Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by Etbburl on August 16th, 2014

Hayward Ecostar Cannot Get Into Timer Menu

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter to adjust, > go to enter Use + / -
EcoStar Manual - Page 19

Off --- Timer Menu Press > to set timeclocks. for no Use Timers Menu to enter Timer 1 1725rpm --- speed > Timer 1 1725rpm +/- Off --- adjust; Reset all parameters + for yes; > to change; times > Timer 1 1725rpm --- Press + to skip Are you sure? + for yes; - rename; Press > next timer T1: Timer 1 +/-
Technical Guide - Page 4

Existing Pools: When installing the EcoStar on a new pool, care should be taken to ensure proper pipe and equipment sizing to handle the ... elbow or fitting should be at least 5 times pipe size. Installation - Plumbing New Pools: When installing the EcoStar on existing pools, care should be taken to equipment manuals for flow rates. 3" 184gpm 8fps 138gpm 6fps Figure 1 Page 2...
Technical Guide - Page 7

Ground Wire Terminal. Make sure the unit is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the ...size would be connected first. One for high voltage and the other for Canada). Note: When connecting high voltage for an EcoStar that is both bonded and grounded Page 5 Bonding Lug 8 AWG (6 AWG for the low voltage data cable. Figure ...
Technical Guide - Page 8

Reposition interface assembly as shown (fig 8). 3. Remove the interface assembly as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7). Remove the two screws as shown (fig 7). 2. Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6 Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1.
Technical Guide - Page 9

... the drive to the interface assembly. Maximum 500‟ for data cable used for connecting to the interface (fig 12). 3. Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Figure 12 Figure 13 Figure 14 Page 7 Installation-Interface...
Technical Guide - Page 12

... on the controller, 8 on the pump to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to come directly from the main or sub- Wire colors can be... pump relay. panel and not from the controller (fig 22). Maximum 500‟ for an EcoStar that is not needed in the case of an OnCommand, directly from a breaker in the control...
Technical Guide - Page 24

... control v4.20 or less will only recognize address 1 (Pool Filter) and address 2 (Aux 1/ Spa Filter). For EcoStar interface software v2.55 data linked to a Goldline/Hayward compatible software control pressing & buttons will allow for the control of up to 8 EcoStars assignable to continue. 14. Only the Menu, and Stop/Resume button is active on the...
Technical Guide - Page 25

...; F. In this feature will be adjusted between 35.6 and 50º F. Press the button to continue. 16. Default is enabled you will turn on the EcoStar, if stopped, to set the Low Temp Speed ( fig 47). Press the button to continue. Press the button to set the Drive Temp Setting (fig...
Technical Guide - Page 26

.... Otherwise continue with this point you will be asked if you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next screen. If no, press the button to...Fig 49 Fig 50 Page 24 There will be a screen telling you to use the timers mode to the default parameters (factory settings ) (fig 49). If the Relay Control or the Stand alone...
Technical Guide - Page 27

... rpm (50%), 7 day operation from 12 am to 11:45 pm (fig 52). Programming-Timers Stand alone/Hayward Stand alone: Both times and speeds need to be set as needed. . Press the button until you see the Timers Menu (fig 51). Relay Control Only requires that speed be set. Press the button to the...
Technical Guide - Page 32

...System lights will be illuminated and the trip message below will not start unless one or more timers are using is an SVRS model and there is not achieved within 15 minutes. 4. The ... If the timer setting does not match the current time the pump will be replaced. 6. If the error message does not clear, cycle off the power to restart the pump. If the EcoStar you will ...
Technical Guide - Page 35

Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump. Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 The wet end disassembly of the drive and motor area for this guide.
Technical Guide - Page 41

... Timeout in 15 min increments up to change the password by pressing the '+„ button or skip by pressing the & button. If you have a commercial EcoStar you can set . If you can enable or disable the Password Protection feature by pressing the button. At this point (fig 78) you enable this...
Technical Guide - Page 46

... connection. Check motor connections to drive (page 4) to Start. Check values in Diagnosis menu and if they are all data links and run Standalone. If error still exists remove ...no change check to a Hayward/Goldline Controller, disconnect the com ground wire between 0.5 and 1.0 ohms max. There should be between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10...
Technical Guide - Page 48

...replace the interface. It travels on the comm. Control reads "Pool bridge comm" This indicates interference on the comm. ground between the...correct, replace the drive. The breaker is connected to a GL/Hayward control. Disconnect Blue, Black, and Red motor leads (page 4)..., check the Diagnostic Menu. Page 46 EcoStar is tripping. Troubleshooting/Fault Codes Code/Fault ...
Technical Guide - Page 49

... the GL/Hayward control. Control reads "Pool bridge comm." Be sure EcoStar is connected and operating via GL/Hayward control. The EcoStar should be wired to make sure the Min and Max setting on in the control (page 5). Page 47 No error on the EcoStar comm. Check the settings in the control filter configuration menu and set...
Technical Guide - Page 50

... to operate via the GL/Hayward control. When the control is operating the EcoStar, the Speed buttons and the Quick Clean button is connected and operating via the GL/Hayward control. Try changing channel on...Fault Indications The freeze protection in the EcoStar to the comm. The Speed buttons and Quick Clean buttons on and off. Only the Stop/Resume and Menu button is wired and set to ...
Parts Diagram - Page 1

...10 1 1 1 10 10 10 1 1 10 1 10 1 1 100 1 5 1 1 5 5 1 5 Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10 11 3 78 9 13 14 ...) Motor Drive Display Cover Motor Drive Wiring Cover Digital Control Interface Assembly Wall Mount Kit HAYWARD 28 25 24 Ctn. NOT Pressure Testable) Strainer Cover O-Ring Strainer Basket Diffuser Screw ...

Similar Questions

How To Unlock The Configuration Menu On The Aquapod
I want to enable the spa timeout feature as my spa was on all night. My configuartion menu is locked...
(Posted by chrisbickel 10 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.