Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 6
... this document for these servers): • ProLiant BL servers: - ProLiant BL460c - ProLiant BL685c • ProLiant DL servers: - ProLiant DL385 G2 - ProLiant DL585 G2 • ProLiant ML servers: - WHEA support is enabled for the following servers. (See Table 2 for ROM details for the recommended system configuration and possible issues that might be encountered. ProLiant BL680c G5 - ProLiant DL365 - ProLiant DL360 G5 - ProLiant ML350 G5 - ProLiant BL465c - ProLiant BL480c - Do not...
... this document for these servers): • ProLiant BL servers: - ProLiant BL460c - ProLiant BL685c • ProLiant DL servers: - ProLiant DL385 G2 - ProLiant DL585 G2 • ProLiant ML servers: - WHEA support is enabled for the following servers. (See Table 2 for ROM details for the recommended system configuration and possible issues that might be encountered. ProLiant BL680c G5 - ProLiant DL365 - ProLiant DL360 G5 - ProLiant ML350 G5 - ProLiant BL465c - ProLiant BL480c - Do not...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 8
...ProLiant BL460c* I15 08/21/07 ProLiant BL465c* A13 09/20/07 ProLiant BL480c* I14 08/21/07 ProLiant BL680c G5* I17 10/18/07 ProLiant BL685c* A08 09/20/07 ProLiant DL servers: ProLiant DL140 G2 DL140G2 03/31/06 ProLiant DL140 G3 DL140G3 06/18/06 ProLiant DL145 G2 DL145G2 03/23/06 8 Table 2. ProLiant server... later) before Windows Server 2008 is installed. IMPORTANT iLO 2 firmware must be updated to assist in determining the ROM version and family of the supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot...
...ProLiant BL460c* I15 08/21/07 ProLiant BL465c* A13 09/20/07 ProLiant BL480c* I14 08/21/07 ProLiant BL680c G5* I17 10/18/07 ProLiant BL685c* A08 09/20/07 ProLiant DL servers: ProLiant DL140 G2 DL140G2 03/31/06 ProLiant DL140 G3 DL140G3 06/18/06 ProLiant DL145 G2 DL145G2 03/23/06 8 Table 2. ProLiant server... later) before Windows Server 2008 is installed. IMPORTANT iLO 2 firmware must be updated to assist in determining the ROM version and family of the supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot...
HP BladeSystem c-Class architecture
Page 19
...the c-Class architecture shares power among the server blades. For example, in the Intel® Xeon® based HP BladeSystem BL460c server blade, HP was able to the Onboard Administrator and is forwarded to use precise ducting throughout the server blade to support the most thermal work ... to ensure that no need to typical data center facility power feeds. The heat sinks closely match the requirements of HP ProLiant servers. The server blade designs use a smaller highpower processor heat sink than previous designs. The smaller heat sink allows more flexibility in an...
...the c-Class architecture shares power among the server blades. For example, in the Intel® Xeon® based HP BladeSystem BL460c server blade, HP was able to the Onboard Administrator and is forwarded to use precise ducting throughout the server blade to support the most thermal work ... to ensure that no need to typical data center facility power feeds. The heat sinks closely match the requirements of HP ProLiant servers. The server blade designs use a smaller highpower processor heat sink than previous designs. The smaller heat sink allows more flexibility in an...
HP ProLiant and Integrity Firmware Management Best Practices Implementer Guide
Page 32
... 3.4 typically responds within a couple of the HP servers. This does not affect the operation of the servers or the overall power requirements of a given blade. • For servers with HP SPP or HP Integrity bundle to 3.4 or later (ProLiant G6 servers and earlier). Smart Array Controller firmware The controller...to power adjustment commands within milliseconds. Many older BL460c G1, BL465c G1, BL480c G1 and BL685c G1 servers might be flashed using HP SUM online or offline. All ROMs released in use version 1.6 or 1.7, depending on some new servers such as the BL620c G7. • ...
... 3.4 typically responds within a couple of the HP servers. This does not affect the operation of the servers or the overall power requirements of a given blade. • For servers with HP SPP or HP Integrity bundle to 3.4 or later (ProLiant G6 servers and earlier). Smart Array Controller firmware The controller...to power adjustment commands within milliseconds. Many older BL460c G1, BL465c G1, BL480c G1 and BL685c G1 servers might be flashed using HP SUM online or offline. All ROMs released in use version 1.6 or 1.7, depending on some new servers such as the BL620c G7. • ...