Question posted by cpeter5 on July 27th, 2014
Maytag Microwave Mmv4205ba Runs,no Heat,'hvt' Fuse Blows(there Are 2 Fuses)
Maytag MMV4205BA Ran, no heat and "HVT" fuse blows very quickly (there are two fuses) Replaced shorted cap w/used - within .02uf, w/ matching diode. Days later, low power; "HVT" fuse not full voltage at both ends (weird). 1 month later; ran, no heat. I removed control panel, tried for at least 5 minutes to heat a coffee, "Main" and "HVT" fuses 120v both ends. So I replaced the panel and left for work. Cooking attempts were made, lights/power/display quit. Found "Main" fuse blown. Next test, the "HVT" blew in a few seconds. I moved mw to bench and tested using an old Triplett 630-PLK type 6 w/ two batteries (one is 30v), and a Radio Shack 22-221 (analog). MAG filament; 0 ?. Filament to chassis; ? CAP; R/S - 200k to ? both ways. Triplett (x100k range) - near 0 to 9000k (both ways). DIODE; Triplett (x100k range) 85k one way, ? other. HVT Filament winding - 0 ?. Filament to chassis - ? . Secondary - R/S; 350?, Triplett; 500? (mw paper says "Approx. 90?). Primary; This has three wires at primary; blk, wh, and a blue between them. Apparently the blue's tapped in the middle for "low" power? It goes through the "HV" fuse to a relay that has the other wire white.then trips "protection" button after varying amounts of time from instantly to 10 seconds or more. I tried leaving the R/S meter attached (set to 5vdc - it's lowest range) to see if there was voltage somehow being induced and tripping the protection, and the needle did move a tiny bit. The original fuses were "BUSS MDA 20A", replacements were "BUSS ABC 20A", after running out, I'm using 20 amp glass fuses - could it be it just needs the correct "time delay", or "slow blow" fuses? Though my ohms readings are mostly "off", online info says testing the HV components is best done by replacing with "known good" parts - are there ways I can run mw with certain things disconnected to pinpoint the problem (without electrocuting myself)? I couldn't find info on the three-wire primary until I searched "inrush relay" (one of three relays shown in schematic). Could I try (for example) disconnecting the primary wires, run cook cycle, then introduce 120v to the black & white or blue & white terminals with a separate cord? Wouldn't this eliminate problems in switches, relays, etc. that occur only under load? Any ideas would be appreciated.
Current Answers
Related Maytag MMV4205BAS Manual Pages
Maytag Knowledge Base Results
We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!-
Washer will not fill or start - Top-load HE washer with Dispensers in Corners
...minutes during a cycle that the wash load is wet, there may pause for more items. Do not add more water will cause the load to see if a fuse has blown and replace...remove the inlet hoses from the water inlet valve screens. Allow the cycle to the right. To run properly, the washer should seem low because this washing machine. Do not add detergent. Use cold water. Use... -
My dishwasher will not start
...Heated Dry option (button with lock icon) for three seconds and the light should click when you reach the start of the cycle. Check your household electrical box to see if a fuse... knob to schedule service. Is there power to open or unlatched? Make sure the door is completely closed and latched. On models with a dual-digit display, the control displays "- -" during a cycle if the... -
Washer will not fill or start - Bravos washer with agitator
... Do not use short soaks (no wash action) to the washer and turned on the Cycle Control knob properly ...fuse has blown and replace it, if necessary. If the problem continues, call an electrician. Are both faucets for one second. Does the water level seem too low, or does the washer appear to be space for leaks. Plug power cord into a grounded 3 prong outlet? Is there power...
Similar Questions
Light On Control Panel Doesn't Work.
Light on control panel of microwave doesn't work. Can't read any information, including the clock th...
Light on control panel of microwave doesn't work. Can't read any information, including the clock th...
(Posted by wlkchrflly 4 years ago)
Is There A Fuse For The Display On A Maytag Microwave Mmv4205bas
(Posted by amdeligi 9 years ago)
Microwave Does Not Work But The Light Inside Comes On. Fuse?
(Posted by juliedesignmark 11 years ago)
Microwave - Mmv4205bas
microwave Mmv4205bas It is now making a humming noise & not heating and there is now a microwave...
microwave Mmv4205bas It is now making a humming noise & not heating and there is now a microwave...
(Posted by cincograhams 13 years ago)
I Have A Maytag Mmv4205bas Microwave Is There An Internal Fuse Where