Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by Simro on December 30th, 2013

Hayward Ecostar How To Change Timer

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter to adjust, > go to enter Use + / -
EcoStar Manual - Page 19

for yes; - Timer Menu Press > to change; Reset all parameters + for yes; > to skip Are you sure? + for no Use Timers Menu to set timeclocks. speed > Timer 1 1725rpm +/- times > Timer 1 1725rpm --- Off --- Press > next timer T1: Timer 1 +/- Press + to enter Timer 1 1725rpm --- Off --- adjust; rename;
Technical Guide - Page 4

... SIZE 1.5" 2" 2.5" 51gpm 8fps 84gpm 8fps 120gpm 8fps 38gpm 6fps 63gpm 6fps 89gpm 6fps * Refer to handle the maximum flow required (fig 1). Existing Pools: When installing the EcoStar on a new pool, care should be taken to ensure proper pipe and equipment sizing to equipment manuals for flow rates. 3" 184gpm 8fps 138gpm 6fps Figure 1 Page 2
Technical Guide - Page 7

... Conduit Connections There are two on the pump. Make sure the unit is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in the case.../High Voltage High Voltage Wiring terminals (L1 & L2) 1. Note: When connecting high voltage for an EcoStar that is both bonded and grounded Page 5 Voltage: 230 VAC, 60Hz, Single Phase. 2. Breaker, wire...
Technical Guide - Page 8

Reposition interface assembly as shown (fig 8). 3. Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1. Remove the interface assembly as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7). Remove the two screws as shown (fig 7). 2. Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6
Technical Guide - Page 9

... Figure 14 Page 7 After removal of the interface assembly (Page 7) remove the plug connecting the drive to the interface assembly. Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Maximum 500‟ for data cable used for connecting...
Technical Guide - Page 12

... run through the second (data) conduit opening and channel (Page 8). 2. panel and not from the controller (fig 22). Installation-Hayward/Goldline Controls (Compatible software shown below) 1. Maximum 500‟ for an EcoStar that is not needed in the case of an OnCommand, directly from a breaker in the control, or in units 8 Mfg...
Technical Guide - Page 24

... software mode the timers do not need to continue. Programming-Configuration Hayward/Goldline Compatible Software Control 13. The Goldline/Hayward controller will give you 9 address choices. Press the button to a Goldline/Hayward compatible software control pressing & buttons will only recognize address 1 (Pool Filter) and address 2 (Dual Spa Filter). For EcoStar interface software v2...
Technical Guide - Page 25

... Low Temp Speed ( fig 47). This speed can be adjusted between 35.6 and 50º F. The default is 41º F. Setting will turn on the EcoStar, if stopped, to continue. Default is 1000 rpm (29%). This Temperature can be adjusted between 600 rpm (17%) and 3450 rpm (100%) by pressing the...
Technical Guide - Page 26

... telling you to use the timers mode to set or change time clock perimeters. Press the... button to continue (fig 50). 19. There will be the next to program. If yes, press and confirm on setting password protection. If no, press the button to continue. Programming-Configuration If you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar...
Technical Guide - Page 27

...Timers Stand alone/Hayward Stand alone: Both times and speeds need to be set as needed. . Note: All speed settings in Configuration. 1. This is used to continue. 2. Relay Control Only requires that speed be set to 1725 rpm (50%), 7 day operation from 12 am to the Max Settings set . Timer... 1 can be factory set . Timer 1 will be changed as relays on ...
Technical Guide - Page 32

...off the power to restart the pump. The consumption in the stand alone mode. If the timer setting does not match the current time the pump will go into the prime mode selected during ... Monday 1:30p 2500 RPM 2000 Watts Low Temp Operation 2500 RPM 2000 Watts Page 30 If the EcoStar you will begin to be displayed on the display while the pump is pressed. 3. Operation 1. ...
Technical Guide - Page 35

Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump. Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 The wet end disassembly of the drive and motor area for this guide.
Technical Guide - Page 41

...the timeout has elapsed the user will see this point (fig 78) you will be prompted to change the password by pressing the '+„ button or skip by pressing the & button. Password Protection-... this screen (fig 77) after Low Temp Operation. If you have a commercial EcoStar you can enable or disable the Password Protection feature by pressing the button. Press the button to 3 ...
Technical Guide - Page 46

...that the drive was not able to a Hayward/Goldline Controller, disconnect the com ground wire between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). If pump is ... Diagnosis menu and if they are all data links and run Standalone. Ohms reading should be no change check to Start. Pump will attempt to insure a good connection. Check motor connections to drive ...
Technical Guide - Page 48

... the data wire between the control and EcoStar. Install RS485 isolator, or new interface v2.55 rev. 1.1. When it comes on the comm. Control reads "Pool bridge comm" This indicates interference on ,... noise emitted from the control. EcoStar is connected to a GL/Hayward control. Contact Clemmons Tech Service for isolator. If still tripping breaker, replace drive.
Technical Guide - Page 49

.... No error on the EcoStar comm. Control reads "Pool bridge comm." EcoStar is connected and configured to the GL/Hayward control. Troubleshooting/Fault Codes Code/Fault Indications EcoStar is connected and operating via GL/Hayward control. The %/rpm reading does not match between GL/Hayward control and EcoStar. The pump comes on the EcoStar is configured for relay control...
Technical Guide - Page 50

... devices to operate via the GL/Hayward control. Only the Stop/Resume and Menu button is correct. If problem persists, purchase (2) model XPF 20A 3-wire noise filters through X-10 website. This is active. Try changing channel on and off. Page 48 When the control is operating the EcoStar, the Speed buttons and the...
Parts Diagram - Page 1

... Interface) Motor Drive, SVRS (Includes Digital Control Interface) Motor Drive Display Cover Motor Drive Wiring Cover Digital Control Interface Assembly Wall Mount Kit HAYWARD 28 25 24 Ctn. Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10 11 3 78 9 13 14 12 26 27 15 16...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.