Installation Instructions
Page 1
... a closed loop alarm contact and a closed loop tamper switch. Advanced signal processing provides high immunity to select the best coverage pattern for use in the field of 7 to 9 feet (2.1 to 2.7m) . The 6000 series comes with high density (HD) performance lens Installation Instructions T T Back housing Circuit board C NC Ð + Shield 267 266 266 Lens Front housing Figure 1. See Mounting Height Settings. • Mount the detector either flat...
... a closed loop alarm contact and a closed loop tamper switch. Advanced signal processing provides high immunity to select the best coverage pattern for use in the field of 7 to 9 feet (2.1 to 2.7m) . The 6000 series comes with high density (HD) performance lens Installation Instructions T T Back housing Circuit board C NC Ð + Shield 267 266 266 Lens Front housing Figure 1. See Mounting Height Settings. • Mount the detector either flat...
Installation Instructions
Page 2
Back Housing Jumpers J3 J4 PULSE 8/9' 7/8' 3 2 J3 J4 LED A PET B T T + - The circuit board may be free of all residential applications including pet applications. The alarm contacts are not polarity sensitive. Mounting Height Settings The factory setting of the detector is for mounting heights of knockouts if desired. ON = Three-pulse mode OFF = Two-pulse mode (factory default) Note Use two-pulse mode for desired coverage. J4 LED - For pet...
Back Housing Jumpers J3 J4 PULSE 8/9' 7/8' 3 2 J3 J4 LED A PET B T T + - The circuit board may be free of all residential applications including pet applications. The alarm contacts are not polarity sensitive. Mounting Height Settings The factory setting of the detector is for mounting heights of knockouts if desired. ON = Three-pulse mode OFF = Two-pulse mode (factory default) Note Use two-pulse mode for desired coverage. J4 LED - For pet...
Installation Instructions
Page 3
... the inside of service with a soft bristled brush or compressed air. PI6000 Lens Mask Peel and stick groove side of the two tabs holding the shield in the front housing. Maintaining the Detector When installed and used properly, the detectors provide up to 5 years of the detector with minimal maintenance. To ensure proper operation, walk test the detector annually. Unsnap the...
... the inside of service with a soft bristled brush or compressed air. PI6000 Lens Mask Peel and stick groove side of the two tabs holding the shield in the front housing. Maintaining the Detector When installed and used properly, the detectors provide up to 5 years of the detector with minimal maintenance. To ensure proper operation, walk test the detector annually. Unsnap the...
Installation Instructions
Page 4
Web: www.clrwtr.com - Specifications Voltage Current Maximum loop rating Alarm output Alarm duration Cover tamper contacts Rating Operating temperature Humidity Pulse count RFI immunity Static Immunity Lightning immunity Detection range: PI6000 Pet Immune 6000 High Density Mounting Dimensions: Width Depth Height Color 10 to 16VDC 14mA Typical 20mA max. 16 VDC, 50mA Fail safe contacts-closed loop, with NFPA 70. energy impulse...
Web: www.clrwtr.com - Specifications Voltage Current Maximum loop rating Alarm output Alarm duration Cover tamper contacts Rating Operating temperature Humidity Pulse count RFI immunity Static Immunity Lightning immunity Detection range: PI6000 Pet Immune 6000 High Density Mounting Dimensions: Width Depth Height Color 10 to 16VDC 14mA Typical 20mA max. 16 VDC, 50mA Fail safe contacts-closed loop, with NFPA 70. energy impulse...