Use and Care Manual
Page 1
....com. Room Air Conditioners GEAppliances.com Owner's Manual and Installation Instructions Safety Instructions 2, 3 Operating Instructions . . . . . .4-9 Care and Cleaning Air Filter 11 Front Grille 10 Grille and Case 10 Outdoor Coils 10 Installation Instructions Before You Begin 12, 13 Installing a J-Model in an Existing Wall Case 14 Through-the-Wall Installation 15 Window Installation (Optional 16-21 Troubleshooting Tips 22 Normal Operating Sounds 22 Consumer Support Consumer Support Back Cover Warranty 23 *ENERGY STAR® labeled product Cool Only: Heat/Cool: AJCM...
....com. Room Air Conditioners GEAppliances.com Owner's Manual and Installation Instructions Safety Instructions 2, 3 Operating Instructions . . . . . .4-9 Care and Cleaning Air Filter 11 Front Grille 10 Grille and Case 10 Outdoor Coils 10 Installation Instructions Before You Begin 12, 13 Installing a J-Model in an Existing Wall Case 14 Through-the-Wall Installation 15 Window Installation (Optional 16-21 Troubleshooting Tips 22 Normal Operating Sounds 22 Consumer Support Consumer Support Back Cover Warranty 23 *ENERGY STAR® labeled product Cool Only: Heat/Cool: AJCM...
Use and Care Manual
Page 2
... and also prevents overloading house wiring circuits which has a voltage rating that any servicing be replaced with a new power supply cord obtained from the power cord. Always grip plug firmly and pull straight out from overheated wires. ■ See the Installation Instructions, Electrical Requirements section for its length or at either the plug or connector end. ■ Turn OFF and unplug your air conditioner by pulling on a periodic basis...
... and also prevents overloading house wiring circuits which has a voltage rating that any servicing be replaced with a new power supply cord obtained from the power cord. Always grip plug firmly and pull straight out from overheated wires. ■ See the Installation Instructions, Electrical Requirements section for its length or at either the plug or connector end. ■ Turn OFF and unplug your air conditioner by pulling on a periodic basis...
Use and Care Manual
Page 3
... THIS SAFETY INFORMATION CAREFULLY. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com USE OF EXTENSION CORDS-115-Volt models only WARNING! If this is not done, the adapter ground terminal is very likely to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is properly grounded. You...
... THIS SAFETY INFORMATION CAREFULLY. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com USE OF EXTENSION CORDS-115-Volt models only WARNING! If this is not done, the adapter ground terminal is very likely to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is properly grounded. You...
Use and Care Manual
Page 4
.... Remote Control To cancel the On Timer, press the ON pad until the display time disappears. Air Conditioner Controls Lights beside the touch pads on the air conditioner controls will automatically increase 2°F after the second hour then 1°F each hour over the next two hours. Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions About the controls on in half an hour to set COOL or FAN mode at...
.... Remote Control To cancel the On Timer, press the ON pad until the display time disappears. Air Conditioner Controls Lights beside the touch pads on the air conditioner controls will automatically increase 2°F after the second hour then 1°F each hour over the next two hours. Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions About the controls on in half an hour to set COOL or FAN mode at...
Use and Care Manual
Page 5
... the COOL mode and HIGH fan with a lower set level of comfort. Press the INCREASE + / DECREASE - FAN MODE Use the FAN mode to 85°F in 1°F increments. Set the thermostat at the set temperature. Control Panel Press the MODE pad until the COOL indicator light is lit and the LOW, MED or HIGH indicator light is lit for the desired fan speed. 5 Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com COOL MODE Remote Control 1.
... the COOL mode and HIGH fan with a lower set level of comfort. Press the INCREASE + / DECREASE - FAN MODE Use the FAN mode to 85°F in 1°F increments. Set the thermostat at the set temperature. Control Panel Press the MODE pad until the COOL indicator light is lit and the LOW, MED or HIGH indicator light is lit for the desired fan speed. 5 Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com COOL MODE Remote Control 1.
Use and Care Manual
Page 6
... in COOL or HEAT mode. MODE On the air conditioner controls, use to 24. To cancel the Off Timer, press the OFF pad until the display time disappears. Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions About the controls on the air conditioner control panel indicate the selected settings. Air Conditioner Controls Lights beside the touch pads on the air conditioner-Heat/Cool Models Appearance may vary. Pads Use to 21 feet. Indicator lights will show the speed selected. Remote Control Signal...
... in COOL or HEAT mode. MODE On the air conditioner controls, use to 24. To cancel the Off Timer, press the OFF pad until the display time disappears. Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions About the controls on the air conditioner control panel indicate the selected settings. Air Conditioner Controls Lights beside the touch pads on the air conditioner-Heat/Cool Models Appearance may vary. Pads Use to 21 feet. Indicator lights will show the speed selected. Remote Control Signal...
Use and Care Manual
Page 7
...°F to begin . Since fan only settings do not provide cooling or heating, a temperature setting will take approximately 3 minutes for desired fan speed. 3. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com COOL MODE Remote Control 1. Control Panel Press the MODE pad until HIGH or LOW indicator light is lit for desired fan speed. 3. Press the FAN pad until HIGH or LOW indicator light is then turned on and off and...
...°F to begin . Since fan only settings do not provide cooling or heating, a temperature setting will take approximately 3 minutes for desired fan speed. 3. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com COOL MODE Remote Control 1. Control Panel Press the MODE pad until HIGH or LOW indicator light is lit for desired fan speed. 3. Press the FAN pad until HIGH or LOW indicator light is then turned on and off and...
Use and Care Manual
Page 8
... hole in the desired position. Fan Cycle/Continuous - The unit leaves the factory set at front. When this switch is down (continuous). Fan Cycle/Continuous - Fan Cycle/Continuous - Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions About the controls on the air conditioner Vent Control The vent control is disabled (DOWN), it allows the indoor fan to cycle on/off with a Class 2 Remote Control Wall Thermostat. When OPEN, the vent allows outdoor fresh air exchange. Remove the front grille...
... hole in the desired position. Fan Cycle/Continuous - The unit leaves the factory set at front. When this switch is down (continuous). Fan Cycle/Continuous - Fan Cycle/Continuous - Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions About the controls on the air conditioner Vent Control The vent control is disabled (DOWN), it allows the indoor fan to cycle on/off with a Class 2 Remote Control Wall Thermostat. When OPEN, the vent allows outdoor fresh air exchange. Remove the front grille...
Use and Care Manual
Page 9
... to any circuit. See the Front Grille section of the terminals and tighten screws securely. 4 After all connections and setting the appropriate dip switches. Special care must be controlled by a remote thermostat. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com Terminal Connections Remote Thermostat - Set aside screws and plastic cover. 3 To make wiring connections, insert the wires into the bottom of Care and Cleaning. 2 Remove the...
... to any circuit. See the Front Grille section of the terminals and tighten screws securely. 4 After all connections and setting the appropriate dip switches. Special care must be controlled by a remote thermostat. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com Terminal Connections Remote Thermostat - Set aside screws and plastic cover. 3 To make wiring connections, insert the wires into the bottom of Care and Cleaning. 2 Remove the...
Use and Care Manual
Page 10
... Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions Care and cleaning of the case. Front Grille The front grille can be checked regularly. Remove the two grille screws. 3. Grille and Case Turn the air conditioner off and remove the plug from the tabs on the front of the base pan. Do not use water and a mild detergent. If they may be professionally steam cleaned, a service available through your GE service outlet. Replace...
... Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions Care and cleaning of the case. Front Grille The front grille can be checked regularly. Remove the two grille screws. 3. Grille and Case Turn the air conditioner off and remove the plug from the tabs on the front of the base pan. Do not use water and a mild detergent. If they may be professionally steam cleaned, a service available through your GE service outlet. Replace...
Use and Care Manual
Page 11
... water through the filters. ■ Dry thoroughly before cleaning. A clogged filter reduces cooling, heating and air flow. To remove the air filter, on other models: FRONT FRONT Pull it back into position. Operating without the filter in place or with a damaged filter will : ■ Decrease cost of operation. ■ Save energy. ■ Prevent clogged heat exchanger coils. ■ Reduce the risk of premature component failure. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips...
... water through the filters. ■ Dry thoroughly before cleaning. A clogged filter reduces cooling, heating and air flow. To remove the air filter, on other models: FRONT FRONT Pull it back into position. Operating without the filter in place or with a damaged filter will : ■ Decrease cost of operation. ■ Save energy. ■ Prevent clogged heat exchanger coils. ■ Reduce the risk of premature component failure. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips...
Use and Care Manual
Page 12
... type of outdoor grille is not covered under the terms of the building. Observe all governing codes and ordinances. • Note to the GE air conditioner. IMPORTANT! J-MODEL QUALIFYING QUESTIONS J-model air conditioners may present special problems-consult a qualified electrician. Frequently, the J-model adapter kit will you be replacing? Approximately 1 hour • We recommend that two people install this air conditioner. This appliance must be installed on their own single branch circuit...
... type of outdoor grille is not covered under the terms of the building. Observe all governing codes and ordinances. • Note to the GE air conditioner. IMPORTANT! J-MODEL QUALIFYING QUESTIONS J-model air conditioners may present special problems-consult a qualified electrician. Frequently, the J-model adapter kit will you be replacing? Approximately 1 hour • We recommend that two people install this air conditioner. This appliance must be installed on their own single branch circuit...
Use and Care Manual
Page 13
... Westinghouse Wall Case (Type 2626D73H01) RAB46, 47 & 48 Use these instructions completely and carefully. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use this kit to a "J" model chassis. Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄4″D. Standard wall case for window installation. If you attach a custom architectural outdoor grille, use of the air conditioner and contact a qualified service...
... Westinghouse Wall Case (Type 2626D73H01) RAB46, 47 & 48 Use these instructions completely and carefully. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use this kit to a "J" model chassis. Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄4″D. Standard wall case for window installation. If you attach a custom architectural outdoor grille, use of the air conditioner and contact a qualified service...
Use and Care Manual
Page 14
... pan Power cord Clamp 2 REMOVE ALL SHIPPING PADS (IF PRESENT) INSIDE AIR CONDITIONER NEXT TO COMPRESSOR 6 ATTACH FRONT GRILLE An opening for the power cord is on the unit does not touch the wall case and that the case installation is secure. 14 Remove shipping pads (if present) 3 CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on the bottom of the front grille. Installation Instructions INSTALLING A J-MODEL IN...
... pan Power cord Clamp 2 REMOVE ALL SHIPPING PADS (IF PRESENT) INSIDE AIR CONDITIONER NEXT TO COMPRESSOR 6 ATTACH FRONT GRILLE An opening for the power cord is on the unit does not touch the wall case and that the case installation is secure. 14 Remove shipping pads (if present) 3 CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on the bottom of the front grille. Installation Instructions INSTALLING A J-MODEL IN...
Use and Care Manual
Page 15
.... Installation Instructions INSTALLING THROUGH THE WALL Read these instructions completely and carefully. 1 PREPARE OPENING IN WALL Make certain a wall receptacle is available close to the hole location or make arrangements to the left . 2 SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner wall case may be undercut at about 45° for the 115-volt models is 72″ to the right and 47″ to install a receptacle. The cord...
.... Installation Instructions INSTALLING THROUGH THE WALL Read these instructions completely and carefully. 1 PREPARE OPENING IN WALL Make certain a wall receptacle is available close to the hole location or make arrangements to the left . 2 SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner wall case may be undercut at about 45° for the 115-volt models is 72″ to the right and 47″ to install a receptacle. The cord...
Use and Care Manual
Page 16
... the accordion panels if needed to 43″ (With filler panels) 261⁄4″ min. (Without filler panels) Window opening dimensions to the right. • All supporting parts must be within reach of injury. Installation must be secured to firm wood, masonry or metal. • The electrical outlet must comply with these instructions completely and carefully. Risk of the power cord. 16 Air conditioner Type E (4) Support bracket hardware Spacer...
... the accordion panels if needed to 43″ (With filler panels) 261⁄4″ min. (Without filler panels) Window opening dimensions to the right. • All supporting parts must be within reach of injury. Installation must be secured to firm wood, masonry or metal. • The electrical outlet must comply with these instructions completely and carefully. Risk of the power cord. 16 Air conditioner Type E (4) Support bracket hardware Spacer...
Use and Care Manual
Page 22
... the house fuse/circuit breaker box and replace the fuse or reset the breaker. • If power failure occurs, turn the air conditioner OFF. The batteries may not be set the thermostat to a higher temperature to allow time for the room to cool down. • Check for open furnace registers and cold air returns. • Make sure the air conditioner's vent is normal. • For proper water disposal, make sure the air conditioner slants slightly...
... the house fuse/circuit breaker box and replace the fuse or reset the breaker. • If power failure occurs, turn the air conditioner OFF. The batteries may not be set the thermostat to a higher temperature to allow time for the room to cool down. • Check for open furnace registers and cold air returns. • Make sure the air conditioner's vent is normal. • For proper water disposal, make sure the air conditioner slants slightly...
Use and Care Manual
Page 23
... model number available when calling for home use including failure to provide reasonable and necessary maintenance. ■ In commercial locations labor necessary to move the unit to a location where it is product repair as provided in an area where service by possible defects with this Limited Warranty. For The Period Of: GE Will Replace: One Year From the date of the original purchase Any part of circuit breakers...
... model number available when calling for home use including failure to provide reasonable and necessary maintenance. ■ In commercial locations labor necessary to move the unit to a location where it is product repair as provided in an area where service by possible defects with this Limited Warranty. For The Period Of: GE Will Replace: One Year From the date of the original purchase Any part of circuit breakers...
Quick Specs
Page 1
... area are calculated by Underwriters Laboratories 390259 Specification Created 9/09 Listed by the Association of Home Appliance Manufacturers' standards. AJCM10ACD GE® ENERGY STAR® 115 Volt Built-in Room Air Conditioner Wall Case Dimensions and Installation Information (in inches) Note: When installing slide-out chassis units in through -the-wall applications, keep louvers free. Premium, Deluxe and Value Model Wall Case Dimensions (in inches) 15-5/8 For answers to...
... area are calculated by Underwriters Laboratories 390259 Specification Created 9/09 Listed by the Association of Home Appliance Manufacturers' standards. AJCM10ACD GE® ENERGY STAR® 115 Volt Built-in Room Air Conditioner Wall Case Dimensions and Installation Information (in inches) Note: When installing slide-out chassis units in through -the-wall applications, keep louvers free. Premium, Deluxe and Value Model Wall Case Dimensions (in inches) 15-5/8 For answers to...
Quick Specs
Page 3
Soft Gray AJCM12DCD Specification Created 9/09 390259 AJCM10ACD GE® ENERGY STAR® 115 Volt Built-in Room Air Conditioner Features and Benefits • R-410A Refrigerant • 10,400 Cooling BTU • 9.4 EER • 115 Volts • Energy Star® qualified • Electronic controls with remote • Electronic digital thermostat • Four-way air direction • Up-front, washable air filter • 3 cool/3 fan speeds • Unit dimensions: 14-7/8"H x 24-3/4"W x 19-7/8"D • Model AJCM10ACD -
Soft Gray AJCM12DCD Specification Created 9/09 390259 AJCM10ACD GE® ENERGY STAR® 115 Volt Built-in Room Air Conditioner Features and Benefits • R-410A Refrigerant • 10,400 Cooling BTU • 9.4 EER • 115 Volts • Energy Star® qualified • Electronic controls with remote • Electronic digital thermostat • Four-way air direction • Up-front, washable air filter • 3 cool/3 fan speeds • Unit dimensions: 14-7/8"H x 24-3/4"W x 19-7/8"D • Model AJCM10ACD -