Hardware Owner's Manual
Page 19
... port Ethernet connector NOTE: The RAID controller module network configuration can be assigned using a DHCP server (the default setting). For detailed information on specific redundancy needs. The two iSCSI ports provide redundant host connections and support ... server is not available (time-out is 10 seconds) then the RAID controller modules uses the static IP addresses of the enclosure. Each RAID controller module provides data path and enclosure management functions for your enclosure... and states to hosts depending on cabling, see the PowerVault MD3000i Installation Guide.
... port Ethernet connector NOTE: The RAID controller module network configuration can be assigned using a DHCP server (the default setting). For detailed information on specific redundancy needs. The two iSCSI ports provide redundant host connections and support ... server is not available (time-out is 10 seconds) then the RAID controller modules uses the static IP addresses of the enclosure. Each RAID controller module provides data path and enclosure management functions for your enclosure... and states to hosts depending on cabling, see the PowerVault MD3000i Installation Guide.
Dell MD Storage Array vCenter Plug-in User’s Guide
Page 8
... a separate Windows 2003 or 2008 server from the Download and Drivers area at support.dell.com/manuals for the most current versions. The IP address will default to , or accept the default of 8084 and 8081, and click Next. 6 Change the IP address of the application server if desired. Click Next. 7 The next screen prompts...
... a separate Windows 2003 or 2008 server from the Download and Drivers area at support.dell.com/manuals for the most current versions. The IP address will default to , or accept the default of 8084 and 8081, and click Next. 6 Change the IP address of the application server if desired. Click Next. 7 The next screen prompts...
Command Line Interface Guide
Page 45
...properties of the storage array: • A detailed profile of the components and features in the storage array • The battery age • The default host type (which is the current host type) • Other available host types • The hot spare locations • The identifiers for enabled ...and physical component profiles • The time to see all of the information. You can also identify the storage array by the dummy IP address 123.45.67.89. The show storageArray profile command returns detailed information about the storage array, run the show storageArray command with ...
...properties of the storage array: • A detailed profile of the components and features in the storage array • The battery age • The default host type (which is the current host type) • Other available host types • The hot spare locations • The identifiers for enabled ...and physical component profiles • The time to see all of the information. You can also identify the storage array by the dummy IP address 123.45.67.89. The show storageArray profile command returns detailed information about the storage array, run the show storageArray command with ...
Command Line Interface Guide
Page 57
... destination and specify that event timestamps written by RAID controller modules to the Major Event Log (MEL) match event timestamps written to define the default host type. SMcli -a trap:public, 123.45.67.891 123.45.67.892 Setting the RAID Controller Module Clocks To synchronize the clocks... helps ensure that only event information is to be sent is 123.45.67.891. The following example shows how to set the mail server IP and the sender address configurations for SMTP alerts: SMcli -m 123.45.67.89 -F [email protected] or SMcli -m MyCompany.com -F MyStorageArrayEvent@...
... destination and specify that event timestamps written by RAID controller modules to the Major Event Log (MEL) match event timestamps written to define the default host type. SMcli -a trap:public, 123.45.67.891 123.45.67.892 Setting the RAID Controller Module Clocks To synchronize the clocks... helps ensure that only event information is to be sent is 123.45.67.891. The following example shows how to set the mail server IP and the sender address configurations for SMTP alerts: SMcli -m 123.45.67.89 -F [email protected] or SMcli -m MyCompany.com -F MyStorageArrayEvent@...
Command Line Interface Guide
Page 187
The default value is 49152 to 65535. NOTE: A listening port resides on a TCP/IP network. Example -c "set storageArray isnsListeningPort = integer Parameter Parameter isnsListeningPort Description The IP address that you want to use for the iSNS server listening port. The iSNS protocol also facilitates a seamless integration of IP and Fibre Channel .... The iSNS protocol provides intelligent storage discovery and management services comparable to those found in Fibre Channel networks, allowing a commodity IP network to function in a similar capacity as a storage area network.
The default value is 49152 to 65535. NOTE: A listening port resides on a TCP/IP network. Example -c "set storageArray isnsListeningPort = integer Parameter Parameter isnsListeningPort Description The IP address that you want to use for the iSNS server listening port. The iSNS protocol also facilitates a seamless integration of IP and Fibre Channel .... The iSNS protocol provides intelligent storage discovery and management services comparable to those found in Fibre Channel networks, allowing a commodity IP network to function in a similar capacity as a storage area network.
Installation Guide
Page 33
...0 B 192.168.130.101 (In 0 default) 192.168.131.101 (In 1 default) 192.168.128.101 (Mgmt network port) cntl. 1 MD3000i 192.168.128.102 (Mgmt network port) 192.168.131.102 (In 1 default) 192.168.130.102 (In 0 default) Target CHAP Secret If you need additional space... for each NIC) Default gateway iSCSI port 1 iSCSI port 2 iSCSI port 3 iSCSI port 4 Management port Management port B Static IP address (...
...0 B 192.168.130.101 (In 0 default) 192.168.131.101 (In 1 default) 192.168.128.101 (Mgmt network port) cntl. 1 MD3000i 192.168.128.102 (Mgmt network port) 192.168.131.102 (In 1 default) 192.168.130.102 (In 0 default) Target CHAP Secret If you need additional space... for each NIC) Default gateway iSCSI port 1 iSCSI port 2 iSCSI port 3 iSCSI port 4 Management port Management port B Static IP address (...
Installation Guide
Page 36
... be performed on the same IP subnet as the storage array. Automatic Storage Array Discovery 1 Launch MD Storage Manager. Closing the discovery status window before the discovery process completes will cancel the discovery process. The default IP configuration is: Controller 0: IP: 192.168.128.101 Subnet... Mask: 255.255.255.0 Controller 1: IP: 192.168.128.102 Subnet Mask: 255.255.255.0 NOTE: No default gateway is the first storage array to be set up...
... be performed on the same IP subnet as the storage array. Automatic Storage Array Discovery 1 Launch MD Storage Manager. Closing the discovery status window before the discovery process completes will cancel the discovery process. The default IP configuration is: Controller 0: IP: 192.168.128.101 Subnet... Mask: 255.255.255.0 Controller 1: IP: 192.168.128.102 Subnet Mask: 255.255.255.0 NOTE: No default gateway is the first storage array to be set up...
Installation Guide
Page 38
... for the selected array. Set up e-mail alerts. Although DHCP is supported, static IP addressing is recommended. NOTE: The Status area in the management console (default: "public"), and (2) a trap destination, IP address or host name of storage management stations set by administrator as an ASCII string in the Summary tab shows if alerts...
... for the selected array. Set up e-mail alerts. Although DHCP is supported, static IP addressing is recommended. NOTE: The Status area in the management console (default: "public"), and (2) a trap destination, IP address or host name of storage management stations set by administrator as an ASCII string in the Summary tab shows if alerts...
Installation Guide
Page 39
.... NOTE: IPv6 is supported only on the storage array. Step 2: Configure the iSCSI Ports on the Storage Array By default, the iSCSI ports on the storage array are set to the following IPv4 settings: Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask: 255.255.255.0 Port: 3260 Controller 0, Port...131.101 Subnet Mask: 255.255.255.0 Port: 3260 Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask: 255.255.255.0 Port: 3260 Controller 1, Port 1: IP: 192.168.131.102 Subnet Mask: 255.255.255.0 Port: 3260 NOTE: No default gateway is set to determine a network access priority. • TCP listening ...
.... NOTE: IPv6 is supported only on the storage array. Step 2: Configure the iSCSI Ports on the Storage Array By default, the iSCSI ports on the storage array are set to the following IPv4 settings: Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask: 255.255.255.0 Port: 3260 Controller 0, Port...131.101 Subnet Mask: 255.255.255.0 Port: 3260 Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask: 255.255.255.0 Port: 3260 Controller 1, Port 1: IP: 192.168.131.102 Subnet Mask: 255.255.255.0 Port: 3260 NOTE: No default gateway is set to determine a network access priority. • TCP listening ...
Installation Guide
Page 40
...enter CHAP information at this point, unless you plan to exit the Add Target Portals screen. 6 To exit the Discovery tab, click OK. The default is not supported. Click OK to exit the Advanced menu, and OK again to configure CHAP authentication, do not plan to a SAN that corresponds to..., repeat step 1 thorough step 6 (above) for all iSCSI ports on the storage array. Select the set to Microsoft iSCSI Initiator. • Source IP: The source IP address of the iSCSI port on the storage array. 4 If the iSCSI storage array uses a custom TCP port, change the Port number. Stop here...
...enter CHAP information at this point, unless you plan to exit the Add Target Portals screen. 6 To exit the Discovery tab, click OK. The default is not supported. Click OK to exit the Advanced menu, and OK again to configure CHAP authentication, do not plan to a SAN that corresponds to..., repeat step 1 thorough step 6 (above) for all iSCSI ports on the storage array. Select the set to Microsoft iSCSI Initiator. • Source IP: The source IP address of the iSCSI port on the storage array. 4 If the iSCSI storage array uses a custom TCP port, change the Port number. Stop here...
Installation Guide
Page 41
...performed by modifying the /etc/iscsi.conf file, which is installed by naming it to another name of your MD3000i has two iSCSI controllers (four iSCSI ports), you will need to add four IP addresses: DiscoveryAddress= DiscoveryAddress= DiscoveryAddress= DiscoveryAddress= If you install MD Storage Manager. To use the sample file ...included on the CD: 1 Save the default /etc/iscsi.conf file by default when you elect not to use the sample file on the CD, edit the existing default /etc/iscsi.conf file as shown in the previous example. 5 Edit (or add) ...
...performed by modifying the /etc/iscsi.conf file, which is installed by naming it to another name of your MD3000i has two iSCSI controllers (four iSCSI ports), you will need to add four IP addresses: DiscoveryAddress= DiscoveryAddress= DiscoveryAddress= DiscoveryAddress= If you install MD Storage Manager. To use the sample file ...included on the CD: 1 Save the default /etc/iscsi.conf file by default when you elect not to use the sample file on the CD, edit the existing default /etc/iscsi.conf file as shown in the previous example. 5 Edit (or add) ...
Installation Guide
Page 55
is the initiator name. They can be logged in to . is the IP address of a parameter. NOTE: , and are required. * * * An asterisk (*) represents the default value of the iSCSI port on the controller being logged in to a target at one session to be replaced with ...is 3260. is 0x2 to display the target list. For example, your logon command might look like this: iscsicli PersistentLoginTarget iqn.1984-05.com.dell:powervault.6001372000ffe333000000004672edf2 3260 T 192.168.130.101 * * * 0x2 0 Setting Up Your iSCSI Storage Array 55 This value allows more than one ...
is the initiator name. They can be logged in to . is the IP address of a parameter. NOTE: , and are required. * * * An asterisk (*) represents the default value of the iSCSI port on the controller being logged in to a target at one session to be replaced with ...is 3260. is 0x2 to display the target list. For example, your logon command might look like this: iscsicli PersistentLoginTarget iqn.1984-05.com.dell:powervault.6001372000ffe333000000004672edf2 3260 T 192.168.130.101 * * * 0x2 0 Setting Up Your iSCSI Storage Array 55 This value allows more than one ...
Installation Guide
Page 58
....131.101 Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP: 192.168.131.102 NOTE: The management station you are not IPv6 enabled. In-band management should now be set up for in-band management, you can enable IPv6 and begin step 1 below . NOTE: By default, the MD3000i host ports are using...
....131.101 Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP: 192.168.131.102 NOTE: The management station you are not IPv6 enabled. In-band management should now be set up for in-band management, you can enable IPv6 and begin step 1 below . NOTE: By default, the MD3000i host ports are using...
Installation Guide
Page 64
... click Properties. 4 Select Obtain DNS server address automatically or enter the preferred and alternate DNS server IP addresses and click OK. If using a Linux host network, the following IP address and enter the IP address, subnet mask, and default gateway addresses. Then click Manage network connections. 2 Right-click the network connection you are using...
... click Properties. 4 Select Obtain DNS server address automatically or enter the preferred and alternate DNS server IP addresses and click OK. If using a Linux host network, the following IP address and enter the IP address, subnet mask, and default gateway addresses. Then click Manage network connections. 2 Right-click the network connection you are using...
User's Guide
Page 16
... port, including its Internet Protocol (IP) address, subnetwork mask (subnet mask), and gateway. NOTE: In-band management is separate from an in the operating system or with data. NOTICE: Removing or manipulating an access virtual disk can be assigned using a DHCP server (the default setting). If you are using ...if a DHCP server is not available and the 10-second selection period times out, the RAID controller modules use the 192.168.128.102 static IP address. Out-of -band management see the Installation Guide. For in two ways: • Out-of-band management • In-band management...
... port, including its Internet Protocol (IP) address, subnetwork mask (subnet mask), and gateway. NOTE: In-band management is separate from an in the operating system or with data. NOTICE: Removing or manipulating an access virtual disk can be assigned using a DHCP server (the default setting). If you are using ...if a DHCP server is not available and the 10-second selection period times out, the RAID controller modules use the 192.168.128.102 static IP address. Out-of -band management see the Installation Guide. For in two ways: • Out-of-band management • In-band management...
User's Guide
Page 17
... network configuration- For more information, see "Configuring iSCSI" in -band and out-ofband storage arrays. NOTE: For Linux, set the default gateway to the IP address of the host. The Automatic Discovery process finds both in the Modular Disk 3000i Systems Installation Guide. This process requires specific identification ... packets are sent to 255.255.255.255. For Red Hat® Linux®, if no gateway exists on the network, set the default gateway so that uses in -band management with iSCSI, a session must be established between the initiator on the host server and the storage ...
... network configuration- For more information, see "Configuring iSCSI" in -band and out-ofband storage arrays. NOTE: For Linux, set the default gateway to the IP address of the host. The Automatic Discovery process finds both in the Modular Disk 3000i Systems Installation Guide. This process requires specific identification ... packets are sent to 255.255.255.255. For Red Hat® Linux®, if no gateway exists on the network, set the default gateway so that uses in -band management with iSCSI, a session must be established between the initiator on the host server and the storage ...
User's Guide
Page 27
...Enter the Community name. NOTE: The community name is an ASCII string that identifies a known set to the client directory as the Dell IT Assistant). DellMDStorageArray.mib can select this option only if the Information to send option is set of addresses configured to display SNMP alerts...included in the list of management consoles and is copied to Event + Profile or Event + Support. 4 Click Save. The default community name is the IP address or the host name of a Full or Management Station installation selection. You need only install an appropriate SNMP service and ...
...Enter the Community name. NOTE: The community name is an ASCII string that identifies a known set to the client directory as the Dell IT Assistant). DellMDStorageArray.mib can select this option only if the Information to send option is set of addresses configured to display SNMP alerts...included in the list of management consoles and is copied to Event + Profile or Event + Support. 4 Click Save. The default community name is the IP address or the host name of a Full or Management Station installation selection. You need only install an appropriate SNMP service and ...
User's Guide
Page 35
...MD3000i iSCSI Host Ports Use the configuration dialog for the iSCSI host ports to set the advanced parameters for the iSCSI target discovery. b Manually specify the configuration using one of the following methods: • IPv4 - Advanced iSCSI Host Ports Settings NOTE: Configuring the advanced iSCSI host ports settings is the default... automatically from the DHCP server, or refresh DHCP. • IPv6 - Enter the IP address, subnet mask, and gateway for the individual iSCSI host ports to set up the MD3000i iSCSI host ports to use with MD Support Manager, click the Support tab, then ...
...MD3000i iSCSI Host Ports Use the configuration dialog for the iSCSI host ports to set the advanced parameters for the iSCSI target discovery. b Manually specify the configuration using one of the following methods: • IPv4 - Advanced iSCSI Host Ports Settings NOTE: Configuring the advanced iSCSI host ports settings is the default... automatically from the DHCP server, or refresh DHCP. • IPv6 - Enter the IP address, subnet mask, and gateway for the individual iSCSI host ports to set up the MD3000i iSCSI host ports to use with MD Support Manager, click the Support tab, then ...
User's Guide
Page 16
... the host-to -controller interface, while commands and events travel through the management port Ethernet cables. If you are using a DHCP server (the default setting). However, if a DHCP server is not supported on setting up in the operating system or with data. For in -band-managed storage array...In-band management is not available and the 10-second selection period times out, the RAID controller modules use the 192.168.128.102 static IP address. Do not modify the access virtual disk either in -band and out-of -band management, commands and events are not using a DHCP...
... the host-to -controller interface, while commands and events travel through the management port Ethernet cables. If you are using a DHCP server (the default setting). However, if a DHCP server is not supported on setting up in the operating system or with data. For in -band-managed storage array...In-band management is not available and the 10-second selection period times out, the RAID controller modules use the 192.168.128.102 static IP address. Do not modify the access virtual disk either in -band and out-of -band management, commands and events are not using a DHCP...
User's Guide
Page 17
...storage array resides outside of the NIC. For Red Hat® Enterprise Linux®, if no gateway exists on the network, set the default gateway so that broadcast packets are sent to MD Storage Manager, click New in the Array Selector area. Automatic Discovery of the host....storage array. NOTE: Verify that allows you to choose the automatic or manual process to the MD Storage Array. including station IP address, subnet mask, and default gateway-is displayed that your host or management station network configuration- See "Starting or Restarting the HostAgent Software in Windows" ...
...storage array resides outside of the NIC. For Red Hat® Enterprise Linux®, if no gateway exists on the network, set the default gateway so that broadcast packets are sent to MD Storage Manager, click New in the Array Selector area. Automatic Discovery of the host....storage array. NOTE: Verify that allows you to choose the automatic or manual process to the MD Storage Array. including station IP address, subnet mask, and default gateway-is displayed that your host or management station network configuration- See "Starting or Restarting the HostAgent Software in Windows" ...