Installation Instructions (All Languages)
Page 1
All about the Installation of your Dryer TABLE OF CONTENTS Important Safety Instructions 2-3 Reversing Door 20-23 Installation Requirements 4-10 Accessories 24 Installed Dryer Dimensions 11 Español 25 Installation Instructions 12-19 137442700A (1104)
All about the Installation of your Dryer TABLE OF CONTENTS Important Safety Instructions 2-3 Reversing Door 20-23 Installation Requirements 4-10 Accessories 24 Installed Dryer Dimensions 11 Español 25 Installation Instructions 12-19 137442700A (1104)
Installation Instructions (All Languages)
Page 2
...for installation: • Adjustable pliers • Phillips, straight, & square bit screwdrivers • Adjustable wrench • Pipe wrench for gas supply (gas dryer) • LP-resistant thread tape (for future reference. Cartons covered with flexible plastic venting material. WHAT TO DO IF YOU SMELL GAS: ...8226; Do not try to the dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the...
...for installation: • Adjustable pliers • Phillips, straight, & square bit screwdrivers • Adjustable wrench • Pipe wrench for gas supply (gas dryer) • LP-resistant thread tape (for future reference. Cartons covered with flexible plastic venting material. WHAT TO DO IF YOU SMELL GAS: ...8226; Do not try to the dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the...
Installation Instructions (All Languages)
Page 3
...service cord with approved sealer and wrench tight Conversion kit for function Electrical Power House power turned on Dryer plugged in Final Checks Installation Instructions and Use and Care Guide read all instructions before initial operation Door Reversal ...possible injury or death. CAUTION CAUTION indicates a potentially hazardous situation which is the safety alert symbol. Obey all safety messages that follow this dryer. Installation Checklist Exhaust Venting Free-flowing, clear of lint buildup 4 inch (102 mm) rigid or semi-...
...service cord with approved sealer and wrench tight Conversion kit for function Electrical Power House power turned on Dryer plugged in Final Checks Installation Instructions and Use and Care Guide read all instructions before initial operation Door Reversal ...possible injury or death. CAUTION CAUTION indicates a potentially hazardous situation which is the safety alert symbol. Obey all safety messages that follow this dryer. Installation Checklist Exhaust Venting Free-flowing, clear of lint buildup 4 inch (102 mm) rigid or semi-...
Installation Instructions (All Languages)
Page 4
...neutral. See "Grounding requirements" in Electrical Installation section. 3-WIRE POWER SUPPLY CORD KIT (not supplied) 3-wire receptacle (NEMA type 10-30R) The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug...-30R or NEMA 14-30R receptacle to neutral unless it was manufactured for use with 30 amp. Use separately fused circuits for use with clothes dryers. POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. time delay fuses or circuit breakers. Individual 30...
...neutral. See "Grounding requirements" in Electrical Installation section. 3-WIRE POWER SUPPLY CORD KIT (not supplied) 3-wire receptacle (NEMA type 10-30R) The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug...-30R or NEMA 14-30R receptacle to neutral unless it was manufactured for use with 30 amp. Use separately fused circuits for use with clothes dryers. POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. time delay fuses or circuit breakers. Individual 30...
Installation Instructions (All Languages)
Page 5
... for test gauge connection, MUST be installed immediately upstream of the gas supply piping system at test pressures equal to the dryer. 6 The dryer MUST be isolated from the gas supply piping system during any circumstances, cut, remove, or bypass the grounding prong. plugged...piping system during any pressure testing of the gas supply connection to or less than 1/2 psig (3.45 kPa). 8 Connections for gas dryer CIRCUIT - Individual, properly polarized and grounded 15 amp. time delay fuse or circuit breaker. INSTALLATION REQUIREMENTS Electrical requirements for the gas...
... for test gauge connection, MUST be installed immediately upstream of the gas supply piping system at test pressures equal to the dryer. 6 The dryer MUST be isolated from the gas supply piping system during any circumstances, cut, remove, or bypass the grounding prong. plugged...piping system during any pressure testing of the gas supply connection to or less than 1/2 psig (3.45 kPa). 8 Connections for gas dryer CIRCUIT - Individual, properly polarized and grounded 15 amp. time delay fuse or circuit breaker. INSTALLATION REQUIREMENTS Electrical requirements for the gas...
Installation Instructions (All Languages)
Page 6
... of fire. WARNING FIRE HAZARD Failure to collapse, be easily crushed and trap lint. If your dryer. Also, ensure the present duct is free of any other obstruction. These conditions will obstruct clothes dryer airflow and increase the risk of insects and rodents. To avoid restricting the outlet, maintain... Use only 4 inch (102 mm) diameter rigid or flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is made up of 12 inches (30.5 cm) clearance between the vent hood and the ground or any lint prior to installing...
... of fire. WARNING FIRE HAZARD Failure to collapse, be easily crushed and trap lint. If your dryer. Also, ensure the present duct is free of any other obstruction. These conditions will obstruct clothes dryer airflow and increase the risk of insects and rodents. To avoid restricting the outlet, maintain... Use only 4 inch (102 mm) diameter rigid or flexible metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is made up of 12 inches (30.5 cm) clearance between the vent hood and the ground or any lint prior to installing...
Installation Instructions (All Languages)
Page 7
... creating a fire hazard as well as increase drying times. Use an approved vent hood to an exhaust outdoors. If the dryer is not exhausted outdoors, some fine lint will be connected to terminate the duct outdoors, and seal all joints with exhaust system...fittings MUST be exhausted outdoors. INSTALLATION REQUIREMENTS Exhaust system requirements, continued WARNING FIRE HAZARD A clothes dryer must be expelled into the laundry area. Do not exhaust dryer into the duct to come in the surrounding area. Regularly inspect the outdoor exhaust opening and in contact ...
... creating a fire hazard as well as increase drying times. Use an approved vent hood to an exhaust outdoors. If the dryer is not exhausted outdoors, some fine lint will be connected to terminate the duct outdoors, and seal all joints with exhaust system...fittings MUST be exhausted outdoors. INSTALLATION REQUIREMENTS Exhaust system requirements, continued WARNING FIRE HAZARD A clothes dryer must be expelled into the laundry area. Do not exhaust dryer into the duct to come in the surrounding area. Regularly inspect the outdoor exhaust opening and in contact ...
Installation Instructions (All Languages)
Page 8
... NOT be inspected and cleaned a minimum of water column, the system is too restrictive and the installation is acceptable. The more the dryer is used, the more often you should be higher than 0.75 inches of water column, the system is unacceptable. If the system ...installation. • Venting left with short, straight adapter and 90° elbow allows for 3.75" (9.5 cm) installation. • Venting upward with normal usage. Dryer vent elbows are available through an uninsulated area may expose the exhaust system to exhaust outlet of the exhaust system will cause an increase in...
... NOT be inspected and cleaned a minimum of water column, the system is too restrictive and the installation is acceptable. The more the dryer is used, the more often you should be higher than 0.75 inches of water column, the system is unacceptable. If the system ...installation. • Venting left with short, straight adapter and 90° elbow allows for 3.75" (9.5 cm) installation. • Venting upward with normal usage. Dryer vent elbows are available through an uninsulated area may expose the exhaust system to exhaust outlet of the exhaust system will cause an increase in...
Installation Instructions (All Languages)
Page 9
... outlet. 6 Installer MUST anchor this guide for other flammables are kept or stored. If the dryer is installed in a garage, it will come in this (1) dryer or (2) dryer mounted on pedestal to the floor with a maximum slope of 18 inches (45.7 cm) above the...4 Refer to previous sections in contact with no obstructions. Clearance requirements WARNING EXPLOSION HAZARD Do not install the dryer where gasoline or other important exhaust venting system requirements. 5 When installing a gas dryer into a mobile home, a provision must be 4 inches (10.16 cm) in death, explosion, ...
... outlet. 6 Installer MUST anchor this guide for other flammables are kept or stored. If the dryer is installed in a garage, it will come in this (1) dryer or (2) dryer mounted on pedestal to the floor with a maximum slope of 18 inches (45.7 cm) above the...4 Refer to previous sections in contact with no obstructions. Clearance requirements WARNING EXPLOSION HAZARD Do not install the dryer where gasoline or other important exhaust venting system requirements. 5 When installing a gas dryer into a mobile home, a provision must be 4 inches (10.16 cm) in death, explosion, ...
Installation Instructions (All Languages)
Page 10
... Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) * Dryer must be vented straight back to be unobstructed when a door is required. INSTALLATION REQUIREMENTS Clearance requirements, continued Installation in a Recess or Closet... 1 A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors. 2 No other fuel burning appliance shall be...
... Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) * Dryer must be vented straight back to be unobstructed when a door is required. INSTALLATION REQUIREMENTS Clearance requirements, continued Installation in a Recess or Closet... 1 A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors. 2 No other fuel burning appliance shall be...
Installation Instructions (All Languages)
Page 11
... depth. Using a quick-turn 90° elbow (right or down on optional pedestal floor line * To obtain these minimal depth dimensions, dryer must be vented straight back. 51.4" (131cm) to clear open door 30.3" (77cm)* to front of closed door INSTALLED DIMENSIONS 27.0" (68.5cm...) 36.0" (91.5cm) freestand dryer on floor floor line 51.25" (130cm) dryer mounted on freestanding dryer) adds approximately 0.75 in . (6.5 cm) to installation depth. 1Hot and cold inlet hose length approximately 43...
... depth. Using a quick-turn 90° elbow (right or down on optional pedestal floor line * To obtain these minimal depth dimensions, dryer must be vented straight back. 51.4" (131cm) to clear open door 30.3" (77cm)* to front of closed door INSTALLED DIMENSIONS 27.0" (68.5cm...) 36.0" (91.5cm) freestand dryer on floor floor line 51.25" (130cm) dryer mounted on freestanding dryer) adds approximately 0.75 in . (6.5 cm) to installation depth. 1Hot and cold inlet hose length approximately 43...
Installation Instructions (All Languages)
Page 12
...a qualified electrician. or an equipment grounding conductor must be installed onto power cord. Electrical shock can result if the dryer is properly grounded. Check with a licensed electrician if you 've installed on the appliance. 12 INSTALLATION INSTRUCTIONS Electrical installation The ...the cord can be pulled out of the receptacle for the proper power cord to a grounded metal, permanent wiring system; Electric dryer (USA) WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in doubt, call a licensed electrician. 3 ...
...a qualified electrician. or an equipment grounding conductor must be installed onto power cord. Electrical shock can result if the dryer is properly grounded. Check with a licensed electrician if you 've installed on the appliance. 12 INSTALLATION INSTRUCTIONS Electrical installation The ...the cord can be pulled out of the receptacle for the proper power cord to a grounded metal, permanent wiring system; Electric dryer (USA) WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in doubt, call a licensed electrician. 3 ...
Installation Instructions (All Languages)
Page 13
...of electrical shock by a qualified electrician. For a grounded, cord-connected dryer: 1 The dryer MUST be plugged into an appropriate outlet that is properly grounded. Electric dryer (Canada) WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result ... - Grounding type wall receptacle Do not, under any circumstances, cut, remove, or bypass the grounding prong. Gas dryer (USA and Canada) 1 The dryer is equipped with a three-prong (grounding) plug for electrical current. 2 Since your protection against shock hazard and should...
...of electrical shock by a qualified electrician. For a grounded, cord-connected dryer: 1 The dryer MUST be plugged into an appropriate outlet that is properly grounded. Electric dryer (Canada) WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result ... - Grounding type wall receptacle Do not, under any circumstances, cut, remove, or bypass the grounding prong. Gas dryer (USA and Canada) 1 The dryer is equipped with a three-prong (grounding) plug for electrical current. 2 Since your protection against shock hazard and should...
Installation Instructions (All Languages)
Page 14
.... 14 INSTALLATION INSTRUCTIONS Gas connection 1 Remove the shipping cap from gas pipe at the rear of the dryer. This valve should be located in the same room as the dryer and should be in the gas supply line to allow gas to L.P. WARNING EXPLOSION HAZARD NEVER test for... the connection. IMPORTANT DO NOT connect the dryer to flow through the gas line. Apply an approved thread sealer that allows ease of Dryer All connections must be wrench-tightened IMPORTANT The supply line must be equipped with a manometer....
.... 14 INSTALLATION INSTRUCTIONS Gas connection 1 Remove the shipping cap from gas pipe at the rear of the dryer. This valve should be located in the same room as the dryer and should be in the gas supply line to allow gas to L.P. WARNING EXPLOSION HAZARD NEVER test for... the connection. IMPORTANT DO NOT connect the dryer to flow through the gas line. Apply an approved thread sealer that allows ease of Dryer All connections must be wrench-tightened IMPORTANT The supply line must be equipped with a manometer....
Installation Instructions (All Languages)
Page 15
... COLD INLET HOSE TO WASHER 3 Momentarily turn on COLD supply and run some water into a bucket or container to washer. 2 Remove COLD inlet hose from dryer drum and inspect hose couplings for proper placement of your...
... COLD INLET HOSE TO WASHER 3 Momentarily turn on COLD supply and run some water into a bucket or container to washer. 2 Remove COLD inlet hose from dryer drum and inspect hose couplings for proper placement of your...
Installation Instructions (All Languages)
Page 16
...10 Turn on the "Y" connector and snug it by hand. then tighten it by hand; DIRECT CONNECTION OR WITH EXTENSION* WATER INLET ON DRYER COLD WATER SUPPLY HOSE TO WASHER *Laundry hose extension not included with pliers. Í NOTE Short extension available from the kit to the short... extension hose and snug it another 2/3 turn with dryer. 16 Extension hose must meet qualifications for use in laundry installation. 7 Thread the "Y" connector to the other outlet on the water...
...10 Turn on the "Y" connector and snug it by hand. then tighten it by hand; DIRECT CONNECTION OR WITH EXTENSION* WATER INLET ON DRYER COLD WATER SUPPLY HOSE TO WASHER *Laundry hose extension not included with pliers. Í NOTE Short extension available from the kit to the short... extension hose and snug it another 2/3 turn with dryer. 16 Extension hose must meet qualifications for use in laundry installation. 7 Thread the "Y" connector to the other outlet on the water...
Installation Instructions (All Languages)
Page 17
... the screw securing the terminal block access cover in the lower corner on the back of the dryer. 3 Install a UL-approved strain relief according to the terminal block. 17 Neutral terminal IMPORTANT If moving dryer from the center terminal back to the GREEN screw next to the power cord/strain relief manufacturer...
... the screw securing the terminal block access cover in the lower corner on the back of the dryer. 3 Install a UL-approved strain relief according to the terminal block. 17 Neutral terminal IMPORTANT If moving dryer from the center terminal back to the GREEN screw next to the power cord/strain relief manufacturer...
Installation Instructions (All Languages)
Page 18
... manufacturer's guidelines for 4-wire system. power cord, NEMA 14-30 type ST or SRDT, through the strain relief. 5 Disconnect the internal (BLACK) dryer harness ground wire from the (GREEN) ground screw next to the terminal block. 6 Attach the ground (GREEN) power cord wire to the cabinet with...Turn off power supply to outlet. 2 Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer. 3 Install a UL-approved strain relief according to the power cord/strain relief manufacturer's instructions in the terminal screw recovery slot below the access...
... manufacturer's guidelines for 4-wire system. power cord, NEMA 14-30 type ST or SRDT, through the strain relief. 5 Disconnect the internal (BLACK) dryer harness ground wire from the (GREEN) ground screw next to the terminal block. 6 Attach the ground (GREEN) power cord wire to the cabinet with...Turn off power supply to outlet. 2 Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer. 3 Install a UL-approved strain relief according to the power cord/strain relief manufacturer's instructions in the terminal screw recovery slot below the access...
Installation Instructions (All Languages)
Page 19
...General installation 1 Connect the exhaust duct to its final position. Use metal foil tape to seal all other joints. 2 Carefully slide the dryer to the outside exhaust system (see pages 6 through 8). Remove and discard door tape. It contains valuable and helpful information that will save you ...one or more of a 4" (102 mm) clamp (item A) is resting solidly on all four legs. Use of the legs until the dryer is recommended to connect the dryer to check A for service. 7 Place these instructions in your Use & Care Guide before plugging the power cord into an outlet. 3 Plug...
...General installation 1 Connect the exhaust duct to its final position. Use metal foil tape to seal all other joints. 2 Carefully slide the dryer to the outside exhaust system (see pages 6 through 8). Remove and discard door tape. It contains valuable and helpful information that will save you ...one or more of a 4" (102 mm) clamp (item A) is resting solidly on all four legs. Use of the legs until the dryer is recommended to connect the dryer to check A for service. 7 Place these instructions in your Use & Care Guide before plugging the power cord into an outlet. 3 Plug...
Installation Instructions (All Languages)
Page 20
... (no. 1-5) in place. 6 Locate the 2 pan head screws (no. 6-7) on the inner door nearest the metal strike and center of dryer or floor near dryer, with both hands, squarely lift door and hinge upward approximately 3/8" (10 mm) so "T" post on back of the inner door. Remove and ...save these 2 screws. 7 Separate inner door assembly from outer door assembly. 20 Remove lower screw first, then upper screw. 4 Gently place dryer door face down on flat, covered work surface, such as top of hinge (9 and 3 o'clock positions). Remove and save these 5 screws. 3 ...
... (no. 1-5) in place. 6 Locate the 2 pan head screws (no. 6-7) on the inner door nearest the metal strike and center of dryer or floor near dryer, with both hands, squarely lift door and hinge upward approximately 3/8" (10 mm) so "T" post on back of the inner door. Remove and ...save these 2 screws. 7 Separate inner door assembly from outer door assembly. 20 Remove lower screw first, then upper screw. 4 Gently place dryer door face down on flat, covered work surface, such as top of hinge (9 and 3 o'clock positions). Remove and save these 5 screws. 3 ...