EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON S5232F-ON and S5148F-ON
Page 45
... Guide for 25GbE fiber optic cables requires VxRail release 4.5.215 and later. Dell EMC Networking Switches Switches and OS versions Qty Item 2 Dell EMC Networking S5148F-ON leaf switches 1 Dell EMC Networking S3048-ON management switch OS Version 10.4.1.1 10.4.1.1 DAC Cables ...-3.0M DP/N 0VXFJY A.3 Note: VxRail support for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON A A.1 A.2 Validated components for S5148F-ON using VxRail 4.5 The following tables include the hardware, software, and firmware used to configure and validate the examples in this guide. Qty per node...
... Guide for 25GbE fiber optic cables requires VxRail release 4.5.215 and later. Dell EMC Networking Switches Switches and OS versions Qty Item 2 Dell EMC Networking S5148F-ON leaf switches 1 Dell EMC Networking S3048-ON management switch OS Version 10.4.1.1 10.4.1.1 DAC Cables ...-3.0M DP/N 0VXFJY A.3 Note: VxRail support for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON A A.1 A.2 Validated components for S5148F-ON using VxRail 4.5 The following tables include the hardware, software, and firmware used to configure and validate the examples in this guide. Qty per node...
EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON S5232F-ON and S5148F-ON
Page 47
...2x240GB SATA SSDs 1 Broadcom 57414 rNDC - 2x25GbE SFP28 ports - Dell EMC Networking switches Switches and operating systems versions Qty Item 2 Dell EMC Networking S5248F-ON leaf switches 2 Dell EMC Networking S5232F-ON leaf switches 1 Dell EMC Networking S3048-ON management switch operating systems version 10.4.2.0 10.... BIOS - iDRAC with Lifecycle Controller Firmware version 15.17.09.06 2.5.13.2008 20.08.04.03 1.4.8 3.21.21.21 47 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for S5248F-ON and S5232F-ON using the information that is provided...
...2x240GB SATA SSDs 1 Broadcom 57414 rNDC - 2x25GbE SFP28 ports - Dell EMC Networking switches Switches and operating systems versions Qty Item 2 Dell EMC Networking S5248F-ON leaf switches 2 Dell EMC Networking S5232F-ON leaf switches 1 Dell EMC Networking S3048-ON management switch operating systems version 10.4.2.0 10.... BIOS - iDRAC with Lifecycle Controller Firmware version 15.17.09.06 2.5.13.2008 20.08.04.03 1.4.8 3.21.21.21 47 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for S5248F-ON and S5232F-ON using the information that is provided...
Open Networking Hardware Diagnostic Guide December 2021
Page 5
... NOTE: This equipment contains optical transceivers, which comply with the limits of your Open Networking (-ON) switch, see the Dell EMC Networking OS10 Info Hub. Related documents For more information about your switch information site. Class 1 laser product tag NOTE... following documents at www.dell.com/support/. ● Dell EMC PowerSwitch Getting Started Guide or Dell EMC Setup Guide ● Dell EMC PowerSwitch Installation Guide ● Dell EMC PowerSwitch ONIE Release Notes ● Dell EMC PowerSwitch Firmware Updater Release Notes ● Dell EMC PowerSwitch DIAG OS and...
... NOTE: This equipment contains optical transceivers, which comply with the limits of your Open Networking (-ON) switch, see the Dell EMC Networking OS10 Info Hub. Related documents For more information about your switch information site. Class 1 laser product tag NOTE... following documents at www.dell.com/support/. ● Dell EMC PowerSwitch Getting Started Guide or Dell EMC Setup Guide ● Dell EMC PowerSwitch Installation Guide ● Dell EMC PowerSwitch ONIE Release Notes ● Dell EMC PowerSwitch Firmware Updater Release Notes ● Dell EMC PowerSwitch DIAG OS and...
Open Networking Hardware Diagnostic Guide December 2021
Page 10
... SCP, TFTP, or WGET (ftp/https). Confirm that messages display on your system must meet the following steps describe how to create a bootable unified extensible firmware interface (UEFI) ONIE-based USB to make a selection. The default baud rate for ONIE boot Pre-requisites The BIOS running at 115200 baud rate and...
... SCP, TFTP, or WGET (ftp/https). Confirm that messages display on your system must meet the following steps describe how to create a bootable unified extensible firmware interface (UEFI) ONIE-based USB to make a selection. The default baud rate for ONIE boot Pre-requisites The BIOS running at 115200 baud rate and...
Open Networking Hardware Diagnostic Guide December 2021
Page 13
... bits of entropy available Info: Mounting EFI System on : /dev/sda /proc/devices: No entry for device-mapper found ONIE: Success: Firmware update URL: file:///lib/onie/onie-updater ONIE: Success: Firmware update version: x.xx.x.x ONIE: Rebooting... Version : x.xx.x.x Build Date: 2016-04-26T09:14-0700 ONIE: OS Install Mode ... Verifying image...
... bits of entropy available Info: Mounting EFI System on : /dev/sda /proc/devices: No entry for device-mapper found ONIE: Success: Firmware update URL: file:///lib/onie/onie-updater ONIE: Success: Firmware update version: x.xx.x.x ONIE: Rebooting... Version : x.xx.x.x Build Date: 2016-04-26T09:14-0700 ONIE: OS Install Mode ... Verifying image...
Open Networking Hardware Diagnostic Guide December 2021
Page 38
... Commands for Sun servers kontronoem OEM Commands for Kontron devices picmg Run a PICMG/ATCA extended cmd fwum Update IPMC using Kontron OEM Firmware Update Manager firewall Configure Firmware Firewall 38 Dell EMC DAIG-OS tools Commands: raw Send a RAW IPMI request and print response i2c Send an I2C Primary Write-Read command and...
... Commands for Sun servers kontronoem OEM Commands for Kontron devices picmg Run a PICMG/ATCA extended cmd fwum Update IPMC using Kontron OEM Firmware Update Manager firewall Configure Firmware Firewall 38 Dell EMC DAIG-OS tools Commands: raw Send a RAW IPMI request and print response i2c Send an I2C Primary Write-Read command and...
Open Networking Hardware Diagnostic Guide December 2021
Page 39
... OEM Commands for Dell systems Launch interactive IPMI shell Run list of commands from file Set runtime variable for shell and exec Update HPM components using PICMG HPM.1 file run FRU-Ekeying analyzer using FRU files Update Intel Manageability Engine Firmware Run a VITA ...SDRs : no Additional Device Support : Sensor Device SDR Repository Device SEL Device FRU Inventory Device IPMB Event Receiver IPMB Event Generator Chassis Device Aux Firmware Rev Info : 0x00 0x00 0x00 0x00 Output sensor output root@dellemc-diag-os:~# ipmitool sensor PT_Mid_temp | 31.000 | degrees C | ok |...
... OEM Commands for Dell systems Launch interactive IPMI shell Run list of commands from file Set runtime variable for shell and exec Update HPM components using PICMG HPM.1 file run FRU-Ekeying analyzer using FRU files Update Intel Manageability Engine Firmware Run a VITA ...SDRs : no Additional Device Support : Sensor Device SDR Repository Device SEL Device FRU Inventory Device IPMB Event Receiver IPMB Event Generator Chassis Device Aux Firmware Rev Info : 0x00 0x00 0x00 0x00 Output sensor output root@dellemc-diag-os:~# ipmitool sensor PT_Mid_temp | 31.000 | degrees C | ok |...
Open Networking Hardware Diagnostic Guide December 2021
Page 63
...-diag-os:~# pltool DellEmc Diag - Programable Logic Tool version x.x, x.xx.x.x-x build, yyyy/mm/dd, Dell EMC DAIG-OS tools 63 full-duplex root@dellemc-diag-os:~# root@dellemc-diag-os:~# phytool --show-intf Settings for the correct firmware loads. The tool uses the SDI interface to get a list of devices and registers...
...-diag-os:~# pltool DellEmc Diag - Programable Logic Tool version x.x, x.xx.x.x-x build, yyyy/mm/dd, Dell EMC DAIG-OS tools 63 full-duplex root@dellemc-diag-os:~# root@dellemc-diag-os:~# phytool --show-intf Settings for the correct firmware loads. The tool uses the SDI interface to get a list of devices and registers...
Open Networking Hardware Diagnostic Guide December 2021
Page 75
SMART support is : Available - device has SMART capability. mSATA 3IE Serial Number: 20160119AA144700000F Firmware Version: S141002c User Capacity: 32,017,047,552 bytes [32.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device ... on the filesystems Output list output root@dell-diag-os:~# storagetool --list Mounted Filesystem Devices: /dev/sda3 / ext4 root@dell-diag-os:~# test output root@dell-diag-os:~# storagetool --test --dev=/dev/sda3 Testing Storage Devices Passed root@dell-diag-os:~# smart output root@dell-diag-os:~# storagetool --smart --dev=/dev...
SMART support is : Available - device has SMART capability. mSATA 3IE Serial Number: 20160119AA144700000F Firmware Version: S141002c User Capacity: 32,017,047,552 bytes [32.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device ... on the filesystems Output list output root@dell-diag-os:~# storagetool --list Mounted Filesystem Devices: /dev/sda3 / ext4 root@dell-diag-os:~# test output root@dell-diag-os:~# storagetool --test --dev=/dev/sda3 Testing Storage Devices Passed root@dell-diag-os:~# smart output root@dell-diag-os:~# storagetool --smart --dev=/dev...
Open Networking Hardware Diagnostic Guide December 2021
Page 78
...dev/hda (Enables SMART on |off ], wcreorder,[on first disk) smartctl --test=long /dev/hda (Executes extended disk self-test) 78 Dell EMC DAIG-OS tools -s VALUE, --smart=VALUE Enable/disable SMART on device (on/off) -o VALUE, --offlineauto=VALUE (ATA) Enable/... Attributes and values -f FORMAT, --format=FORMAT Set output format for vendor Attribute N (see man page) (ATA) -F TYPE, --firmwarebug=TYPE (ATA) Use firmware bug workaround: none, nologdir, samsung, samsung2, samsung3, xerrorlba, swapid -P TYPE, --presets=TYPE Drive-specific presets: use, ignore, show, showall (ATA) ...
...dev/hda (Enables SMART on |off ], wcreorder,[on first disk) smartctl --test=long /dev/hda (Executes extended disk self-test) 78 Dell EMC DAIG-OS tools -s VALUE, --smart=VALUE Enable/disable SMART on device (on/off) -o VALUE, --offlineauto=VALUE (ATA) Enable/... Attributes and values -f FORMAT, --format=FORMAT Set output format for vendor Attribute N (see man page) (ATA) -F TYPE, --firmwarebug=TYPE (ATA) Use firmware bug workaround: none, nologdir, samsung, samsung2, samsung3, xerrorlba, swapid -P TYPE, --presets=TYPE Drive-specific presets: use, ignore, show, showall (ATA) ...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 16
... yellow-Fan fault-including incompatible airflow direction when you insert the PSU or fan trays with five times on and off: Mismatch ● Flashing green-Firmware update ● Off-Locator function disabled ● Flashing blue-Locator function enabled ● Off-No power ● Solid green-Hex digit representing the stack unit...
... yellow-Fan fault-including incompatible airflow direction when you insert the PSU or fan trays with five times on and off: Mismatch ● Flashing green-Firmware update ● Off-Locator function disabled ● Flashing blue-Locator function enabled ● Off-No power ● Solid green-Hex digit representing the stack unit...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 43
...when replacing a switch, contact your rack or cabinet. NOTE: ESD damage can occur when components are replacing a different switch or non-Dell EMC switch. copy running -config 11. Label and remove all the cables. For detailed installation instructions, see ONIE information at www.onie....org. Switch replacement The following steps describe removing and replacing a switch with the firmware download. 10. Always wear an ESD-preventive wrist or heel ground strap when handling the switch and accessories. If you are ...
...when replacing a switch, contact your rack or cabinet. NOTE: ESD damage can occur when components are replacing a different switch or non-Dell EMC switch. copy running -config 11. Label and remove all the cables. For detailed installation instructions, see ONIE information at www.onie....org. Switch replacement The following steps describe removing and replacing a switch with the firmware download. 10. Always wear an ESD-preventive wrist or heel ground strap when handling the switch and accessories. If you are ...
EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Page 3
Contents Chapter 1: About this guide...4 Information symbols...4 Document revision history...5 Chapter 2: Hardware and software support 6 Chapter 3: Configuration methods 7 Configurations...9 Date and time...10 SNMP and email alerts...11 Add and delete users...13 Firewall...17 Event log...28 Default configuration restore...29 Chapter 4: Host power control...31 Chapter 5: Firmware update...32 Chapter 6: Access system health sensors 33 Chapter 7: IPMI commands...35 Chapter 8: ipmiutil package...38 Chapter 9: Access FRU data...39 Chapter 10: Dell EMC support...41 Contents 3
Contents Chapter 1: About this guide...4 Information symbols...4 Document revision history...5 Chapter 2: Hardware and software support 6 Chapter 3: Configuration methods 7 Configurations...9 Date and time...10 SNMP and email alerts...11 Add and delete users...13 Firewall...17 Event log...28 Default configuration restore...29 Chapter 4: Host power control...31 Chapter 5: Firmware update...32 Chapter 6: Access system health sensors 33 Chapter 7: IPMI commands...35 Chapter 8: ipmiutil package...38 Chapter 9: Access FRU data...39 Chapter 10: Dell EMC support...41 Contents 3
EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Page 32
... raw 0x32 0xaa 0x00 (Then wait 15s) Update Main BMC: ./Yafuflash -cd -mse 1 rom.ima Update BMC by default. 5 Firmware update To update the firmware from a remote machine, use only The BMC virtual USB is between the BMC and the microprocessor. When using the following command: ./Yafuflash... -nw -ip bmc_ip -u admin -p admin -mse 1 bmc.ima 32 Firmware update For more information about Yafuflash, see the S5200-ON Series Release Notes. Table 5. You can ping the BMC IP address. 2. The USB ...
... raw 0x32 0xaa 0x00 (Then wait 15s) Update Main BMC: ./Yafuflash -cd -mse 1 rom.ima Update BMC by default. 5 Firmware update To update the firmware from a remote machine, use only The BMC virtual USB is between the BMC and the microprocessor. When using the following command: ./Yafuflash... -nw -ip bmc_ip -u admin -p admin -mse 1 bmc.ima 32 Firmware update For more information about Yafuflash, see the S5200-ON Series Release Notes. Table 5. You can ping the BMC IP address. 2. The USB ...
EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Page 38
...technical-resources.html. ● ipmiutil-a metacommand to invoke each of the IPMI BMC. ○ ipmiutil hpm (ihpm)-hardware platform management (HPM) firmware update manager extensions ○ ipmiutil lan (ilan)-show and configure the local area network (LAN) port and platform event filter (PEF) table... to generate BMC LAN alerts using the firmware events. ○ ipmiutil picmg (ipicmg)-discover the available IPMI LAN nodes on a subnet. ○ ipmiutil fru (ifru)-show decoded field replaceable...
...technical-resources.html. ● ipmiutil-a metacommand to invoke each of the IPMI BMC. ○ ipmiutil hpm (ihpm)-hardware platform management (HPM) firmware update manager extensions ○ ipmiutil lan (ilan)-show and configure the local area network (LAN) port and platform event filter (PEF) table... to generate BMC LAN alerts using the firmware events. ○ ipmiutil picmg (ipicmg)-discover the available IPMI LAN nodes on a subnet. ○ ipmiutil fru (ifru)-show decoded field replaceable...