Question posted by Weirdo23 on May 27th, 2014

Sns On Display.

When I turn on the unit it will display RV1 and the temp for a couple of seconds and then display SNS and either Pool, Spa or OFF as I press the mode button. This is with the unit set to REM OFF. If I turn the unit to REM ON by holding down all three buttons for 5-7 then it just displays SNS OFF. The guide on the unit says SNS is a sensor error, but I don't know which sensor it is refering to.

Current Answers

Answer #1: Posted by Weirdo23 on June 1st, 2014 6:07 PM
This answer was accepted by the poster of the original question.
Weirdo23

Member since:
May 27th, 2014

Points: 50
1,100
points
I was able to download the manual from this site and found out that the SNS error refers to the temp sensor. It is the RAYPACK 009577F Temperature Senor. You can get a new one from Amazon.com for about $35. It's a pretty easy repair.

Supporting Image

You can click the image below to enlarge

Related Rheem P-M406 Manual Pages

Brochure - Page 2

...compatible with no " Hard Light" to stifle ordinary pool and spa heaters. The payoff? The display uses real English, with most reliable and robust ...turn-on the end of each unit and balance out the duty load, thus avoiding over 30 years. Every piece of durable service. Underneath the tough, yet beautiful finish, you will always burn clean and safe. Multi-unit...
Brochure - Page 3

...The Rheem Digital is built to transfer heat efficiently, and is an excellent choice for pool and spa heater heat exchangers, where the water chemistry is properly maintained. When you when the need..., equipment rooms or unusual venting configurations require the use of your ability to maintain the pool or spa water chemistry, a cupro-nickel heat exchanger is well known for its policy of vent...
Operating Instructions - Page 1

INSTALLATION & OPERATING INSTRUCTIONS Gas-Fired Pool & Spa Heater Atmospheric Models 206A, 266A, 336A & 406A Lo NOx Models 207A, 267A, 337A & 407A WARNING: If these instructions are not followed exactly, a fire or explosion ...
Operating Instructions - Page 2

..., it is essential that your water. Additions: Control Lockout instructions on pages 48-55. Deletions: None 2 Recommended Level(s) Fiberglass Pools Fiberglass Spas Other Pool & Spa Types Water Temp. (Deg. F) 68 to 88 89 to 104 68 to 104 pH 7.3 to 7.4 7.3 to 7.4 7.6 to 7.8 Total Alkalinity (PPM) 120 to 150 120 to 150 80 to ...
Operating Instructions - Page 3

... 3 37 2-Wire Remote Control MAINTENANCE & CARE PROCEDURES 37 3-Wire Remote Control 8 Pool & Spa Water Chemistry 38 Time Clock / Fireman's Switch 8 Automatic Chlorinators & Chemical Feeders 38...Pressure Switch 9 Cold Weather Operation 38 Flame Roll-Out Safety Switch 9 Winterizing the Pool & Spa Heater 38 High Limits 10 PART TWO 39 Pilot Safety INSTALLATION & SERVICE INSTRUCTIONS ...
Operating Instructions - Page 4

... the use of safe and reliable pool/spa water heating. Ensure that the system is filled with millivolt or electronic ignition. It is an easy task. ASME-certified units, typically used in the Control Adjustments... and free from 65°F (18°C) to turn the heater On or Off and adjust the temperature settings for years of the controls in commercial applications, are also available.
Operating Instructions - Page 7

...WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas control to the heater, and will void the ...switch should obtain a physician's advice before using pools or hot tubs. 6. Pregnant Women Beware! CAUTION MAIN BURNER FLAME Elevated water temperature can cause fetal damage during spa or hot tub use spas or hot tubs. 7 Otherwise, rapid and ...
Operating Instructions - Page 8

... pressure will cause rapid corrosion to your gas supplier or qualified service agency. 5. POOL & SPA WATER CHEMISTRY Chemical imbalance can cause severe damage to the heat exchanger. overnight). NOTE... operate all controls, gas valve and pressure relief valve (if equipped). 4. Try re-setting it may be that are not moving water (or your water chemistry according to cleaning...
Operating Instructions - Page 9

... to avoid freeze-ups. Observe the following procedure for freeze protection. Drain Plug 3. Turn off gas valve, manual gas valve, and electrical supply to maintain water temperatures just above...(continuous pump operation) must . COLD WEATHER OPERATION WINTERIZING THE POOL & SPA HEATER IMPORTANT FREEZE INFORMATION MODERATE CLIMATE: Heater operation can seriously damage the heater, and is...
Operating Instructions - Page 10

...If there are shipped inside the bezel above the display Model & Serial No. In/Out flanges (2) 3. Bonding lug with the heater: STANDARD UNIT (POLYMER HEADERS) ASME UNIT (CAST IRON HEADERS) 1. On receipt of ... is suggested that this manual does not answer, please contact the factory or your pool/spa heater. The Model & Serial No. Plastic pipe finish flange for the equipment. ...
Operating Instructions - Page 23

.... Valve lever should be tripped at the heater. The maximum acceptable pressure relief valve setting is hot, close bypass; Install pressure relief valve hand tight plus 1/2 turn. From Heater To Heater CAST IRON HEADER PRV (ASME MODELS) To Pool/ Spa From Pool/ Spa AUXILIARY BYPASS VALVE (DO NOT USE GATE VALVE) AUXILIARY BYPASS VALVE ADJUSTMENT To...
Operating Instructions - Page 24

... pump, filter and heater are thus plumbed in order for it to the pool or spa. PLUMBING-WATER CONNECTIONS Single Pool Heater Installation Multiple Pool Heater Installation The heater requires water flow and positive pressure to maintain set-point, the heater will then display sensed water temperatures downstream of the primary heating system, rather than the...
Operating Instructions - Page 32

... the knob stop adjustment ring illustrated below the maximum level. SPA TEMPERATURE RANGE POOL TEMPERATURE RANGE 2. Do not force. CONTROL ADJUSTMENTS ADVANCED FLAME TECHNOLOGY (AFT) MODELS Temp Adjust Buttons Mode Button KNOB STOP RING SET SCREW STAND-BY TEMPERATURE KNOB STOP SHOWN ABOVE IS IN THE SPA TEMPERATURE RANGE LCD Display ON OFF 32 KNURLED SCREW The thermostat is...
Operating Instructions - Page 33

... the user to turn the heater off cycles of the heater, as measured by the number of operation for possible causes and corrections. Temp Buttons If the heater is displayed along with "No Demand." Press the DOWN button. The LCD display window indicates the mode (OFF, SPA, POOL) and the actual water temperature. FLAME STRENGTH INDICATOR Press the DOWN button. SUPPLY VOLTAGE...
Operating Instructions - Page 34

... into the program screen. Press and hold the button (5-7 seconds) until Pool Max Temp appears on the display. This operation resets the Fault History file to step one above to desired settings. 34 Spa Max Temp - Pool Max Temp - Pool Set Point Maximum Adjustment Refer to "0" and clears all the stored faults. Press the Mode button until Set Factory Defaults appears on the...
Operating Instructions - Page 35

... the 8 second trial to clear the fault. Due to the circulation characteristics of any pool or spa, the water temperature at a given location in the pool or spa. active fault conditions. Fault manded state. Ignition Lockout (Propane Tab Broken) Alternating with "No pilot sensed" - The following heat status messages are displayed in Pool, Spa and Remote modes. Display Condition...
Operating Instructions - Page 36

... will alternate even when the unit is remote-ready in the SPA Mode Remote Mode 7-PIN Remote Interface Harness Pool Common (BLK/ORN) Spa Common (ORN/BLK) 24VAC HOT (BLU) ACTIVATING THE REMOTE To activate or deactivate the remote function, follow these steps: Press and hold the UP and DOWN arrow buttons for 5 seconds before proceeding. 36 The touch...
Operating Instructions - Page 37

... Control from the heater. 5. Install the "7-Pin Remote Interface Harness" to the P8 connector and turn power "ON" to the heater. Turn the mode button to "OFF" and remove power from a remote without its own sensor, push the mode button "POOL" or "SPA" mode and set the temperature to "OFF" and remove power from a remote with a minimum of the "REMOTE...
Operating Instructions - Page 38

...: When using a time clock, the heater will display "Clock/ Fireman Sw" when the fireman's switch... of the spa or pool, it does not, repeat the above steps until proper operation is turned off immediately ..."Fireman's" switch circuit here" to the OFF mode. 3. When the heater is located on high ...FLAME ROLL-OUT SAFETY SWITCH Atmospheric heaters are set to the heater, may be used . ...
Operating Instructions - Page 46

... internal Thermostat (Unitherm Governor) and bypass valve. Atmospheric Units - Verify gas to chart below . CONTROL LOGIC - NO YES Push MODE switch to select "Pool" or "Spa" Push Temp arrow to scroll to Circuit Board (P6 connector) "Remote" and Water Temperature displayed (a remote control is in the OFF mode. OR Water temp displayed? (pilot lit and rectified) NO YES •...

Similar Questions

Rheem Pool Heater M5350ti-1
heater won't "kick on". Digital readout just shows "FLO". Adjusting the temp makes no difference. Wh...
(Posted by etarrant2871 3 years ago)
What's Wrong When There Is Alway A Message : 'low Voltage' On The Display?
What's wrong when there is alway a message : "low voltage" on the display?
(Posted by ngskus3 6 years ago)
The Display Window Is Blank.
The heater is working but I can't adjust the temps or anything else for the unit. Can I replace the ...
(Posted by Bill232323 6 years ago)
The Pilot Won't Light And After It Try's It Shows Lo On The Display,
Can u tell me what it means? 
(Posted by Jnappi 10 years ago)
Ask a New Question
Use the box below to post a new question about this Rheem product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem P-M406 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.