Get support for LiftMaster SL575

LiftMaster SL575 Support Question

LiftMaster SL575 Support Question

Find answers below for this question about LiftMaster SL575.
Need a LiftMaster SL575 manual? We have 1 online manual for this item!
Question posted by storage1metamora on September 10th, 2012

Set Operation Hours

How to set the gate operator to not open past 10pm ?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related LiftMaster SL575 Manual Pages

SL575 Manual - Page 1

GLCONTROLLER BOARD MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial located on electrical box cover) Installation Date MODEL SL575 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
SL575 Manual - Page 2

... 1 safety instructions. 2 Operator Maintenance 23 AVERTISSEMENT Solenoid Actuated Brake 24 Friction Clutch 24 HARDWARE KIT K77-34846 Control Board Programming and Features 24-25 AVER Troubleshooting 26-27 Description Qty. Safety Installation Information 5 Suggested Entrapment Protection Device Locations 6 Safety Precautions for Open Roller Gates 7 Warning Sign Placement...
SL575 Manual - Page 3

OPERATOR DIMENSIONS AND HORSEPOWER CHART MODEL SL575 • 1/2 HP Motor Maximum Cycle Rate - 22 cycles per hour (At Maximum Gate Weight) Maximum Gate Speed - 10"/sec. (25.4 cm/sec.) Maximum Gate Weight - 1200 lbs. (544.3 kg) Maximum Cantilever Gate Width - 25 ft. (7.6 m) Maximum Overhead Roller Gate Width - 40 ft. (12.2 m) Maximum V-Track Gate Width - 30 ft. (9.1 m) • 1 HP Motor Maximum...
SL575 Manual - Page 4

... ACCESSORY SELECTION All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to operate the operator open and close . This system must satisfy...dwellings, or a garage or parking area associated therewith. CLASS IV - Non-contact sensors such as gate edges or Type D- RESTRICTED ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) ...
SL575 Manual - Page 5

... and users must be located at the bottom edge of a swing gate. b. Locate the gate such that transmits radio frequency (RF) signals to operate the controls. d. Install the gate operator only when: a. Swinging gates shall not open position. Activation of the gate. b. For a gate operator utilizing a contact sensor such as the one component. b. Additionally, if the...
SL575 Manual - Page 6

SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS GATE SYSTEM (MASTER/SECOND SLIDE GATE) Open Edge Gate 2 Open Edge STREET Photo eyes for close cycle Gate 1 Close Edge Photo eyes for open cycle Run twisted wire from loop to operator Interrupt (Safety) Loop 4'T(y1p.2icmal) 4'T(y1p.2icmal) Interrupt (Safety) Loop 6' (1.8 m) 4' (1.2 m) Typical 12' (3.7 m) COMPLEX OR PARKING LOT Seal loops...
SL575 Manual - Page 7

... using fastening holes. This operator is AVERTISSEMENT not a chance of INJURY at the leading edge, trailing edge and be averted by placing a 4' (1.2 m) screen mesh on Both Sides of the gate. SAFETY PRECAUTIONS FOR OPEN ROLLER GATES WARNING Gate Edge on Rear of Gate for Open Direction Gate Edge on Fence WARNING Post for Open Direction Gate Edge on Leading Edge...
SL575 Manual - Page 11

... the operator or gate, DO NOT drive the limit (nuts) actuators on some cantilever gates over 20' (6 m) long, you may also be required on the shaft past their normal positions. Thread the chain through the plastic chain guide, around Figure 2 drive and idler sprockets, and then through plastic guides Safety Bracket 11 Anti-Rotation Set...
SL575 Manual - Page 12

Then reverse any two of the three power leads. MODEL SL575 DISENGAGEMENT: Pull the disconnect chain and engage it necessary to Hold Cable Stop 12 The gate may be required for conduit connectors. SINGLE PHASE All single phase 115V/208/230V operators will have the following : • L1 White • L2 Black • Ground...
SL575 Manual - Page 14

... will have no effect. Activating this input when the gate is cleared, the gate continues to the open limit the Timer-to -Close. On most operators this input when the gate is closing gate to the close limit. Terminals 10 & 5 - Activating this input when the gate is closing gate to open limit. This input will reverse a closing will have...
SL575 Manual - Page 16

... the gate opening direction, to the left or to take effect, the Save Mode switch must be changed. NOTE: For any programming changes to the right. WARN MAG MAGLOCK ENABLED S2 ON ON 1 2 34 OPED CLED PH PH WARNING ENABLE This switch enables the gate "in OFF position. Right/Left operation is ON, no settings...
SL575 Manual - Page 18

... prohibited on residential garage door openers because it can be used with optional control devices for single button WARNING control to 15 rolling code remote controls or passwords in safety. ATTENTION When changing from NORMAL to the operator • Remove the brass antenna from electrocution: • Be sure power is factory set at HIGH. The...
SL575 Manual - Page 19

...8226; This control will glow steadily for changing the code setting or replacing the battery. Operation is pressed. Soft Open These terminals are now erased. Re-connect power to ...Industry Canada (IC) rules, adjustment or modifications of the gate. • Wire Stop/Reset control station to operate the gate operator. The opener will be wired within line of sight of this receiver...
SL575 Manual - Page 20

... Hard Open Override Control Input 34 56 789 N.O. Com 1 234 56 789 Interrupt (Safety) Loop Input 1 234 56 Shadow Loop Input Master or Standalone Gate Setting Master Unit ON S4 Second Gate Setting Master ...If the master detects the presence of the field wiring terminal block. The second unit will operate in the same conduit as a constant pressure override device. NOTE: Do not run Master/...
SL575 Manual - Page 22

.... Attach a wire from terminal 5 of the SL575 accessory wiring terminal block to access the SAMS system will activate its open (NO) on the auxiliary limit switch in the open times of the many gate operator types and the slide or swing gates allow the vehicle to close the barrier gate after the vehicle has passed through the...
SL575 Manual - Page 25

On most operators this will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount.... CONTROL BOARD PROGRAMMING AND FEATURES (CONTINUED) FORCE CONTROL Set the force control pot such that the unit will be around the middle of Motor Learn Routine *Hard inputs include open and close override and stop inputs. RELAY DRIVE TROUBLESHOOTING...
SL575 Manual - Page 26

... change in interference across the master/second communication line. ➤ Review program settings page 19 and check both primary and secondary power is good, check to ...gate configuration, make sure factory plug-in the same conduit with the pins on control board. If operator is in and engaging when the contactor releases. Remove the accessory and test the operator. ➤ If the open...
SL575 Manual - Page 27

... runs without slipping but will not affect the gate. The unit's manual release, when engaged, will set 2) Gate is binding or not running to terminal 6 (TB6) from terminal 6 (TB6) to the control board when the operator is not engaged. GATE EDGE PAUSES GATE WHEN STRUCK DURING OPENING GATE DOES NOT ACTIVATE TIMER TO CLOSE AFTER THE CLOSE PHOTO...
SL575 Manual - Page 34

...kit Complete with : Output shaft, sprockets, e-ring, washer, key, set screw, roll pin and spacer. model SL575-50-23, SL575-50-43, SL575-50-83 K20-3100B-4P Motor - Idler shaft kit Complete with:... kit Output shaft kit Complete with : Chain guard, chain guides and retainers. models SL575-100-23, SL575-100-43, SL575-100-83 K20-3100M-5 Motor - Spanish Owner's manual - Clutch shaft kit Complete ...
SL575 Manual - Page 36

... Overload - 15 AMP - SL575-100-11 Overload - 1.8 to 2.6 AMP SL575-100-53 (NOT SHOWN) RPM Sensor (Hall effect) ITEM K1 PART # K72-34818 DESCRIPTION Limit ...2010 25-2015 25-4002-SK K74-18379 DESCRIPTION Control board Radio - 315 MHz Limit nut Limit switch Contactor Open/close switch Transformer -115/208/230/460Vac/60VA Transformer - 575Vac/100VA Stop switch VARIABLE PARTS Overload - 6 AMP - Please...

Similar Questions

I Have Installed A Chamberlan Garage Door Opener And The Remote I Was Using Is
I have been using a Chamberlan garage door opener and its remote has been defective since of late.Pl...
(Posted by donweera42 8 months ago)
Garage Door Opens After Shutting.
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
(Posted by BONNIECA92 2 years ago)
Operation
we Have a liftmaster sl575 that was originaly set up to operate both with a remote and a three butto...
(Posted by pjokonski 9 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster SL575 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.