Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by Anonymous-150496 on April 8th, 2015

How Do I Clear Out All The Items In The Event Log

How do I clear out all 20 of the items in the Event Log

Current Answers

Answer #1: Posted by TommyKervz on April 9th, 2015 4:17 AM
This answer was accepted by the poster of the original question.
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,793
1,100
points
  1. Start Event Viewer.
  2. In the console tree, navigate to the event log you want to clear.
  3. On the Action menu, click Clear Log


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

to adjust, > go to enter Use + / - Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter
EcoStar Manual - Page 21

SVRS inactive in water During Quick Clean Input Voltage Within Range Motor Current 1.1A (0-13.0A) Power Usage 225W (0-2650W) Driver: 78C Heatsink: 67C Comm Bus Online (Addr: 1) Event log Press + to resume normal operation. No bathers in Quick Clean mode. press STOP/RESUME again to view Pump is stopped;
Technical Guide - Page 4

... SIZE 1.5" 2" 2.5" 51gpm 8fps 84gpm 8fps 120gpm 8fps 38gpm 6fps 63gpm 6fps 89gpm 6fps * Refer to handle the maximum flow required (fig 1). Existing Pools: When installing the EcoStar on a new pool, care should be taken to insure the maximum flow does not exceed the capacity of pipe (L) between pump suction port and first elbow...
Technical Guide - Page 7

... is below high voltage wires and should be determined by the NEC and local code requirements. One for high voltage and the other for an EcoStar that is both bonded and grounded Page 5 Electrical/High Voltage High Voltage Wiring terminals (L1 & L2) 1. Ground Wire Terminal. Note: When connecting high voltage for...
Technical Guide - Page 8

Remove the interface assembly as shown (fig 7). 2. Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1. Remove the two screws as shown (fig 8). 3. Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6 Reposition interface assembly as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7).
Technical Guide - Page 9

... Figure 14 Page 7 After removal of the interface assembly (Page 7) remove the plug connecting the drive to the interface assembly. Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Maximum 500‟ for data cable used for connecting...
Technical Guide - Page 12

... (fig 22 & 23). panel and not from 4 on Remote display to 1 on the pump to 4 to the controller as they match point to operate the EcoStar Aqua Logic/Pro Logic/Aqua Plus v2.65 or higher OnCommand 1.00 or higher E-Command 4 (Original E-Command not compatible) v2.80 or higher 2 3 Figure 22...
Technical Guide - Page 24

.... Press the button to a Hayward/Goldline compatible software control v4.20 or less will be handled in the control. For EcoStar interface software v2.51 data linked to be set, as all settings will only recognize address 1 (Pool Filter) and address 2 (Aux 1/ Spa Filter). Note: In the Hayward/Goldline compatible software mode the timers...
Technical Guide - Page 25

... protection only Page 23 Press the button to continue. 16. This Temperature can be adjusted between 35.6 and 50º F. Setting will turn on the EcoStar, if stopped, to protect the drive . In this screen you will be asked to set the Drive Temp Setting (fig 48). Press the button to...
Technical Guide - Page 26

... to the default parameters (factory settings ) (fig 49). There will be asked if you would be a screen telling you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next screen. Programming-Configuration If you to use the timers mode to set or change time...
Technical Guide - Page 32

...pump is completed and 1 or more of the speed buttons or the quick clean button is pressed. 3. Clear the reason for SVRS Trip then press the Stop/Resume button to the pump a few times. Once configuration...are using is an SVRS model and there is not achieved within 15 minutes. 4. If the EcoStar you will begin to the speed selected or timed. When the Low Temp Operation is activated you ...
Technical Guide - Page 35

Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump. Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 The wet end disassembly of the drive and motor area for this guide.
Technical Guide - Page 41

... Timeout in 15 min increments up to change the password by pressing the '+„ button or skip by pressing the & button. If you have a commercial EcoStar you will see this point you will be prompted to 3 hrs by pressing the & button.
Technical Guide - Page 43

...;>‟ button to View By pressing the + button you will see the last 20 error and or trip conditions, as well as the amount of time that can be used during troubleshooting. Reads offline when not connected Event Log Press + to view information. This menu provides important information about the performance of com...
Technical Guide - Page 46

... connection between interface and drive. Check values in Diagnosis menu and if they are outside limits, replace motor. Ohms reading should be between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). Page 44 Indications Indicates that the drive was not able to start the motor. Pump will attempt...
Technical Guide - Page 48

... the interface. Page 46 If the values are correct, replace the drive. Control reads "Pool bridge comm" This indicates interference on , the pump will ramp up and down in speed... been eliminated, check the Diagnostic Menu. This is tripping. Disconnect the wires from the control. EcoStar is connected to a GL/Hayward control. If still tripping breaker, replace drive. Disconnect Blue, ...
Technical Guide - Page 49

...Pool bridge comm." wires between the pump interface and the control Check to make sure the Min and Max setting on the EcoStar comm. bus connection and NOT the input connections for Standalone/Hayward. . EcoStar.../Fault Codes Code/Fault Indications EcoStar is connected and configured to operate with the settings in the control (page 20) EcoStar reverts to Standalone mode even when...
Technical Guide - Page 50

...The freeze protection is correct. Troubleshooting/Fault Codes Code/Fault Indications The freeze protection in the EcoStar to the comm. Only the Stop/Resume and Menu button is inactive. If problem persists.... Remove wires and connect to the input terminals for protection of the EcoStar drive. Page 48 Try changing channel on and off. This indicates that the comm. wires ...
Parts Diagram - Page 1

Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10 11 3 78 9 13 14 12 26 27 15 16 17 23 2 1 19 21 16 18 22 20 Ref. NOT Pressure Testable) Strainer Cover O-Ring Strainer Basket ...1 10 1 1 1 10 10 10 1 1 10 1 10 1 1 100 1 5 1 1 5 5 1 5 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 -

Similar Questions

Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls