710B Fig. 11-5-wire heat/cool application (jumper removed). 5-WIRE HEAT/COOL (JUMPER REMOVED) A C B D W Y G R Rc HEATING RELAY OR VALVE COIL FAN RELAY 1 L1 (HOT) L2 COOLING CONTACTOR COIL 1 L1 (HOT) L2 1 POWER SUPPLY. T8132A,B,C INSTALLATION Fig. 10-4-wire heat/cool application (jumper intact). 4-WIRE HEAT/COOL (JUMPER INTACT) A C B D W Y G JUMPER R Rc HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY L1 (HOT) L2 1 POWER SUPPLY. M1711B 5 68-0148-1 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. PROVIDE...
... AS REQUIRED. M1710B Fig. 11-5-wire heat/cool application (jumper removed). 5-WIRE HEAT/COOL (JUMPER REMOVED) A C B D W Y G R Rc HEATING RELAY OR VALVE COIL FAN RELAY 1 L1 (HOT) L2 COOLING CONTACTOR COIL 1 L1 (HOT) L2 1 POWER SUPPLY. T8132A,B,C INSTALLATION Fig. 10-4-wire heat/cool application (jumper intact). 4-WIRE HEAT/COOL (JUMPER INTACT) A C B D W Y G JUMPER R Rc HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY L1 (HOT) L2 1 POWER SUPPLY. M1711B 5 68-0148-1 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. PROVIDE...
User Guide
Page 6
... blank display. Batteries are optional for steam/ gravity air. The thermostat will stay on -length is factory-set the switch to indicate the thermostat and heating/cooling system have a setting for T8131 models, but are completely dead, and the "bAt Lo" indicator will allow the fan to retain program memory if ac power is an electric heat system, set in a system where the "G" terminal is connected. T8131 THERMOSTAT BACK A B ADJUST SCREWS THROUGH HOLES TO SELECT OPERATION...
... blank display. Batteries are optional for steam/ gravity air. The thermostat will stay on -length is factory-set the switch to indicate the thermostat and heating/cooling system have a setting for T8131 models, but are completely dead, and the "bAt Lo" indicator will allow the fan to retain program memory if ac power is an electric heat system, set in a system where the "G" terminal is connected. T8131 THERMOSTAT BACK A B ADJUST SCREWS THROUGH HOLES TO SELECT OPERATION...
User Guide
Page 7
... plate (see Fig. 14) and then press the lower edge of battery power. A. PRESS LOWER EDGE OF CASE TO LATCH. IMPORTANT: Although the thermostat has a low battery indicator, replace the batteries once a year to prevent the thermostat from losing time and program due to lack of the case to latch. NOTE: FOR T8131A, C AND T8132A, C, SWING OPEN COVER. Fig. 13-Removing the battery door. B. CHECK OPERATION...
... plate (see Fig. 14) and then press the lower edge of battery power. A. PRESS LOWER EDGE OF CASE TO LATCH. IMPORTANT: Although the thermostat has a low battery indicator, replace the batteries once a year to prevent the thermostat from losing time and program due to lack of the case to latch. NOTE: FOR T8131A, C AND T8132A, C, SWING OPEN COVER. Fig. 13-Removing the battery door. B. CHECK OPERATION...
User Guide
Page 8
... COOL, follow the same instructions as applicable. To cancel sooner, press Run Program. then press Run Program. After programming, adjust fan and system switches as desired. T8132A,B,C PROGRAMMING THE THERMOSTAT Programming the Thermostat T8131A AND T8132A MODELS Set Current Time/Day To set day, press and release Clock/Day again, and then press Time v or w until the program to start the program. Heating Program With the system switch at HEAT, press and release Sched- To hold a temperature indefinitely, press Hold Temp, then Temp v or w. Press Time...
... COOL, follow the same instructions as applicable. To cancel sooner, press Run Program. then press Run Program. After programming, adjust fan and system switches as desired. T8132A,B,C PROGRAMMING THE THERMOSTAT Programming the Thermostat T8131A AND T8132A MODELS Set Current Time/Day To set day, press and release Clock/Day again, and then press Time v or w until the program to start the program. Heating Program With the system switch at HEAT, press and release Sched- To hold a temperature indefinitely, press Hold Temp, then Temp v or w. Press Time...
User Guide
Page 9
.... After programming, adjust fan and system switches as for "SLEEP." The temperature will cancel itself at HEAT, press and release Week- then press Run Program. T8131C AND T8132C MODELS Set Current Time/Day To set time, press and release Set Clock/Day once, then press Ahead or Back until the program to cancel shows; Heating Program With system switch at the next scheduled change. Cooling Program With system switch at COOL, follow the same instruc- To hold a temperature indefinitely, press Hold Temp then Warmer...
.... After programming, adjust fan and system switches as for "SLEEP." The temperature will cancel itself at HEAT, press and release Week- then press Run Program. T8131C AND T8132C MODELS Set Current Time/Day To set time, press and release Set Clock/Day once, then press Ahead or Back until the program to cancel shows; Heating Program With system switch at the next scheduled change. Cooling Program With system switch at COOL, follow the same instruc- To hold a temperature indefinitely, press Hold Temp then Warmer...
User Guide
Page 10
... the thermostat. Cooling For T8131 models only, before continuing check that the green power LED is lit, indicating the thermostat is changed, thermostat may delay up to five minutes before turning on the subbase, check operation as the gas valve, zone valve, or oil burner control. See compressor manufacturer instructions for further information. NOTE: When cooling setting is powered properly. The heating equipment should start and the fan should...
... the thermostat. Cooling For T8131 models only, before continuing check that the green power LED is lit, indicating the thermostat is changed, thermostat may delay up to five minutes before turning on the subbase, check operation as the gas valve, zone valve, or oil burner control. See compressor manufacturer instructions for further information. NOTE: When cooling setting is powered properly. The heating equipment should start and the fan should...
User Guide
Page 11
... and replace or reset if necessary. • If temperature setting is lit, move system switch from COOL to 31° C]. COOL: The thermostat controls the air conditioning system. Temperature display will not come on thermostat is lit. T8132 • If display is installed. Heating will turn on low with the air conditioner or furnace. A single-speed fan will not come on cooling. A two-speed fan will not come on . FAN ON: The fan runs continuously. Cool Off Heat IF... Cooling will usually run on...
... and replace or reset if necessary. • If temperature setting is lit, move system switch from COOL to 31° C]. COOL: The thermostat controls the air conditioning system. Temperature display will not come on thermostat is lit. T8132 • If display is installed. Heating will turn on low with the air conditioner or furnace. A single-speed fan will not come on cooling. A two-speed fan will not come on . FAN ON: The fan runs continuously. Cool Off Heat IF... Cooling will usually run on...
User Guide
Page 12
.... Honeywell Canada TRADELINE® model; T8132C1011 Replacement is coming from the registers. Fixed 6CPH. configurable for °F/°C. HH07AX016; C1003 Honeywell logo; C1011 Honeywell logo; Home and Building Control Honeywell Limited-Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 12 Helping You Control Your World QUALITY IS KEY SYSTEM ON indicator is lit, but no heat is Premier White™, °F only. Furnace or air conditioner cycles...
.... Honeywell Canada TRADELINE® model; T8132C1011 Replacement is coming from the registers. Fixed 6CPH. configurable for °F/°C. HH07AX016; C1003 Honeywell logo; C1011 Honeywell logo; Home and Building Control Honeywell Limited-Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 12 Helping You Control Your World QUALITY IS KEY SYSTEM ON indicator is lit, but no heat is Premier White™, °F only. Furnace or air conditioner cycles...