Getting Started Guide
Page 5
...combined for both simplex (single controller) and duplex (dual controller) array configurations. For more information, refer to the Dell PowerVault MD Systems Support Matrix at support.dell.com). • Support for easy serviceability Getting Started With Your System 3 Availability Features • Up to two active...need when setting up to obtain technical assistance. System Features This section describes the major hardware and software features of supporting sessions from 32 iSCSI initiators (16 hosts with redundant connections) simultaneously with multiple connections per session.
...combined for both simplex (single controller) and duplex (dual controller) array configurations. For more information, refer to the Dell PowerVault MD Systems Support Matrix at support.dell.com). • Support for easy serviceability Getting Started With Your System 3 Availability Features • Up to two active...need when setting up to obtain technical assistance. System Features This section describes the major hardware and software features of supporting sessions from 32 iSCSI initiators (16 hosts with redundant connections) simultaneously with multiple connections per session.
Getting Started Guide
Page 6
...sensors for monitoring ambient temperatures • Over-temperature shutdown protection capability • Configuration and monitoring via the MD Storage Manager software Supported Operating Systems Your system supports the following operating systems: • Microsoft® Windows® Storage Server 2003 R2 ...at support.dell.com. This document can be included within this document or as a separate document. • The Rack Installation Instructions included with Intel EM64T(2.6 kernel) For more information, refer to the Dell PowerVault MD Systems Support Matrix at support.dell.com. ...
...sensors for monitoring ambient temperatures • Over-temperature shutdown protection capability • Configuration and monitoring via the MD Storage Manager software Supported Operating Systems Your system supports the following operating systems: • Microsoft® Windows® Storage Server 2003 R2 ...at support.dell.com. This document can be included within this document or as a separate document. • The Rack Installation Instructions included with Intel EM64T(2.6 kernel) For more information, refer to the Dell PowerVault MD Systems Support Matrix at support.dell.com. ...
Getting Started Guide
Page 7
...documents. • Release notes or readme files may not be included to provide current updates to the system, software, and/or documentation. For more information. Installation CAUTION: Before performing the following procedure, read the updates first...managing your system. • The Dell PowerVault MD Systems Support Matrix at support.dell.com provides compatibility information, including servers, operating systems, controllers, software, and hardware configurations. • Updates are sometimes included with your system. Dell Enterprise Training and Certification is available;...
...documents. • Release notes or readme files may not be included to provide current updates to the system, software, and/or documentation. For more information. Installation CAUTION: Before performing the following procedure, read the updates first...managing your system. • The Dell PowerVault MD Systems Support Matrix at support.dell.com provides compatibility information, including servers, operating systems, controllers, software, and hardware configurations. • Updates are sometimes included with your system. Dell Enterprise Training and Certification is available;...
Hardware Owner's Manual
Page 4
... Service 46 Virtual Disk Copy 47 Using Snapshot and Disk Copy Together 48 Hardware Redundancy and Failover 48 Redundancy and Non-Redundancy 49 Multi-Path Software 49 4 Contents
... Service 46 Virtual Disk Copy 47 Using Snapshot and Disk Copy Together 48 Hardware Redundancy and Failover 48 Redundancy and Non-Redundancy 49 Multi-Path Software 49 4 Contents
Hardware Owner's Manual
Page 10
Physical disk NOTE: Dell recommends stopping all I /O activity from a failed, offline, or removed RAID controller module to its alternate RAID controller module (or from a failed iSCSI connection). Expansion enclosure management modules (EMMs) • Task-based configuration software (MD Storage Manager) • Optional...Support for up to 255 virtual disk copies per array • Optional virtual disk copy (premium feature), up to two PowerVault MD1000 expansion enclosures through SAS Out port connectors on the RAID controller modules • Online firmware updates (without taking the ...
Physical disk NOTE: Dell recommends stopping all I /O activity from a failed, offline, or removed RAID controller module to its alternate RAID controller module (or from a failed iSCSI connection). Expansion enclosure management modules (EMMs) • Task-based configuration software (MD Storage Manager) • Optional...Support for up to 255 virtual disk copies per array • Optional virtual disk copy (premium feature), up to two PowerVault MD1000 expansion enclosures through SAS Out port connectors on the RAID controller modules • Online firmware updates (without taking the ...
Hardware Owner's Manual
Page 11
... documentation is a graphic interface with your storage array. • The PowerVault MD3000i Installation Guide provides installation and configuration instructions for both software and hardware. • The PowerVault MD Storage Manager CLI Guide provides information about using the command line interface (CLI). • The Dell PowerVault MD3000i Resource CD provides documentation for configuration and management tools, as well...
... documentation is a graphic interface with your storage array. • The PowerVault MD3000i Installation Guide provides installation and configuration instructions for both software and hardware. • The PowerVault MD Storage Manager CLI Guide provides information about using the command line interface (CLI). • The Dell PowerVault MD3000i Resource CD provides documentation for configuration and management tools, as well...
Hardware Owner's Manual
Page 12
... Your PowerVault MD3000i - Each RAID controller module has two iSCSI In port connectors that the following are included to provide last-minute updates to the enclosure, software, and/or documentation. Getting Started With Your System - NOTE: Always check for updates on support.dell.com ... the host server. The iSCSI In port connectors are identified as RAID controller module 0 and RAID controller module 1 (see Figure 1-4). MD3000i Resource CD - Rack Installation Guide or Rack Installation Instructions - Rail kit • Any relevant documentation, including: - • Updates...
... Your PowerVault MD3000i - Each RAID controller module has two iSCSI In port connectors that the following are included to provide last-minute updates to the enclosure, software, and/or documentation. Getting Started With Your System - NOTE: Always check for updates on support.dell.com ... the host server. The iSCSI In port connectors are identified as RAID controller module 0 and RAID controller module 1 (see Figure 1-4). MD3000i Resource CD - Rack Installation Guide or Rack Installation Instructions - Rail kit • Any relevant documentation, including: - • Updates...
Hardware Owner's Manual
Page 34
... to specify a physical disk to fail without a virtual disk failure. If the controller encounters an error while accessing a peer disk, it is available, the RAID software automatically attempts to rebuild the data to correct the error. The requirements for a replacement physical disk are available, an automatic rebuild occurs when a new physical...
... to specify a physical disk to fail without a virtual disk failure. If the controller encounters an error while accessing a peer disk, it is available, the RAID software automatically attempts to rebuild the data to correct the error. The requirements for a replacement physical disk are available, an automatic rebuild occurs when a new physical...
Hardware Owner's Manual
Page 43
... first time you choose this type of configuration, all of the following conditions, only a single storage partition is required: • You have special software (such as clustering software) to the same storage array. Host Server-to-Virtual Disk Mapping The host server attached to all of a host group that shares access to...
... first time you choose this type of configuration, all of the following conditions, only a single storage partition is required: • You have special software (such as clustering software) to the same storage array. Host Server-to-Virtual Disk Mapping The host server attached to all of a host group that shares access to...
Hardware Owner's Manual
Page 47
... copy process top priority will slightly impact I /O load, the number of virtual disks in a storage array. When a virtual disk copy is in the storage management software are not supported. • Virtual disks to be used as the target virtual disk. Storage Management VSS Hardware Provider Tips: • The number of snapshot...
... copy process top priority will slightly impact I /O load, the number of virtual disks in a storage array. When a virtual disk copy is in the storage management software are not supported. • Virtual disks to be used as the target virtual disk. Storage Management VSS Hardware Provider Tips: • The number of snapshot...
Hardware Owner's Manual
Page 49
...to a virtual disk and establishes a preferred path to the PowerVault MD Storage Manager CLI Guide. Refer to the PowerVault MD3000i Installation Guide for redundant iSCSI connections and cabling. The multi-path software identifies the existence of how to cable your iSCSI connections, ...the configuration must be fully redundant. For the multi-path software to ensure that provides management of the redundant data path between your MD3000i and host server, establish communication by using the iSCSI software initiator on configuring your host servers for creating a successfully ...
...to a virtual disk and establishes a preferred path to the PowerVault MD Storage Manager CLI Guide. Refer to the PowerVault MD3000i Installation Guide for redundant iSCSI connections and cabling. The multi-path software identifies the existence of how to cable your iSCSI connections, ...the configuration must be fully redundant. For the multi-path software to ensure that provides management of the redundant data path between your MD3000i and host server, establish communication by using the iSCSI software initiator on configuring your host servers for creating a successfully ...
Hardware Owner's Manual
Page 50
...the owner of a virtual disk after moving a controller offline, replacing a controller, or configuring iSCSI connections. Because host-based multi-path software is configured for automatic failback, the data paths and virtual disks are restored to their original RAID controller module after the RAID controller ... and no data is removed from the preferred controller to the host server. • The host server has multi-path failover software installed, and it is created. Automatic failback occurs under the following conditions: • Data is protected by the preferred controller to...
...the owner of a virtual disk after moving a controller offline, replacing a controller, or configuring iSCSI connections. Because host-based multi-path software is configured for automatic failback, the data paths and virtual disks are restored to their original RAID controller module after the RAID controller ... and no data is removed from the preferred controller to the host server. • The host server has multi-path failover software installed, and it is created. Automatic failback occurs under the following conditions: • Data is protected by the preferred controller to...
Hardware Owner's Manual
Page 51
If you have clustering software installed on the MD3000i Resource CD under Product Documentation. Failover happens automatically (and transparently). As a result, the host server(s) never loses access through the preferred controller that owns...For more information on clustering, a link to clustering documentation is used only in the windows\utility directory of each node. If you have clustering software installed on the MD3000i Resource CD under Product Documentation. • Failover occurred due to either RAID controller module on the host server to access the storage array.
If you have clustering software installed on the MD3000i Resource CD under Product Documentation. Failover happens automatically (and transparently). As a result, the host server(s) never loses access through the preferred controller that owns...For more information on clustering, a link to clustering documentation is used only in the windows\utility directory of each node. If you have clustering software installed on the MD3000i Resource CD under Product Documentation. • Failover occurred due to either RAID controller module on the host server to access the storage array.
Hardware Owner's Manual
Page 75
... Your Enclosure 75 Before performing any of the following conditions exists: • Ambient temperature is too high. • External airflow is amber. • Systems management software issues a fan-related error message. • Fan status indicator indicates a problem with the fan. 5 Install a new power supply. Action Ensure that none of the components...
... Your Enclosure 75 Before performing any of the following conditions exists: • Ambient temperature is too high. • External airflow is amber. • Systems management software issues a fan-related error message. • Fan status indicator indicates a problem with the fan. 5 Install a new power supply. Action Ensure that none of the components...
Hardware Owner's Manual
Page 87
... the operating system to a system, usually by a second beep, and then a burst of memory when the system is located. Advanced Configuration and Power Interface. ANSI - Software designed to the configuration of tasks. American National Standards Institute. ASCII - A diagnostic message in a special section of three beeps is beep code 1-1-3. Ampere(s). American Standard...
... the operating system to a system, usually by a second beep, and then a burst of memory when the system is located. Advanced Configuration and Power Interface. ANSI - Software designed to the configuration of tasks. American National Standards Institute. ASCII - A diagnostic message in a special section of three beeps is beep code 1-1-3. Ampere(s). American Standard...
Hardware Owner's Manual
Page 90
A DMA channel allows certain types of translating Internet domain names, such as www.dell.com, into IP addresses, such as 143.166.83.200. Desktop Management Interface. A method of data transfer between RAM and a device... directory are called subdirectories. EMC - DMI - ERA - Electrostatic discharge. expansion bus - directory - Directories help keep related files organized on your system's software and hardware by collecting information about the system's components, such as NICs. 90 Glossary Each disk has a "root" directory. Additional directories that allows the...
A DMA channel allows certain types of translating Internet domain names, such as www.dell.com, into IP addresses, such as 143.166.83.200. Desktop Management Interface. A method of data transfer between RAM and a device... directory are called subdirectories. EMC - DMI - ERA - Electrostatic discharge. expansion bus - directory - Directories help keep related files organized on your system's software and hardware by collecting information about the system's components, such as NICs. 90 Glossary Each disk has a "root" directory. Additional directories that allows the...
Hardware Owner's Manual
Page 94
...when a current is freely available; Media Access Control address. Megabit(s); 1,048,576 bits. LAN - however, the full distribution of hardware systems. Linux is open source software, which is passed through it. See also bus. Low voltage differential. Milliampere(s). mAh - MBR - Master boot record. 94 Glossary Liquid crystal display. Mbps - ...LAN is often rounded to the same building or a few nearby buildings, with local-bus expansion capability, certain peripheral devices (such as Red Hat® Software. LCD - LED - Linux - local bus - MBps -
...when a current is freely available; Media Access Control address. Megabit(s); 1,048,576 bits. LAN - however, the full distribution of hardware systems. Linux is open source software, which is passed through it. See also bus. Low voltage differential. Milliampere(s). mAh - MBR - Master boot record. 94 Glossary Liquid crystal display. Mbps - ...LAN is often rounded to the same building or a few nearby buildings, with local-bus expansion capability, certain peripheral devices (such as Red Hat® Software. LCD - LED - Linux - local bus - MBps -
Hardware Owner's Manual
Page 95
...that are optimized to the system board. Megahertz. ms - Millisecond(s). NAS systems have their own operating systems, integrated hardware, and software that connects to serve specific storage needs. Glossary 95 MHz - mirroring - NAS is used for maintaining the date, time, and...A device that does not lose its contents when you turn off your system that stores basic system data. NVRAM - Memory that is provided by software. Nonvolatile random-access memory. mm - Millimeter(s). NIC - NMI - NAS - NTFS - memory module - MS-DOS® - A device sends...
...that are optimized to the system board. Megahertz. ms - Millisecond(s). NAS systems have their own operating systems, integrated hardware, and software that connects to serve specific storage needs. Glossary 95 MHz - mirroring - NAS is used for maintaining the date, time, and...A device that does not lose its contents when you turn off your system that stores basic system data. NVRAM - Memory that is provided by software. Nonvolatile random-access memory. mm - Millimeter(s). NIC - NMI - NAS - NTFS - memory module - MS-DOS® - A device sends...
Hardware Owner's Manual
Page 96
... operating system loads when you to 4 GB • Multitasking • Virtual memory, a method for one processor must format each logical disk with the fdisk command. Software written for increasing addressable memory by the number of 16 MB to remove the processor chip. An operating mode that allows operating systems to implement...
... operating system loads when you to 4 GB • Multitasking • Virtual memory, a method for one processor must format each logical disk with the fdisk command. Software written for increasing addressable memory by the number of 16 MB to remove the processor chip. An operating mode that allows operating systems to implement...
Hardware Owner's Manual
Page 97
... - A storage enclosure supporting RAID via a LAN (without a physical disk or bootable diskette). RAID array - Collection of independent disks. RAM - RAS - A text file, usually shipped with software or hardware, that initiates your system. PS/2 - A way of code in ROM code. Redundant array of storage disks managed under a RAID solution. A method of RAID...
... - A storage enclosure supporting RAID via a LAN (without a physical disk or bootable diskette). RAID array - Collection of independent disks. RAM - RAS - A text file, usually shipped with software or hardware, that initiates your system. PS/2 - A way of code in ROM code. Redundant array of storage disks managed under a RAID solution. A method of RAID...