Fujitsu MAU3147NC - Enterprise 147 GB Hard Drive Support and Manuals

Get Help and Manuals for this Fujitsu item

View All Support Options Below
Free Fujitsu MAU3147NC manuals!
Problems with Fujitsu MAU3147NC?

Ask a Question

Popular Fujitsu MAU3147NC Manual Pages

Product Manual - Page 7

... setting of terminals not described 5-5 in each sector where the maximum number of errors (up to the product or other property may not be corrected. [Total maximum byte: 9 byte × 3 ( interleave) = 27 byte] If the error of read sector keeps allowable error byte number, correction is performed in this manual are as follows: Task Mounting Installation...
Product Manual - Page 28

... Ultra 2 Wide LVD U160 U320 Areal density Data transfer rate (*10) Disk drive SCSI (Synchronous mode) Logical data block length SCSI command specification Data buffer Acoustic noise (Ready) Specification MAU3147NC/NP MAU3073NC/NP MAU3036NC/NP 147.0 GB (*2) 73.5 GB (*2) 36.7 GB (*2) 4 2 1 8 4 2 15,000 ± 0.2% 2.0 msec 0.2 ms/0.4 ms 3.3 ms/3.8 ms 8.0 ms/9.0 ms 30 s typ...
Product Manual - Page 29

... 512 bytes per sector. (*2) 1GB=1,000,000,000 bytes (*3) The seek time is as follows: Seek time [ms] Seek Difference [4096 Cyl/div] (*4) The start time is the time from power off or stop command. (*5) This value indicates at nominal voltage ± 1%. 25°C ambient. (*6) Up to 4 SCSI devices having capacitance of 25pF or less can use cable...
Product Manual - Page 30

... (about 80 IOPS) Ready +5 VDC Random ±5% (*6) W/R (about 80 IOPS) Ripple (*7) MAU3147NC/NP Specification MAU3073NC/NP 5 to 55°C -40 to 70°C -40 to 70°C MAU3036NC/NP 5 to 60°C 15°C/h or less 5 to 95%RH 5 to 95%RH 5... hole on the frame as much as possible. (*3) At random seek write/read and default on retry setting with log sweep vibration. 2-4 C141-E205
Product Manual - Page 32

... the system cabinet so that requires repair, adjustments, or replacement. Even if the IDD is used intermittently, the longest service life is the average time taken by a well-trained service mechanic to diagnose and repair a drive malfunction. Mishandling by the operator, failures due to bad environmental conditions, power trouble, host system trouble, cable failures, or other failures...
Product Manual - Page 49

...the data block. C141-E205 3-15 the sectors which can recover the twice error by the WRITE LONG command is rewritten and verified in automatic alternate block allocation...protection is prohibited through the setting terminal, the auto alternate block allocation processing specification is also applied for the second one command: ARRE = Twice AWRE (Type 1) = Eight times AWRE (Type 2) = ...
Product Manual - Page 57

... must allow access to the IDD for mounting screw Figure 4.7 Service clearance area (6) External magnetic field The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of the IDD is shown in Figure 4.7. [Surface P'] • Setting terminal (MP model only) • External operator panel connector [Surface P] • Cable...
Product Manual - Page 73

..., connections, setting switches and plugs, mounting drives, connecting cables, confirming drive operations after installation and preparation for use, and dismounting drives. 5.1 Notes on the PCAs except setting terminal (CN1...Do not touch any components on Handling Drives The items listed in the specifications in a dirty or contaminated environment. CAUTION Hot temperature To prevent injury...
Product Manual - Page 77

... must not change the setting of terminals except following terminals and SCSI terminating resistor before installing the IDD in the system as required. • Setting terminal: CN1 (NC model), CN2 (NP model) Figure 5.2 shows the location of the setting terminal for NP model, and Figure 5.3 shows the allocation and the default settings for NC model because the setting terminal is included in...
Product Manual - Page 80

... information on *1. The delay time is provided immediately after the power supply is Open Short (*2) turned on the SCSI ID. Table 5.2 Setting SCSI terminator power supply (NP model) Supply on/off of SCSI terminator power from IDD Supply off Supply on NP model, refer to Subsection 3.1.10 "START/STOP UNIT (1B)" in the SCSI Logical Interface Specifications for controlling the supply...
Product Manual - Page 81

... a short-circuit between CN2-13 and CN2-14 on NP model, the bus width for the SCSI interface is forcibly set to the external part of the SCSI interface (NP model) Bus width 16-bit bus 8-bit bus *1. Table 5.5 Setting of the bus width setting for the SCSI interface is not supported. Set at factory shipment. Pin pair 13/14 of CN2 (GND...
Product Manual - Page 89

...the number in the SCSI Logical Interface Specifications for each model (part number) when shipped from...error. Block descriptor Specify the size (byte length) of logical data blocks in the "data block length" field. The parameters are connected correctly. • The terminating resistor is installed in the format parameter (page code = 3) and drive parameter (page code... the setting of ...
Product Manual - Page 93

... operation status under the average system load requirements. It is recommended to use the default setting in normal operations. (2) Disconnection/reconnection parameters (page code = 2) The following parameters are used to optimize the start timing of the SCSI Logical Interface Specifications for how to the system requirements: • ARRE • AWRE • TB • PER 2. The...
Product Manual - Page 103

...not assume responsibility if data is destroyed during servicing or repair. Generally, the following information must be replaced in the field. Contact Fujitsu representative to submit information for the disk drive. C141-E205 6-7 The DE cannot be included: a) IDD model, part number (P/N), revision number, serial number (S/N), and date of manufacturing b) Error status • Date when the...
Product Manual - Page 110

... and +12 VDC is unstable, replace the power supply unit. For NP model, check the voltage between pin 36 and 76 of the SCSI connector. Make sure the maximum ripple peak-to 5.25 VDC. Check that the jumpers on the PCA are connected correctly. Table 6.2 System-level field troubleshooting Item DC power cable DC power...

Fujitsu MAU3147NC Reviews

Do you have an experience with the Fujitsu MAU3147NC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fujitsu yet.

Popular Fujitsu MAU3147NC Search Terms

The following terms are frequently used to search for Fujitsu MAU3147NC support:

Ask a New Question
Use the box below to post a new question about Fujitsu MAU3147NC.
Manuals / Documents
Download any of our Fujitsu MAU3147NC manuals for free!

We have the following 1 documents available for the Fujitsu MAU3147NC:
  • Product Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fujitsu Manuals

Find free Fujitsu MAU3147NC - Enterprise 147 GB Hard Drive manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fujitsu Reviews

View thousands of Fujitsu MAU3147NC - Enterprise 147 GB Hard Drive user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fujitsu customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fujitsu customer service rankings, employee comments and much more from our sister site.

Fujitsu Recalls

Find comprehensive Fujitsu recall information updated hourly on RecallOwl.com.