HP P2000 G3 MSA System SMU Reference Guide
Page 36
...Introduction to manage the storage system, and disable the others. 2. Enable the options that enables interoperable management for HP Systems Insight Manager" at http://h18006.www1.hp.com/storage/pdfs/introsmis.pdf. • File Transfer Protocol (FTP). Set IP address source to run but cannot...in -band option is disabled, it continues to manual. 3. Used for increased security, or both . • Storage Management Initiative Spec. (SMIS). The specification was created by vendor. SMI-S enables management applications to the system. In-band management interfaces operate through the...
...Introduction to manage the storage system, and disable the others. 2. Enable the options that enables interoperable management for HP Systems Insight Manager" at http://h18006.www1.hp.com/storage/pdfs/introsmis.pdf. • File Transfer Protocol (FTP). Set IP address source to run but cannot...in -band option is disabled, it continues to manual. 3. Used for increased security, or both . • Storage Management Initiative Spec. (SMIS). The specification was created by vendor. SMI-S enables management applications to the system. In-band management interfaces operate through the...
HP P2000 G3 MSA System SMU Reference Guide
Page 126
... http://10.0.0.1 sysuptime timestamp of the last status change event, in a P2000 G3 MSA System. This MIB generally does not reference and integrate with the FibreAlliance MIB v2.2 Specification (FA MIB2.2 Spec). The revisions of the various components within the device includes such elements as ...for this MIB, go to or deleted from the connUnitTable) 126 SNMP reference It has been replaced by an ability to products with HP System Insight Manager (SIM) and other standard SNMP information; statusChangeTime is updated each time an event occurs. 0 at startup sysuptime ...
... http://10.0.0.1 sysuptime timestamp of the last status change event, in a P2000 G3 MSA System. This MIB generally does not reference and integrate with the FibreAlliance MIB v2.2 Specification (FA MIB2.2 Spec). The revisions of the various components within the device includes such elements as ...for this MIB, go to or deleted from the connUnitTable) 126 SNMP reference It has been replaced by an ability to products with HP System Insight Manager (SIM) and other standard SNMP information; statusChangeTime is updated each time an event occurs. 0 at startup sysuptime ...
HP P2000 G3 MSA System SMU Reference Guide
Page 127
...model name Model string Serial number for this connectivity unit is the principal unit within the group of fabric elements. HP P2000 G3 MSA System SMU Reference Guide 127 If this connectivity unit Default: Uninitialized Info Not supported invalid(2) for an... connUnitConfiguration ChangeTime connUnitNumRevs connUnitNumZones connUnitModuleId connUnitName connUnitInfo connUnitControl Includes the following objects as specified by 0xFFFF the FA MIB2.2 Spec Stand-alone unit returns yes for this object yes(3) since this is a stand-alone unit Whether this connectivity ...
...model name Model string Serial number for this connectivity unit is the principal unit within the group of fabric elements. HP P2000 G3 MSA System SMU Reference Guide 127 If this connectivity unit Default: Uninitialized Info Not supported invalid(2) for an... connUnitConfiguration ChangeTime connUnitNumRevs connUnitNumZones connUnitModuleId connUnitName connUnitInfo connUnitControl Includes the following objects as specified by 0xFFFF the FA MIB2.2 Spec Stand-alone unit returns yes for this object yes(3) since this is a stand-alone unit Whether this connectivity ...
HP P2000 G3 MSA System SMU Reference Guide
Page 128
...External details for the revision corresponds connUnitRevsTable on page 131 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of component being monitored See External details for by this sensor connUnitSensorTable on page 132 Characteristics being monitored by the ...128 SNMP reference Temperatures display in the connUnitEventTable Not supported 0 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this sensor table Unique value for each connUnitRevsEntry between 1 and...
...External details for the revision corresponds connUnitRevsTable on page 131 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of component being monitored See External details for by this sensor connUnitSensorTable on page 132 Characteristics being monitored by the ...128 SNMP reference Temperatures display in the connUnitEventTable Not supported 0 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this sensor table Unique value for each connUnitRevsEntry between 1 and...
HP P2000 G3 MSA System SMU Reference Guide
Page 129
... 133 Port number represented on the hardware Port number represented on the hardware Not supported 0 (No statistics available) HP P2000 G3 MSA System SMU Reference Guide 129 If this is not applicable, returns all bits set to 1 if the...connUnitPortSn connUnitPortRevision connUnitPortVendor connUnitPortSpeed connUnitPortControl connUnitPortName connUnitPortPhysical Number connUnitPortStatObject Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this port Unique value for each connUnitPortEntry between 1 ...
... 133 Port number represented on the hardware Port number represented on the hardware Not supported 0 (No statistics available) HP P2000 G3 MSA System SMU Reference Guide 129 If this is not applicable, returns all bits set to 1 if the...connUnitPortSn connUnitPortRevision connUnitPortVendor connUnitPortSpeed connUnitPortControl connUnitPortName connUnitPortPhysical Number connUnitPortStatObject Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this port Unique value for each connUnitPortEntry between 1 ...
HP P2000 G3 MSA System SMU Reference Guide
Page 130
... including relevant parameters or values Not supported N/A Not supported N/A Not supported N/A Not supported N/A The following objects per the FA MIB2.2 Spec IP address of the connectivity unit Same as connUnitId that contains this port Index into the connectivity unit's event buffer, incremented for each event... TRAPS trapMaxClients trapClientCount connUnitEventTrap trapRegTable trapRegIpAddress trapRegPort trapRegFilter Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of a client registered for this value. Default: warning(6) 130 SNMP reference
... including relevant parameters or values Not supported N/A Not supported N/A Not supported N/A Not supported N/A The following objects per the FA MIB2.2 Spec IP address of the connectivity unit Same as connUnitId that contains this port Index into the connectivity unit's event buffer, incremented for each event... TRAPS trapMaxClients trapClientCount connUnitEventTrap trapRegTable trapRegIpAddress trapRegPort trapRegFilter Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of a client registered for this value. Default: warning(6) 130 SNMP reference
HP P2000 G3 MSA Systems Installation Instructions
Page 2
...HP P2000 G3 MSA System Cable Configuration Guide. • These figures illustrate connecting a drive enclosure to Mini-SAS Consider the following environments are allowed in data throughput at nl http://www.hp.com/support/manuals. Step 3. Connect cables Simple, common cable configurations are included in any configuration is required. See the MSA Quick Specs... host port information for different P2000 G3 MSA controller models: Controller nl model Direct Switch Number of drive enclosures: HP drive enclosure HP P2000 HP D2700 HP MSA2000 HP MSA70 Description 6Gb 3.5" 12-drive...
...HP P2000 G3 MSA System Cable Configuration Guide. • These figures illustrate connecting a drive enclosure to Mini-SAS Consider the following environments are allowed in data throughput at nl http://www.hp.com/support/manuals. Step 3. Connect cables Simple, common cable configurations are included in any configuration is required. See the MSA Quick Specs... host port information for different P2000 G3 MSA controller models: Controller nl model Direct Switch Number of drive enclosures: HP drive enclosure HP P2000 HP D2700 HP MSA2000 HP MSA70 Description 6Gb 3.5" 12-drive...
HP StorageWorks P2000 G3 MSA System Cable Configuration Guide (590334-004, June 2010)
Page 2
.... • Mini-SAS to mini-SAS 0.5m (supplied) Figure 1 Full array configuration example . For more information, see the HP StorageWorks P2000 G3 MSA System Installation Instructions. Mixing 3Gbps drive enclosures with two servers accessing the storage. D2700 6Gb I/O ler module mini-SAS to...disk drive and expander link speed rate. NOTE: The figures in this document show only P2000 G3 FC controllers in performance limitations unless configured properly. See the MSA Quick Specs for details. • The maximum length cable allowed to connect enclosures in any configuration is...
.... • Mini-SAS to mini-SAS 0.5m (supplied) Figure 1 Full array configuration example . For more information, see the HP StorageWorks P2000 G3 MSA System Installation Instructions. Mixing 3Gbps drive enclosures with two servers accessing the storage. D2700 6Gb I/O ler module mini-SAS to...disk drive and expander link speed rate. NOTE: The figures in this document show only P2000 G3 FC controllers in performance limitations unless configured properly. See the MSA Quick Specs for details. • The maximum length cable allowed to connect enclosures in any configuration is...
HP StorageWorks P2000 G3 MSA System Installation Instructions (590335-004, June 2010)
Page 1
... Connect the P2000 G3 MSA System to servers Connect drive enclosures to change without notice. Depending on the Software Support/Documentation CD. 1. iSCSI ports (host or replication) 4. CLI port (mini-USB) 5. CLI port (mini-USB) 3. See the MSA Quick Specs for component ...servicing and installing computer equipment, and are included in this document is for future use 6. Management Ethernet port 5. HP StorageWorks P2000 G3 MSA System Installation Instructions © Copyright 2010 Hewlett-Packard Development Company, L.P. For the latest version of supported cable/...
... Connect the P2000 G3 MSA System to servers Connect drive enclosures to change without notice. Depending on the Software Support/Documentation CD. 1. iSCSI ports (host or replication) 4. CLI port (mini-USB) 5. CLI port (mini-USB) 3. See the MSA Quick Specs for component ...servicing and installing computer equipment, and are included in this document is for future use 6. Management Ethernet port 5. HP StorageWorks P2000 G3 MSA System Installation Instructions © Copyright 2010 Hewlett-Packard Development Company, L.P. For the latest version of supported cable/...