Instruction Manual
Page 3
... your own household. 1 After you have read this manual before you purchasing the Canon Document Scanner DR-5020/5080C. Read this manual (DR-5020/5080C Instructions) and the separate Scanning Utility 5000 Instructions and ISIS/TWAIN Driver Instructions. This manual describes handling of the scanner, for anything other than your own personal use or use within the confines...
... your own household. 1 After you have read this manual before you purchasing the Canon Document Scanner DR-5020/5080C. Read this manual (DR-5020/5080C Instructions) and the separate Scanning Utility 5000 Instructions and ISIS/TWAIN Driver Instructions. This manual describes handling of the scanner, for anything other than your own personal use or use within the confines...
Instruction Manual
Page 4
... reading this manual, read the following symbols and indications. I This Unit This manual refers to the scanner specifically by DR-5020 and DR-5080C. 2 A number enclosed in this manual refers to the DR-5020 and DR-5080C collectively as the "scanner." CONVENTIONS This manual uses the following and familiarize yourself with their meanings. HINT Tips about the previous...
... reading this manual, read the following symbols and indications. I This Unit This manual refers to the scanner specifically by DR-5020 and DR-5080C. 2 A number enclosed in this manual refers to the DR-5020 and DR-5080C collectively as the "scanner." CONVENTIONS This manual uses the following and familiarize yourself with their meanings. HINT Tips about the previous...
Instruction Manual
Page 5
CONTENTS INTRODUCTION 1 CONVENTIONS 2 Safety Precautions 6 Chapter 1 About DR-5020/5080C 11 1.1 Features of DR-5020/5080C 12 1.2 Packaging: What's in the Box 14 1.3 Part Names 15 N Front view 15 N Rear view 16 N Operation panel 17 N Removable tray 20 N Document eject support plate 20 N Function key labels 20 Chapter 2 Preparation Before Use 21 2.1 System Requirements 22 2.2 Installation...
CONTENTS INTRODUCTION 1 CONVENTIONS 2 Safety Precautions 6 Chapter 1 About DR-5020/5080C 11 1.1 Features of DR-5020/5080C 12 1.2 Packaging: What's in the Box 14 1.3 Part Names 15 N Front view 15 N Rear view 16 N Operation panel 17 N Removable tray 20 N Document eject support plate 20 N Function key labels 20 Chapter 2 Preparation Before Use 21 2.1 System Requirements 22 2.2 Installation...
Instruction Manual
Page 11
... as shown in electrical shock. 9 If you use an extension cable, pay attention to the total amperage of the cable. • If you move the DR-5020/5080C, hold it . • Never bundle the power cord or wrap the cord around the power outlet free of obstacles. About the Power Supply •...; Be sure to connect to a AC 220-240V (50/60 Hz)/AC 120V (60 Hz) power supply. • Ensure that the scanner is connected to the power supply, contact your store of purchase or your fingers and cause unexpected injuries. WARNING Before you are unsure of anything...
... as shown in electrical shock. 9 If you use an extension cable, pay attention to the total amperage of the cable. • If you move the DR-5020/5080C, hold it . • Never bundle the power cord or wrap the cord around the power outlet free of obstacles. About the Power Supply •...; Be sure to connect to a AC 220-240V (50/60 Hz)/AC 120V (60 Hz) power supply. • Ensure that the scanner is connected to the power supply, contact your store of purchase or your fingers and cause unexpected injuries. WARNING Before you are unsure of anything...
Instruction Manual
Page 12
Chapter 1 About DR-5020/5080C This chapter describes the features of the scanner, what's in the box, and the names and functions of parts on the scanner. 1.1 Features of DR-5020/5080C 12 1.2 Packaging: What's in the Box? ........ 14 1.3 Part Names 15
Chapter 1 About DR-5020/5080C This chapter describes the features of the scanner, what's in the box, and the names and functions of parts on the scanner. 1.1 Features of DR-5020/5080C 12 1.2 Packaging: What's in the Box? ........ 14 1.3 Part Names 15
Instruction Manual
Page 13
...a service life of up to A3/11" x 17"-size documents can be scanned at once. - A wide range of size and thickness of documents can be scanned. Chapter 1 About DR-5020/5080C Features of DR-5020/5080C The DR-5020/5080C are fed and output from control panel or by the ...application. G High speed scanning Small documents such as it passes through to 6 million scans. G Easy operation Documents are versatile document image scanners...
...a service life of up to A3/11" x 17"-size documents can be scanned at once. - A wide range of size and thickness of documents can be scanned. Chapter 1 About DR-5020/5080C Features of DR-5020/5080C The DR-5020/5080C are fed and output from control panel or by the ...application. G High speed scanning Small documents such as it passes through to 6 million scans. G Easy operation Documents are versatile document image scanners...
Instruction Manual
Page 14
...the instruction manuals for the application and scanner driver in use . Optional memory may need to be added on depending on the scanning mode. G Various options The wide range of options includes the imprinter for printing characters on the document being scanned, bar code decoder for ...reading bar codes in the document. G Drop-out color (DR-5080C) This function disables drop-out scanning of DR-5020/5080C G Simple color or black-and-white gray-scale output (DR-5080C) Besides black-and-white 2-bit...
...the instruction manuals for the application and scanner driver in use . Optional memory may need to be added on depending on the scanning mode. G Various options The wide range of options includes the imprinter for printing characters on the document being scanned, bar code decoder for ...reading bar codes in the document. G Drop-out color (DR-5080C) This function disables drop-out scanning of DR-5020/5080C G Simple color or black-and-white gray-scale output (DR-5080C) Besides black-and-white 2-bit...
Instruction Manual
Page 15
... Utility 5000 Instructions ISIS/TWAIN Driver Instructions Function sheets Warranty card*2 Function key labels 14 Removable tray Document eject support plate Power cord*1 *1 The power cord varies according to country of purchase. Chapter 1 About DR-5020/5080C Packaging: What's in the Box? Check every item you have removed from the box. Make sure...
... Utility 5000 Instructions ISIS/TWAIN Driver Instructions Function sheets Warranty card*2 Function key labels 14 Removable tray Document eject support plate Power cord*1 *1 The power cord varies according to country of purchase. Chapter 1 About DR-5020/5080C Packaging: What's in the Box? Check every item you have removed from the box. Make sure...
Instruction Manual
Page 16
... wire Open out this cover when you are adjusting the print position of the document you are also displayed here. Open out the extension wire when you are loading large-size documents. Power switch Turns the scanner power ON and OFF. The number of each part. Part Names 1.3 Part ... tray extension/stopper This tray prevents large-size scanned documents from flying out of the paper surface. Do not exert unnecessary force to open the upper unit. N Front view Imprinter cover Open out this extension when you connect the DR-5020/5080C, take a few minutes to scan. The ...
... wire Open out this cover when you are adjusting the print position of the document you are also displayed here. Open out the extension wire when you are loading large-size documents. Power switch Turns the scanner power ON and OFF. The number of each part. Part Names 1.3 Part ... tray extension/stopper This tray prevents large-size scanned documents from flying out of the paper surface. Do not exert unnecessary force to open the upper unit. N Front view Imprinter cover Open out this extension when you connect the DR-5020/5080C, take a few minutes to scan. The ...
Instruction Manual
Page 17
Connector shape: D-sub half-pitch 50-pin (pin type) To avoid overheating and causing a fire, never block the air vents on the rear of the scanner. CAUTION 16 SCSI connectors Connect the SCSI connectors to this connector. Chapter 1 About DR-5020/5080C N Rear view Air vent DIP switch This switch is for setting the SCSI ID and turning the terminator ON or OFF. (P.25) Power cord connector Connect the power cord provided with the scanner to these connectors.
Connector shape: D-sub half-pitch 50-pin (pin type) To avoid overheating and causing a fire, never block the air vents on the rear of the scanner. CAUTION 16 SCSI connectors Connect the SCSI connectors to this connector. Chapter 1 About DR-5020/5080C N Rear view Air vent DIP switch This switch is for setting the SCSI ID and turning the terminator ON or OFF. (P.25) Power cord connector Connect the power cord provided with the scanner to these connectors.
Instruction Manual
Page 19
... can set the count start instruction from the computer. Auto: The scanner automatically feeds the document when you press the Start key after loading the document. Chapter 1 About DR-5020/5080C (3)Mode Selection key Select the document scanning mode. ("Black and white/Black and white error diffusion") Text...the application and the scan mode is lighting, when scanning the text documents (including mostly characters) with black and white error diffusion mode. Semi-Auto: The scanner feeds the document when you load the document. If any applications are all out. If the scan mode is...
... can set the count start instruction from the computer. Auto: The scanner automatically feeds the document when you press the Start key after loading the document. Chapter 1 About DR-5020/5080C (3)Mode Selection key Select the document scanning mode. ("Black and white/Black and white error diffusion") Text...the application and the scan mode is lighting, when scanning the text documents (including mostly characters) with black and white error diffusion mode. Semi-Auto: The scanner feeds the document when you load the document. If any applications are all out. If the scan mode is...
Instruction Manual
Page 21
... About DR-5020/5080C N Removable tray This tray can be installed on the document eject tray to prevent short-length documents from flying out of the tray when they are provided: a label describing which function is registered to the function key and a label for fixing on the document eject... tray and curling. N Function key labels Two labels are ejected from becoming caught on the document tray as the document guide. This plate prevents such documents from the scanner. N Document eject support plate Install this plate when scanning ...
... About DR-5020/5080C N Removable tray This tray can be installed on the document eject tray to prevent short-length documents from flying out of the tray when they are provided: a label describing which function is registered to the function key and a label for fixing on the document eject... tray and curling. N Function key labels Two labels are ejected from becoming caught on the document tray as the document guide. This plate prevents such documents from the scanner. N Document eject support plate Install this plate when scanning ...
Instruction Manual
Page 23
Chapter 2 Preparation Before Use System Requirements To use the DR-5020/5080C, you need the following items in addition to the standard accessories: G Computer G SCSI card G SCSI cable G Application MEMO • The driver may not function properly depending on the application you are using. • Select a computer, operating environment and SCSI card to suit the application you are using. 22
Chapter 2 Preparation Before Use System Requirements To use the DR-5020/5080C, you need the following items in addition to the standard accessories: G Computer G SCSI card G SCSI cable G Application MEMO • The driver may not function properly depending on the application you are using. • Select a computer, operating environment and SCSI card to suit the application you are using. 22
Instruction Manual
Page 24
...Connection This section describes scanner installation and connection. The scanner weights approximately 20 kg (44.2 lb). WARNING Before you move the DR-5020/5080C, hold it , nip your fingers and cause unexpected injuries. Also, disconnect the SCSI cable from the power outlet. Moving the scanner with both hands ...power still ON or the SCSI cable still connected might result in the Safety Precautions (P.8). For details on the scanner installation location, see "About the Installation Location" in electrical shock. 23 If you carry it without holding its handles, you move ...
...Connection This section describes scanner installation and connection. The scanner weights approximately 20 kg (44.2 lb). WARNING Before you move the DR-5020/5080C, hold it , nip your fingers and cause unexpected injuries. Also, disconnect the SCSI cable from the power outlet. Moving the scanner with both hands ...power still ON or the SCSI cable still connected might result in the Safety Precautions (P.8). For details on the scanner installation location, see "About the Installation Location" in electrical shock. 23 If you carry it without holding its handles, you move ...
Instruction Manual
Page 37
... sure that the ink or paste on the pages is fed through the scanner or graphite from the surface of the document may transfer to scan these guidelines when you scan a slippery surface document, friction may be legible on a copier and the scan the copy. If this ... in the Duplex mode, ink printed on one side may cause a feed error to documents and scanner malfunction, do not feed the following types of document sizes. If the documents are scanned with binding holes 36 Chapter 3 Preparing Documents About Documents The DR-5020/5080C can feed a wide variety of paper into the...
... sure that the ink or paste on the pages is fed through the scanner or graphite from the surface of the document may transfer to scan these guidelines when you scan a slippery surface document, friction may be legible on a copier and the scan the copy. If this ... in the Duplex mode, ink printed on one side may cause a feed error to documents and scanner malfunction, do not feed the following types of document sizes. If the documents are scanned with binding holes 36 Chapter 3 Preparing Documents About Documents The DR-5020/5080C can feed a wide variety of paper into the...
Instruction Manual
Page 57
...mode for scanning and storing text. For Photo mode Tells the scanner to scan and store only the front side of the page. This sheet is ignored if it together with the DR-5020/5080C. Insert this Function Sheet before the text document, and load it is set to Black and White. Insert this... Function Sheet before the document to be scanned, and load it together with Scan Mode set to Grayscale...
...mode for scanning and storing text. For Photo mode Tells the scanner to scan and store only the front side of the page. This sheet is ignored if it together with the DR-5020/5080C. Insert this Function Sheet before the text document, and load it is set to Black and White. Insert this... Function Sheet before the document to be scanned, and load it together with Scan Mode set to Grayscale...
Instruction Manual
Page 65
...code in upper case. U5-1 Sound buzzer during key operation. (default) Document detection setting U2-0 Detect document width by paper guide width. (default) U3-0 U3-1 U3-2 Do not detect document skew. (default) Detect document skew and stop scanning. (excluding manual mode) SCSI synchronization setting U4-0... Transfer SCSI synchronization. (default) Bar code setting U5-0 Do not sound buzzer during key operation. Chapter 3 Preparing Documents Setting in the User Mode The DR-5020/5080C allows you to select which operation mode (user mode) is used for each of the items below. (Settings ...
...code in upper case. U5-1 Sound buzzer during key operation. (default) Document detection setting U2-0 Detect document width by paper guide width. (default) U3-0 U3-1 U3-2 Do not detect document skew. (default) Detect document skew and stop scanning. (excluding manual mode) SCSI synchronization setting U4-0... Transfer SCSI synchronization. (default) Bar code setting U5-0 Do not sound buzzer during key operation. Chapter 3 Preparing Documents Setting in the User Mode The DR-5020/5080C allows you to select which operation mode (user mode) is used for each of the items below. (Settings ...
Instruction Manual
Page 67
Chapter 4 Troubleshooting This chapter describes causes of trouble that may occur on the DR-5020/5080C and how to remedy the trouble. 4.1 When The Scanner Is Not Recognized 68 4.2 Removing Paper Jams 70 4.3 Paper Feed Trouble 75 4.4 When The Scanned Image is Not Normal 77 4.5 When An Error Code is Displayed ....78
Chapter 4 Troubleshooting This chapter describes causes of trouble that may occur on the DR-5020/5080C and how to remedy the trouble. 4.1 When The Scanner Is Not Recognized 68 4.2 Removing Paper Jams 70 4.3 Paper Feed Trouble 75 4.4 When The Scanned Image is Not Normal 77 4.5 When An Error Code is Displayed ....78
Instruction Manual
Page 70
... tray guide if it is open. 70 Paper scraps left inside the DR-5020/ 5080C. You may have jammed if scanning stops midway or "PXX" appears on the document eject tray. For example, the paper edges may be damaged. • Remove all jammed sheets of paper. Paper Jam in the Paper Feed Unit... 1 Remove the documents from inside the unit may be drawn into the unit again, causing another paper jam or malfunction. • When opening or closing the upper unit...
... tray guide if it is open. 70 Paper scraps left inside the DR-5020/ 5080C. You may have jammed if scanning stops midway or "PXX" appears on the document eject tray. For example, the paper edges may be damaged. • Remove all jammed sheets of paper. Paper Jam in the Paper Feed Unit... 1 Remove the documents from inside the unit may be drawn into the unit again, causing another paper jam or malfunction. • When opening or closing the upper unit...
Instruction Manual
Page 79
... error code. Two or more sheets may have been counted, and scan the document again. 79 Turn the power OFF, contact the store of purchase or a Canon service department, and notify them of an A3/11" x 17"-size document. Press the Stop key to reset the counter to "0". Press the Stop key... An Error Code is counted. Close the imprinter cover and endorser ED600 cover. Close all document sheets have been fed when the number of sheets to "0". Remedy Press the Stop key to reset the counter to see "DR-5020/ 4 5080C Scan Mode Tables." (P.88) Error code Cause Remedy L02 Too much data. ...
... error code. Two or more sheets may have been counted, and scan the document again. 79 Turn the power OFF, contact the store of purchase or a Canon service department, and notify them of an A3/11" x 17"-size document. Press the Stop key to reset the counter to "0". Press the Stop key... An Error Code is counted. Close the imprinter cover and endorser ED600 cover. Close all document sheets have been fed when the number of sheets to "0". Remedy Press the Stop key to reset the counter to see "DR-5020/ 4 5080C Scan Mode Tables." (P.88) Error code Cause Remedy L02 Too much data. ...