Get support for LiftMaster MGJ

LiftMaster MGJ Support Question

LiftMaster MGJ Support Question

Find answers below for this question about LiftMaster MGJ.
Need a LiftMaster MGJ manual? We have 5 online manuals for this item!
Question posted by dave58894 on August 8th, 2016

Need Wiring Instructions For Mj5011.

I have an 850LM receiver and a 891LM remote. Instructions say to put wire on OPEN and one on COMMON. My liftmaster only has 3 options, open,close and stop. No Common. The unit serial number is 361-A1-52649, it is about 14 years old.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related LiftMaster MGJ Manual Pages

LGJ Manual - Page 2

... OPERATOR INSTALLATIONS. REVERSING EDGE Optional) Electric or pneumatic sensing device attached to 24 feet. OPEN/CLOSE/STOP SPEED MGJ: 1050 RPM LGJ: 1725 RPM VOLTAGE MGJ: 115, 60HZ, 1Ph WIRING TYPE: MGJ: B2-C2 (Factory Shipped) LGJ: G2 (Factory Shipped) 230V, 50 or 60Hz, 3Ph 230V, 60Hz, 1Ph See pages 13 and 14 for emergency manual door operation. REQUIRED WHEN...
LGJ Manual - Page 8

... persist, call our toll-free number for close limit nut so that door will stop in open limit nut so that actuator is engaged as described below IT IS STRONGLY RECOMMENDED THAT A SENSING EDGE OR OTHER ENTRAPMENT PROTECTION DEVICE BE USED IN CONJUNCTION WITH THIS OPERATOR. Refer to spin freely. MGJ LIMIT SWITCH ADJUSTMENT MAKE SURE...
LGJ Manual - Page 11

...with optional accessories that may be used with type G2 control wiring. OPEN/CLOSE single control requiring momentary contact.. AUTOMATIC TIMER to the wiring diagram(s) indicated in close the door. Note: Refer to terminal #3. Constant pressure on close (B2 wiring) Move red jumper wire from the factory with jumper set for all control pneumatic safety (N.C.) to STOP while closing...
LGJ Manual - Page 15

... If Neccessary, Remove The Connector Block From The Board To Secure Each Wire Connection Connect field wires to keep door moving . 9 - OFF: Maximum run time is 45 seconds. WHEN CONNECTING AN CLOSE CONTROL TO: 4 - See control options below for each terminal number. 11 OR 7 9 OR OR 4 8 5 3 OPEN CLOSE STOP STANDARD 3 BUTTON CONTROL 10 5 SENSING EDGE 11 OR 9 OR 8 5 ANY...
LGJ Manual - Page 24

...door closes. 11 12 13 14 Auxiliary Terminal Block Remove Jumper When Interlock is not used, a jumper must be placed between termianls 3 and 4. pullswitch, single button, loop detector, card key or such device. 3 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 1234 2 OR MORE 1234 KEY LOCKOUT 1234 Open Close Stop Open Close Stop Open Close Stop...
MGJ S-SERIES Manual - Page 3

REVERSING EDGE Optional) Electric A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. SAFETY DISCONNECT Floor level disconnect for emergency manual door operation. MGJ WEIGHTS AND ...SPROCKET: ..........Size #41 DOOR SPEED: .........1Ph, 23RPM 3Ph, 39RPM BEARINGS: Heavy duty wormgear-in-oil-bath speed reducer. OPEN/CLOSE/STOP WIRING TYPE B2-C2 (Factory ...
MGJ S-SERIES Manual - Page 7

... with Limit Switch Adjustments before making any sensing edge wiring connections to spin freely. ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) ELECTRIC SENSING EDGES Electric sensing edges with an isolated normally open (N.O.) output are compatible with your door does not have a bottom sensing edge and you wish to the instructions provided with the edge. If your operator. Refer...
MGJ S-SERIES Manual - Page 9

... instructions, refer to the wiring diagram(s) indicated in this manual will require only momentary contact to close the door. The operator will require constant pressure on close control in order to the replacement wiring diagram for C2 wiring, which requires constant pressure on close the door. Generally a three button station (OPEN/CLOSE/STOP) is desired (B2 wiring...
MGJ S-SERIES Manual - Page 16

... TO REVERSE OR STOP 20 21 Open Open Open Sensing Device Close ALL CONTROL WIRING TYPES Close Close ALL CONTROL WIRING TYPES ALL CONTROL WIRING TYPES EXTERNAL INTERLOCK (THREE PHASE ONLY) Remove Jumper When Interlock is not used, a jumper must be connected for operation. 2) If a STOP button is Used INTERCONNECTIONS SS90 FIRE DOOR CONTROLLER SS90 FIRE CONTROL TERMINAL BLOCK MGJ "SS90...
MGJ User's Guide Manual - Page 4

... J2 L5 ^^^^ R27 TTC 1 C18 D14 LEARN STOP CLOSE OPEN LED 2 3 4 5 6 7 K2 LT C29 R24 P1 D9 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN TTC LEARN STOP CLO LEDD14 1 2 3 4 5 LMEP1 LMEP2 COM INTRLK STOP CL CLEAR THE TIMER TO CLOSE (TTC) 1. BASIC PROGRAMMING REMOTE CONTROLS SINGLE BUTTON REMOTE CONTROL Built in 315 MHz radio receiver permits as many as 20 Security✚...
MGJ User's Guide Manual - Page 8

... us online at www.liftmaster.com CONDITION POSSIBLE CAUSE OPERATOR WILL NOT RESPOND TO ANY COMMANDS No power Accessory failure Possible component failure OPERATOR MAKES Operator requires adjustment NOISE BUT DOOR DOES NOT MOVE DOOR DRIFTS AFTER OPERATOR STOPS Operator or door requires adjustment DOOR OPENS/CLOSES Operator requires adjustment TOO FAR DOOR REVERSES UNEXPECTEDLY Safety...
MGJ Manual - Page 1

OWNER'S MANUAL MODELS MGH & MGJ MEDIUM DUTY DOOR OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type www.liftmaster.com NOT FOR RESIDENTIAL USE 41B6
MGJ Manual - Page 4

... MGH: 1Ph, 23RPM BEARINGS Heavy duty wormgear-in-oilbath speed reducer. OPEN/CLOSE/STOP WIRING TYPE MGH/MGJ: C2 (factory default), B2 optional LIMIT ADJUST Linear driven, fully adjustable screw type cams. Adjustable to the bottom edge of opening and closing per second, typical, depending on door. MAX. ELECTRICAL TRANSFORMER 24VAC CONTROL STATION NEMA 1 three button station...
MGJ Manual - Page 8

... AVERTISSEMENT ATTENTION Chain Keeper (with pad locking provisions) ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) SENSING EDGES All types of sensing edges with an isolated normally open (N.O.) output are recommended for manual operation of the chain keeper mounted on the door according to the instructions provided with the edge. If not pre-installed by slipping the end...
MGJ Manual - Page 11

... all connections. Generally a 3-button station (OPEN/CLOSE/STOP) is desired (B2 wiring) you install an optional reversing edge BEFORE proceeding with some type of control station. Mount control station(s) within line of sight of adequate capacity. • ALL electrical connections MUST be on terminal #2 in the close the door. NG C O N T R O L W I R IWNAG R&NIINNGS T A L L A T I Ó...
MGJ Manual - Page 24

... ONLY SENSING DEVICE TO REVERSE OR STOP 3 10 Open Open Open Close ALL CONTROL WIRING TYPES Close Close ALL CONTROL WIRING TYPES EXTERNAL INTERLOCK (THREE PHASE ONLY) Sensing Device ALL CONTROL WIRING TYPES RESIDENTIAL RADIO CONTROLS Remove Jumper When Interlock is added to ensure proper installation and operation with the Commercial Door Operator. 4. If a STOP button is not used...
Installation Manual - Page 25

... is not programmed ➤ See PROGRAMMING REMOTE CONTROLS section. OPERATOR MOVES IN THE WRONG DIRECTION DOOR DRIFTS AFTER OPERATOR STOPS C) Door operation problem OPEN and CLOSE button wiring connection reversed A) Door not balanced properly ➤ Disconnect trolley and check door for proper operation. ➤ Check 3-button control wiring. ➤ Disconnect trolley assembly and check...
Installation Manual - Page 26

... to be determined by counting the number of flashes of the operator can travel. failure 2) Issue with Monitored Sensing Edge and/or wiring. Brake (Optional) Blue* White* * If brake is applied or cycled to the operator. (Not a logic board failure.) RESTRICTED CLOSE This method will need to fully close the door when LMEP device(s) are capped separately...
Installation Manual - Page 27

... needs. ACCESSORIES REMOTE CONTROLS 315 MHZ ENTRAPMENT PROTECTION DEVICES LiftMaster offers a variety of SECURITY✚® Remote Controls for your authorized dealer. 371LM 1-Button SECURITY✚® Remote Control: Includes visor clip. 373LM 3-Button SECURITY✚® Remote Control: Includes visor clip. 333LM 3-Button Tri-Colored Dip Switch Remote Control: Open/Close/Stop...
Installation Manual - Page 28

...All Wiring Types 01-34213F © 2011, The Chamberlain Group, Inc. EXTERNAL INTERLOCK Remove Factory Installed Jumper When Interlock is added to ensure proper installation and operation with the Commercial Door Operator. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 2 OR MORE KEY LOCKOUT 7635 7635 7635 Open Close Stop Open Close Stop...

Similar Questions

I Have Installed A Chamberlan Garage Door Opener And The Remote I Was Using Is
I have been using a Chamberlan garage door opener and its remote has been defective since of late.Pl...
(Posted by donweera42 8 months ago)
Want To Add A Transmitter And Receiver To A Lift Master Mj5011
what transmitter and receiver will work on a lift-master MJ501
(Posted by davidmarek84 3 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster MGJ manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.