Product Manual
Page 3
Table of Contents D-Link Web Smart Switch User Manual Table of Contents Table of Contents ...i About This Guide...1 Terms/Usage...1 Copyright and Trademarks ...1 Product Introduction ...2 DES-1210-08P ...3 Front Panel ...3 Rear Panel...3 DES-1210-28 ...3 Front Panel ...3 Rear Panel...4 DES-1210-28P ...4 Front Panel ...4 Rear Panel...5 DES-1210-52 ...5 Front Panel ...5 Rear Panel...6 Hardware Installation ...7 Step 1: Unpacking...7 Step 2: Switch Installation...7 Desktop...
Table of Contents D-Link Web Smart Switch User Manual Table of Contents Table of Contents ...i About This Guide...1 Terms/Usage...1 Copyright and Trademarks ...1 Product Introduction ...2 DES-1210-08P ...3 Front Panel ...3 Rear Panel...3 DES-1210-28 ...3 Front Panel ...3 Rear Panel...4 DES-1210-28P ...4 Front Panel ...4 Rear Panel...5 DES-1210-52 ...5 Front Panel ...5 Rear Panel...6 Hardware Installation ...7 Step 1: Unpacking...7 Step 2: Switch Installation...7 Desktop...
Product Manual
Page 4
......25 Firmware Backup and Upload ...25 Tool Bar > Smart Wizard...26 Tool Bar > Online Help...26 Function Tree ...28 Device Information...28 System > System Settings ...29 System > DHCP Auto Configuration ...29 System > Trap Settings (For SmartConsole 29 System > ... Surveillance VLAN Settings 40 Configuration > Link Aggregation > Port Trunking 41 Configuration > Link Aggregation > LACP Port Settings 42 Configuration > IGMP Snooping ...43 Configuration > Multicast Filtering Mode (For DES-1210-08P only 44 Configuration > Multicast Filtering Mode (For DES-1210-28/28P/52 45 Configuration > Port...
......25 Firmware Backup and Upload ...25 Tool Bar > Smart Wizard...26 Tool Bar > Online Help...26 Function Tree ...28 Device Information...28 System > System Settings ...29 System > DHCP Auto Configuration ...29 System > Trap Settings (For SmartConsole 29 System > ... Surveillance VLAN Settings 40 Configuration > Link Aggregation > Port Trunking 41 Configuration > Link Aggregation > LACP Port Settings 42 Configuration > IGMP Snooping ...43 Configuration > Multicast Filtering Mode (For DES-1210-08P only 44 Configuration > Multicast Filtering Mode (For DES-1210-28/28P/52 45 Configuration > Port...
Product Manual
Page 9
...no PD found. Reset: By pressing the Reset button the Switch will change back to a power source. Port Link/Act/Speed LED (1-24): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port. When a port has amber light indicates that on /off indicates this port. And ... and 2 Combo SFP Web Smart Switch Front Panel Figure 3 - Fan OK/Fail LED: The FAN LED shows the status of power adapter. DES-1210-28 24-Port 10/100Mpbs with solid green indicate the corresponding port is running on 100M. Solid amber indicates a PoE error has occurred at this port...
...no PD found. Reset: By pressing the Reset button the Switch will change back to a power source. Port Link/Act/Speed LED (1-24): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port. When a port has amber light indicates that on /off indicates this port. And ... and 2 Combo SFP Web Smart Switch Front Panel Figure 3 - Fan OK/Fail LED: The FAN LED shows the status of power adapter. DES-1210-28 24-Port 10/100Mpbs with solid green indicate the corresponding port is running on 100M. Solid amber indicates a PoE error has occurred at this port...
Product Manual
Page 10
...green light (OK) indicates that port is running on 10M or 100M. NOTE: On DES-1210-28, the MiniGBIC ports are working abnormally. Blinking indicates that on 10M. DES-1210-28 Rear Panel Power: The power port is either sending or receiving data to the default configuration... SFP Web Smart Switch Front Panel Figure 5 - 1 Product Introduction D-Link Web Smart Switch User Manual Port Link/Act/Speed LED (25F, 26F, 25T, 26T, 27, 28): The Link/Act/Speed LED flashes which indicate a network link through the corresponding port. Rear Panel Figure 4 - Solid amber indicates ...
...green light (OK) indicates that port is running on 10M or 100M. NOTE: On DES-1210-28, the MiniGBIC ports are working abnormally. Blinking indicates that on 10M. DES-1210-28 Rear Panel Power: The power port is either sending or receiving data to the default configuration... SFP Web Smart Switch Front Panel Figure 5 - 1 Product Introduction D-Link Web Smart Switch User Manual Port Link/Act/Speed LED (25F, 26F, 25T, 26T, 27, 28): The Link/Act/Speed LED flashes which indicate a network link through the corresponding port. Rear Panel Figure 4 - Solid amber indicates ...
Product Manual
Page 11
...50F, 49T, 50T, 51, 52): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port. When the MiniGBIC port is used . When a port has amber light indicates that port is connected to the port. NOTE: On DES-1210-28P, the MiniGBIC ports are shared with normal...port cannot be used , the RJ-45 port 5 1 Product Introduction D-Link Web Smart Switch User Manual Port LED (25F, 26F, 25T, 26T, 27, 28): The Port LED flashes which indicates a network link through the corresponding port. DES-1210-28P Rear Panel Power: The power port is running on 1000M. When it...
...50F, 49T, 50T, 51, 52): The Link/Act/Speed LED flashes which indicates a network link through the corresponding port. When the MiniGBIC port is used . When a port has amber light indicates that port is connected to the port. NOTE: On DES-1210-28P, the MiniGBIC ports are shared with normal...port cannot be used , the RJ-45 port 5 1 Product Introduction D-Link Web Smart Switch User Manual Port LED (25F, 26F, 25T, 26T, 27, 28): The Port LED flashes which indicates a network link through the corresponding port. DES-1210-28P Rear Panel Power: The power port is running on 1000M. When it...
Product Manual
Page 15
Figure 13 - When power is to be unplugged in . 9 Plugging DES-1210-28/28P/52 into an outlet CAUTION: Do not turn on the power switch of power failure. Power surge may cause damage to the outside plant. ...CAUTION: The installation instructions clearly state that the ITE is resumed, plug the switch back in case of DES-1210-08P before power cables are connected. Plugging the DES-1210-08P into an outlet Power Failure As a precaution, the switch should be connected only to PoE networks without routing to the...
Figure 13 - When power is to be unplugged in . 9 Plugging DES-1210-28/28P/52 into an outlet CAUTION: Do not turn on the power switch of power failure. Power surge may cause damage to the outside plant. ...CAUTION: The installation instructions clearly state that the ITE is resumed, plug the switch back in case of DES-1210-08P before power cables are connected. Plugging the DES-1210-08P into an outlet Power Failure As a precaution, the switch should be connected only to PoE networks without routing to the...
Product Manual
Page 51
...be forwarded based on the register table and the unregister group will be flooded to all ports into port mirroring. 5 Configuration D-Link Web Smart Switch User Manual Figure 79 - Forward All Groups: The multicast stream will be studied. Forward Unregistered Groups: The ...off the mirroring of the VLAN for IGMP group per VLAN basis. Configuration > Multicast Filtering Mode Configuration > Multicast Filtering Mode (For DES-1210-28/28P/52) The Multicast Filtering Mode function allows users to better monitor network performances. Figure 80 - The Loopback 45 This enables network...
...be forwarded based on the register table and the unregister group will be flooded to all ports into port mirroring. 5 Configuration D-Link Web Smart Switch User Manual Figure 79 - Forward All Groups: The multicast stream will be studied. Forward Unregistered Groups: The ...off the mirroring of the VLAN for IGMP group per VLAN basis. Configuration > Multicast Filtering Mode Configuration > Multicast Filtering Mode (For DES-1210-28/28P/52) The Multicast Filtering Mode function allows users to better monitor network performances. Figure 80 - The Loopback 45 This enables network...
Product Manual
Page 56
...Change Notification (TCN) is disabled), the threshold can lose edge port status if a topology change . Click Refresh to -point (P2P) shared link. Threshold: If storm control is enabled (default is a BPDU that the port does not have p2p status whenever possible and operate as if...p2p status changes to True, it automatically loses edge port status. The default value is False. If set the restricted TCN of 64Kbps. For DES-1210-28/28P/52, the threshold is from Broadcast Only, Multicast & Broadcast, and Multicast & Broadcast & Unknown Unicast. QoS > Storm Control The Storm...
...Change Notification (TCN) is disabled), the threshold can lose edge port status if a topology change . Click Refresh to -point (P2P) shared link. Threshold: If storm control is enabled (default is a BPDU that the port does not have p2p status whenever possible and operate as if...p2p status changes to True, it automatically loses edge port status. The default value is False. If set the restricted TCN of 64Kbps. For DES-1210-28/28P/52, the threshold is from Broadcast Only, Multicast & Broadcast, and Multicast & Broadcast & Unknown Unicast. QoS > Storm Control The Storm...
Product Manual
Page 57
... that require a larger bandwidth or that allows network administrators to receiving, transmitting, or both receiving and transmitting packets. NOTE: For DES-1210-28/28P/52, the TX rate for the selected port. If any other value is used, the system automatically rounds it down menu...status of Quality of Service priority levels of 1850kbps. 5 Configuration D-Link Web Smart Switch User Manual Figure 88 - QoS > Bandwidth Control From Port / To Port: A consecutive group of 1850. Enabled disables the limit. For DES-1210-08P, the value is applied to reserve bandwidth for the selected...
... that require a larger bandwidth or that allows network administrators to receiving, transmitting, or both receiving and transmitting packets. NOTE: For DES-1210-28/28P/52, the TX rate for the selected port. If any other value is used, the system automatically rounds it down menu...status of Quality of Service priority levels of 1850kbps. 5 Configuration D-Link Web Smart Switch User Manual Figure 88 - QoS > Bandwidth Control From Port / To Port: A consecutive group of 1850. Enabled disables the limit. For DES-1210-08P, the value is applied to reserve bandwidth for the selected...
Product Manual
Page 81
...Tagging) 75 Appendix B - Technical Specifications D-Link Web Smart Switch User Manual Appendix B - DES-1210-08P: 1.19Mpps - Supports Full-Duplex operations 4 1000Base-T ports of DES-1210-28/28P /52 comply with the following standards...Link Aggregation: - DES-1210-08P : 1.6Gbps - IEEE 802.3af (DES-1210-08P/28P only) - IEEE 802.3u - DEM-312GT2 (1000BASE-SX, 2km) - DEM-211 (100BASE-FX, 2km) WDM Transceivers Supported: - DES-1210-28: 12.8Gbps - DES-1210-28: 9.5Mpps - DEM-314GT (1000BASE-LH, 50km) - DES-1210-08P/28/28P/52: 10~95% RH Storage Humidity: - DES-1210...
...Tagging) 75 Appendix B - Technical Specifications D-Link Web Smart Switch User Manual Appendix B - DES-1210-08P: 1.19Mpps - Supports Full-Duplex operations 4 1000Base-T ports of DES-1210-28/28P /52 comply with the following standards...Link Aggregation: - DES-1210-08P : 1.6Gbps - IEEE 802.3af (DES-1210-08P/28P only) - IEEE 802.3u - DEM-312GT2 (1000BASE-SX, 2km) - DEM-211 (100BASE-FX, 2km) WDM Transceivers Supported: - DES-1210-28: 12.8Gbps - DES-1210-28: 9.5Mpps - DEM-314GT (1000BASE-LH, 50km) - DES-1210-08P/28/28P/52: 10~95% RH Storage Humidity: - DES-1210...