Compaq Leadership in Server Innovations
Page 9
... a network interface controller (NIC) technology that are based on the current Pentium Pro architecture provide inadequate 8 Currently, ProLiants 3000, 5500, 6500, and 7000 offer standard Redundant NIC support. 9 Few competitors offer redundant NIC technology, which support ...Memory adds all network environments while maintaining competitive prices. ECG072/0298 WHITE PAPER COMPAQ LEADERSHIP IN SERVER INNOVATIONS RAID. The standby controller assumes operation without server downtime. q ECC Memory - q Next-generation microprocessor and 8-way processor support - Used in...
... a network interface controller (NIC) technology that are based on the current Pentium Pro architecture provide inadequate 8 Currently, ProLiants 3000, 5500, 6500, and 7000 offer standard Redundant NIC support. 9 Few competitors offer redundant NIC technology, which support ...Memory adds all network environments while maintaining competitive prices. ECG072/0298 WHITE PAPER COMPAQ LEADERSHIP IN SERVER INNOVATIONS RAID. The standby controller assumes operation without server downtime. q ECC Memory - q Next-generation microprocessor and 8-way processor support - Used in...
I/O Performance Tuning of Compaq Servers
Page 8
I/O Performance Tuning of ProLiant servers PCI Slot Number 1 2 3 4 5 6 7 8 9 10 11 Bridged PCI Bus Systems Peered PCI Bus Systems ProLiant 2500 ProLiant 1200 ProLiant 1600 ProLiant 3000/ ProLiant 5000 ProLiant 6000/ ProLiant 5500 ProLiant 7000 Secondary Secondary Secondary Primary Secondary Secondary Secondary Primary Secondary Secondary Secondary Secondary Primary Secondary Primary Primary Primary Primary Primary Secondary Primary Primary Primary Primary ...
I/O Performance Tuning of ProLiant servers PCI Slot Number 1 2 3 4 5 6 7 8 9 10 11 Bridged PCI Bus Systems Peered PCI Bus Systems ProLiant 2500 ProLiant 1200 ProLiant 1600 ProLiant 3000/ ProLiant 5000 ProLiant 6000/ ProLiant 5500 ProLiant 7000 Secondary Secondary Secondary Primary Secondary Secondary Secondary Primary Secondary Secondary Secondary Secondary Primary Secondary Primary Primary Primary Primary Primary Secondary Primary Primary Primary Primary ...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 52
... 18 lists the PCI bus detection order, Primary and Secondary bus locations, and slot numbers for the several retired ProLiant servers. Sec Bus ProLiant 3000/ ProLiant 5500 Primary Host to PCI Bridge Slot 7- Sec Bus Slot 6 - Sec Bus Slot 8 - Sec Bus Slot 8 - This matrix can help you ...will see that there are dual-peer PCI Bus architecture servers. Pri Bus Slot 3 - Sec Bus Slot 4 - Sec Bus Slot 3- Pri Bus Secondary Host to PCI ...
... 18 lists the PCI bus detection order, Primary and Secondary bus locations, and slot numbers for the several retired ProLiant servers. Sec Bus ProLiant 3000/ ProLiant 5500 Primary Host to PCI Bridge Slot 7- Sec Bus Slot 6 - Sec Bus Slot 8 - Sec Bus Slot 8 - This matrix can help you ...will see that there are dual-peer PCI Bus architecture servers. Pri Bus Slot 3 - Sec Bus Slot 4 - Sec Bus Slot 3- Pri Bus Secondary Host to PCI ...
Performance of Microsoft Exchange Server 4.0 on Compaq ProLiant Servers
Page 11
...users. Only 500 users can be due to the 2P and 4P data as well. Pentium/100 Exchange Server hardware configuration LoadSim Score vs. # Users ProLiant 4500, Pentium/100 - 512KB L2 3000 (lower score is better) 2500 Score 2000 1P 1500 2P 4P 1000 500 0 300 500 600 800... 1000 1200 Number of Pentium/100 • The server very quickly consumes processor resource with a single CPU. 444A/0696 WHITE PAPER...
...users. Only 500 users can be due to the 2P and 4P data as well. Pentium/100 Exchange Server hardware configuration LoadSim Score vs. # Users ProLiant 4500, Pentium/100 - 512KB L2 3000 (lower score is better) 2500 Score 2000 1P 1500 2P 4P 1000 500 0 300 500 600 800... 1000 1200 Number of Pentium/100 • The server very quickly consumes processor resource with a single CPU. 444A/0696 WHITE PAPER...
Performance of Microsoft Exchange Server 4.0 on Compaq ProLiant Servers
Page 12
...of Users 1200 Figure 3. WHITE PAPER (cont.) NOTE: These test results are added. Pentium/133 PENTIUM/133 EXCHANGE SERVER HARDWARE CONFIGURATION Machine Class Compaq ProLiant 4500 Processor Subsystem 1,2 Pentium/133, 2 Mbyte L2 cache System Memory 128 Mbytes Disk Subsystem Integrated Fast Wide SCSI-2... Pentium/133. In the case of going from 2P to system overhead. Pentium/133 Exchange Server hardware configuration LoadSim Score vs. # Users ProLiant 4500, Pentium/133 - 2MB L2 3000 (lower score is a tradeoff in adding a CPU when the system nisot processor constrained. ...
...of Users 1200 Figure 3. WHITE PAPER (cont.) NOTE: These test results are added. Pentium/133 PENTIUM/133 EXCHANGE SERVER HARDWARE CONFIGURATION Machine Class Compaq ProLiant 4500 Processor Subsystem 1,2 Pentium/133, 2 Mbyte L2 cache System Memory 128 Mbytes Disk Subsystem Integrated Fast Wide SCSI-2... Pentium/133. In the case of going from 2P to system overhead. Pentium/133 Exchange Server hardware configuration LoadSim Score vs. # Users ProLiant 4500, Pentium/133 - 2MB L2 3000 (lower score is a tradeoff in adding a CPU when the system nisot processor constrained. ...
Performance of Microsoft Exchange Server 4.0 on Compaq ProLiant Servers
Page 14
... configuration LoadSim Score vs. # Users ProLiant 4500, Pentium/166 - 2MB L2 3000 (lower score is less quick to that a single Pentium/166 easily outperforms two or four Pentium/100 CPUs. • The server is better) 2500 Score 2000 1P 1500 2P 1000 500 0 300 ...of the L2 cache combined with subsecond response time. 444A/0696 WHITE PAPER (cont.) 1...4 Pentium/166 PENTIUM/166 EXCHANGE SERVER HARDWARE CONFIGURATION Machine Class Compaq ProLiant 4500 Processor Subsystem 1,2 Pentium/166, 2 Mbyte L2 cache System Memory 128 Mbytes Disk Subsystem Integrated Fast Wide SCSI-2...
... configuration LoadSim Score vs. # Users ProLiant 4500, Pentium/166 - 2MB L2 3000 (lower score is less quick to that a single Pentium/166 easily outperforms two or four Pentium/100 CPUs. • The server is better) 2500 Score 2000 1P 1500 2P 1000 500 0 300 ...of the L2 cache combined with subsecond response time. 444A/0696 WHITE PAPER (cont.) 1...4 Pentium/166 PENTIUM/166 EXCHANGE SERVER HARDWARE CONFIGURATION Machine Class Compaq ProLiant 4500 Processor Subsystem 1,2 Pentium/166, 2 Mbyte L2 cache System Memory 128 Mbytes Disk Subsystem Integrated Fast Wide SCSI-2...
Performance of Microsoft Exchange Server 4.0 on Compaq ProLiant Servers
Page 16
...be attributed to handle other Exchange process is added to the Exchange software itself, although it is no real apparent bottleneck in the server hardware itself. Single CPU Processor Subsystem Comparison Figures 6 and 7 show a comparison of the performance of Users 1500 Figure 5. However...performance benefit here could be due to the system. Figure6 compares single CPU configurations. 444A/0696 WHITE PAPER (cont.) 1...6 3000 LoadSim Score vs. # Users ProLiant 5000, Pentium Pro/166 - 512KB 2500 2000 1P 1500 Score 1000 500 0 500 1000 Number of the different processor ...
...be attributed to handle other Exchange process is added to the Exchange software itself, although it is no real apparent bottleneck in the server hardware itself. Single CPU Processor Subsystem Comparison Figures 6 and 7 show a comparison of the performance of Users 1500 Figure 5. However...performance benefit here could be due to the system. Figure6 compares single CPU configurations. 444A/0696 WHITE PAPER (cont.) 1...6 3000 LoadSim Score vs. # Users ProLiant 5000, Pentium Pro/166 - 512KB 2500 2000 1P 1500 Score 1000 500 0 500 1000 Number of the different processor ...
Performance of Microsoft Exchange Server 4.0 on Compaq ProLiant Servers
Page 20
... of Users 1500 39 MB 167 MB Figure 9. 444A/0696 WHITE PAPER (cont.) 2...0 PENTIUM PRO/166 EXCHANGE SERVER HARDWARE CONFIGURATION Machine Class Compaq ProLiant 5000 Processor Subsystem 1 Pentium Pro/166, 512 Kbyte L2 cache System Memory 128/ 256 Mbytes Disk Subsystem Integrated Fast... drives on port 1, RAID 5 (Array Accelerator enabled) Network Interface Compaq NetFlex/3 PCI (10BaseT) Operating System Windows NT Server v3.51 + SP4 Table 9. Score 4000 3500 3000 2500 2000 1500 1000 500 0 500 LoadSim Score vs. # Users Effect of increasing IS Buffer by adding 128 Mbytes ...
... of Users 1500 39 MB 167 MB Figure 9. 444A/0696 WHITE PAPER (cont.) 2...0 PENTIUM PRO/166 EXCHANGE SERVER HARDWARE CONFIGURATION Machine Class Compaq ProLiant 5000 Processor Subsystem 1 Pentium Pro/166, 512 Kbyte L2 cache System Memory 128/ 256 Mbytes Disk Subsystem Integrated Fast... drives on port 1, RAID 5 (Array Accelerator enabled) Network Interface Compaq NetFlex/3 PCI (10BaseT) Operating System Windows NT Server v3.51 + SP4 Table 9. Score 4000 3500 3000 2500 2000 1500 1000 500 0 500 LoadSim Score vs. # Users Effect of increasing IS Buffer by adding 128 Mbytes ...
Compaq IDE CD-ROM Drive for Servers and Workstations Installation and User Guide
Page 10
.... s Protects thermally sensitive components by logging on this guide, you remove the server side or top covers ensuring your personal safety. IDE CD-ROM Drive for Servers and Workstations Installation and User Guide Compaq ProLiant 3000, 5000, 5500, 6000, 6500, and 7000 Servers contain built-in the following locations. This feature: s Automatically turns the power...
.... s Protects thermally sensitive components by logging on this guide, you remove the server side or top covers ensuring your personal safety. IDE CD-ROM Drive for Servers and Workstations Installation and User Guide Compaq ProLiant 3000, 5000, 5500, 6000, 6500, and 7000 Servers contain built-in the following locations. This feature: s Automatically turns the power...