All NorthStar models
Page 5
... pump ... place pump and filter in the shade to ...Pump Location Locate pump...HP 3/4 1 1 1/2 2 2 1/2 3 FR "A" 13 1/4" 13 1/2" 14" 14 3/4" N/A 16 1/4" MR "A" N/A 13 1/4" 13 1/2" 14" 14 3/4" 16 1/4" FR: Full Rate MR: Max Rate Installation Instructions WARNING - NorthStar™ Pump... Series Product Specifications Page 5 of straight piping (shown as "L" in above diagram), equivalent to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). Pump Mounting Install pump on pipe or hose joints. Pump...Pump...
... pump ... place pump and filter in the shade to ...Pump Location Locate pump...HP 3/4 1 1 1/2 2 2 1/2 3 FR "A" 13 1/4" 13 1/2" 14" 14 3/4" N/A 16 1/4" MR "A" N/A 13 1/4" 13 1/2" 14" 14 3/4" 16 1/4" FR: Full Rate MR: Max Rate Installation Instructions WARNING - NorthStar™ Pump... Series Product Specifications Page 5 of straight piping (shown as "L" in above diagram), equivalent to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). Pump Mounting Install pump on pipe or hose joints. Pump...Pump...
All NorthStar models
Page 6
.... Voltage Voltage at the end of the fitting. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Avoid fittings that the wire size is running at least two ...pool, spa, or hot tub. Use a solid copper conductor, size 8 or larger. NorthStar™ Pump Series Pump Mounting (cont'd.) Page 6 of Plumbing and Mechanical Officials (IAPMO) standards. Fittings restrict flow....that could potentially cause electrical shock if grounded or shorted. Reference NEC codes for the HP (kW) rating and distance from external bonding lug to all applicable local codes, ...
.... Voltage Voltage at the end of the fitting. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Avoid fittings that the wire size is running at least two ...pool, spa, or hot tub. Use a solid copper conductor, size 8 or larger. NorthStar™ Pump Series Pump Mounting (cont'd.) Page 6 of Plumbing and Mechanical Officials (IAPMO) standards. Fittings restrict flow....that could potentially cause electrical shock if grounded or shorted. Reference NEC codes for the HP (kW) rating and distance from external bonding lug to all applicable local codes, ...
All NorthStar models
Page 7
...pump...HP KW 1 0.75 1-1/2 1.10 2 1.55 2-1/2 1.87 3 2.20 - - Remove any trapped air in the system by fully opening filter manual air relief valve until a steady stream of 15 Electrical (cont'd.) Wiring WARNING - NorthStar™ Pump... Series Page 7 of water (not air or air and water mix) is discharged from anywhere on the pump or filter, DO NOT start the pump...ensure pump ...Pump Fill strainer housing with starting the circulating pump system. Pump MUST be in severe personal injury. Run pressure test for this test. 2. WARNING - Full Rate (FR) HP...
...pump...HP KW 1 0.75 1-1/2 1.10 2 1.55 2-1/2 1.87 3 2.20 - - Remove any trapped air in the system by fully opening filter manual air relief valve until a steady stream of 15 Electrical (cont'd.) Wiring WARNING - NorthStar™ Pump... Series Page 7 of water (not air or air and water mix) is discharged from anywhere on the pump or filter, DO NOT start the pump...ensure pump ...Pump Fill strainer housing with starting the circulating pump system. Pump MUST be in severe personal injury. Run pressure test for this test. 2. WARNING - Full Rate (FR) HP...
All NorthStar models
Page 11
...(5 for 2-3 HP) WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS No. Part No. 1 SPX3200UNKIT 2 SPX3200UG 3 SPX4020TP 4 SPX4000M 5 SPX4000S 6 & 7 SPX4000CLO SPX4000CLOB 8 SPX4000T 9 SPX4000Z1 10 SPX4000B 11 SPX3021R 12 See SKU Detail Description Union Connector Kit (Includes Union Nut, Union Connector, Union Gasket - 2 ea.) Union Gasket Pump Strainer Housing, ... O-Ring Diffuser O-Ring Diffuser Impeller Ring Impeller Kit (Includes Impeller, Impeller Ring, Seal Assy) Ctn. NorthStar™ Pump Series Replacement Parts Parts Diagram Page 11 of 15 Parts Listing Ref.
...(5 for 2-3 HP) WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS No. Part No. 1 SPX3200UNKIT 2 SPX3200UG 3 SPX4020TP 4 SPX4000M 5 SPX4000S 6 & 7 SPX4000CLO SPX4000CLOB 8 SPX4000T 9 SPX4000Z1 10 SPX4000B 11 SPX3021R 12 See SKU Detail Description Union Connector Kit (Includes Union Nut, Union Connector, Union Gasket - 2 ea.) Union Gasket Pump Strainer Housing, ... O-Ring Diffuser O-Ring Diffuser Impeller Ring Impeller Kit (Includes Impeller, Impeller Ring, Seal Assy) Ctn. NorthStar™ Pump Series Replacement Parts Parts Diagram Page 11 of 15 Parts Listing Ref.
All NorthStar models
Page 12
NorthStar™ Pump Series Page 12 of 2) Ctn. Qty. 10 1 1 1 1 1 10 1 1 Pump SKU Detail Pump P/N SP4007 SP4010 SP4015 SP4020 SP4030 SP4007X10 SP4010X15 SP4015X20 SP4020X25 SP4025X30 SP4010X152 SP4015X202 SP4020X252 Description ¾ HP FR 1 HP FR 1 ½ HP FR 2 HP FR 3 HP FR 1 HP MR 1 ½ HP MR 2 HP MR 2 ½ HP MR 3 HP MR 1 ½ HP MR 2 SP 2 HP MR 2 SP 2 ½ HP MR 2 SP Note: FR: Full Rate...
NorthStar™ Pump Series Page 12 of 2) Ctn. Qty. 10 1 1 1 1 1 10 1 1 Pump SKU Detail Pump P/N SP4007 SP4010 SP4015 SP4020 SP4030 SP4007X10 SP4010X15 SP4015X20 SP4020X25 SP4025X30 SP4010X152 SP4015X202 SP4020X252 Description ¾ HP FR 1 HP FR 1 ½ HP FR 2 HP FR 3 HP FR 1 HP MR 1 ½ HP MR 2 HP MR 2 ½ HP MR 3 HP MR 1 ½ HP MR 2 SP 2 HP MR 2 SP 2 ½ HP MR 2 SP Note: FR: Full Rate...