Sanyo mpr-214f Support Question
Find answers below for this question about Sanyo mpr-214f - Commercial Solutions Refrigerator.Need a Sanyo mpr-214f manual? We have 1 online manual for this item!
Question posted by chamathu2003 on September 14th, 2010
Remote Sensor Activated
Short circuit/E06 Displayed.
Anyway disable the alarm as we don't need such warning for our use.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Sanyo mpr-214f Manual Pages
Instruction Manual - Page 2
... SANYO if any point in Japan. CONTENTS
PRECAUTIONS FOR SAFE OPERATION CAUTIONS FOR USAGE ENVIRONMENTAL CONDITIONS REFRIGERATOR COMPONENTS INSTALLAITON START-UP OF UNIT OPERATING INSTRUCTIONS ALARMS AND SAFETY FUNCTIONS SETTING OF ALARM RESUME TIME DEFROSTING MAINTENANCE AUTOMATIC TEMPERATURE RECORDER INSTALLATION OF TEMPERATURE RECORDER TROUBLESHOOTING DISPOSAL OF UNIT SPECIFICATIONS PERFORMANCE...
Instruction Manual - Page 7
...will result in time.
• If the ambient temperature is fairly high, the alarm lamp is flashed, temperature display is flashed, and the buzzer sounds at the time of defrosting of about -2oC .... This protects the compressor.
• This inner cabinet is refrigerated by following the procedure on page 19 "Defrosting" when the freezer is not used or at the time of the port, a rubber cap and...
Instruction Manual - Page 11
... doors and left side lock is displayed on the refrigerator bottom directly. See page 19 for the left upper and lower doors. 9. Shelf (for refrigerator): Place the material on the glass... through this vent is installed inside the enclosure. Remote alarm terminal (rear): This is never blocked. Always put on this vent is used to alarm the abnormality to be frozen. 13. Remove the...
Instruction Manual - Page 12
... during alarm condition. Alarm lamp (ALARM): This lamp is accepted.
4. Refrigerator indicator (REFRIGERATOR): This indicator is lit when the refrigerator is selected.
9. See "Key lock operation" on page 15.
5. Numerical value shift key ( ): Pressing this key in the key lock mode.
6. Temperature display: This indicator shows the chamber temperature, set is activated...
Instruction Manual - Page 13
... sure to high humidity
WARNING
Do not use the unit outdoors. Never install the unit in water spillage or injury from the unit tipping over .
CAUTION
Select a level and sturdy floor for ventilation. Do not install the unit under water pipes or steam pipes.
Heat can cause inefficient refrigeration.
4. Improper installation may result...
Instruction Manual - Page 16
... change enabled Temperature change disabled
Table 2 Key lock setup procedure (Example: Key lock OFF ˰ Key lock ON)
Operation
Key operated
Indication after operation
1
Select freezer (FREEZ.)by the 6 procedure 6 through 9 in memory and
SET
the current refrigerator temperature
is displayed.
5 Check the defrosting is set to -00 by using the keys on the...
Instruction Manual - Page 17
... the chamber temperature deviates from set temperature by more than -3oC.
The current refrigerator temperature is activated when the chamber temperature deviates from set temperature by more than +3oC and low temperature alarm is displayed.
2
Press and hold the numerical value shift key for about 5 seconds.
The following shows the outline of the current...
Instruction Manual - Page 18
... the key leads the change of the temperature
display blinks.
The value is stored in memory and
SET
the current refrigerator temperature
is displayed
SET
and the first digit of the temperature
display flashes.
5
Set to 4 (F04).
17 The current set key. The current refrigerator temperature is displayed.
2
Press and hold the numerical value shift key...
Instruction Manual - Page 19
... in the
case of 0oC or lower)
Remote alarm is activated after a
minutes. turns OFF. Remote alarm is displayed.
----- minutes.
-----
If the defrost sensor goes Open (E05) or short circuit (E06). Alarm lamp flashes. Remote alarm is lit.
Table 6 Alarms and safety functions
Kind of refrigerator goes open (E03) or short circuit (E04). If the chamber temperature
exceeds the...
Instruction Manual - Page 20
... chamber temperature is installed at the factory. The buzzer and remote alarm will be set key. The suspension time can be activated again after operation
The current chamber temperature
1
-----
Pressing the key shifts up the figure
of the temperature
display flashes.
5
Set to F25 by using digit shift key 3 and numerical value shift key. is...
Instruction Manual - Page 21
... has reached to about 10oC during defrosting.
20 No temperature alarm is complete, normal operation resumes. DEFROSTING
Refrigerator The following procedure as the freezer has no automatic defrosting function... are adopted for the refrigerator, which has accumulated on the evaporator. This is melted by the defrost sensor. When the frost is displayed alternately on the freezer wall...
Instruction Manual - Page 22
... may cause electric shock or short circuit. • The compressor and other mechanical part are dirty, use a cloth containing diluted neutral ...a diluted neutral dishwashing detergent is located at the time of refrigerator chamber. (Fig. 1)
1. Disconnect the power supply plug.... a new bulb and replace the lamp cover. MAINTENANCE
WARNING
Always disconnect the power supply to the unit prior to...
Instruction Manual - Page 23
...MPR-S30
MPR-S30 MPR-S7
Access port for refrigerator
Access port for freezer
Port for taking out the recorder sensor
Recorder (MTR-0620LH) & recorder fixture (MPR-S30) or Recorder (MTR-4014LH) & recorder fixture (MPR-S30) or Recorder (MTR-G3504) & recorder fixture (MPR...G3504
For freezer For both refrigerator and freezer
Lower left of front panel (In the case of no use of MTR4014LHʣ Lower ...
Instruction Manual - Page 24
... from the edge of the refrigerator by using the 2 screws as shown in Fig. 2.
Remove the caps (both outside ) of 4 screws on the back side of
the sensor.
Attach the fixture to the...on the front left of recorder MTR-0620LH (1)
1. Fix the recorder sensor to the temperature recorder (MTR-0620LH) by using the large clips provided as shown in the port. Arrange the capillary ...
Instruction Manual - Page 26
Pass the recorder sensor to avoid the crush of the tube when bending the capillary tube.
ɾDo not bend the tube of 30 mm from the edge of the refrigerator by using the large clips enclosed with the recorder fitting (MPR-S30: optional component). (Fig. 9)
6. Then replace the thermal insulation and caps (both outside...
Instruction Manual - Page 30
... for access port to the attachment hole on the left side of the refrigerator by using the clips enclosed with the recorder fitting (MPR-S7: optional component). (Fig. 20)
Fig. 20
29 Note: Make... the back side of the freezer by using the clips enclosed with the recorder fitting (MPR-S7: optional component). (Fig. 9)
Clip
Fig. 19 7. Fix the recorder sensor to pass the lead wire as shown ...
Instruction Manual - Page 31
...use 1. When the unit does not get cold enough 1. There is too high. 6. DISPOSAL OF UNIT
WARNING
If the unit is not enough. 2. The disposal of power source is to another refrigerator or freezer before calling for an extended period ensure that children do not have access and doors cannot be accomplished by refrigerator... When alarm is in the unit. 3. The unit is activated On ...
Instruction Manual - Page 32
... side condenser (Freezer)
Refrigerant
R-134a (Refrigerator, Freezer)
Defrosting
Cycle defrost and forced defrost (Refrigerator) Natural defrost by stopping operation (Freezer)
Defrost heater
46.3 W (Refrigerator)
Temperature controller
Microprocessor control system
Temperature display
Digital display
Thermal sensor
Thermister sensor (Refrigerator, Freezer)
Alarm & Safety
High temp...
Instruction Manual - Page 34
... is some danger (see below . Date : Signature : Address, Division : Telephone :
Product name:
Model:
Serial number:
Pharmaceutical Refrigerator with Freezer
MPR-214F
Please decontaminate the unit yourself before servicing. CAUTION
Please fill in this unit.) Notes :
2. Refrigerator contents : Risk of infection: Risk of toxicity: Risk from radioactive sources:
˘Yes ˘Yes ˘Yes...
Similar Questions
How To Reset E06
How to reset E06 if we don't have a remote sensor?
How to reset E06 if we don't have a remote sensor?
(Posted by neretinyuriy 4 years ago)
What Does Error E07 Mean On Sanyo Mpr-214f?
What Does Error E07 mean on Sanyo MPR-214F?
What Does Error E07 mean on Sanyo MPR-214F?
(Posted by taniastewart 9 years ago)
What Is Mfg Accuracy On Mpr-214f?
(Posted by ThomasGollery 13 years ago)