Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by hukeppel on January 23rd, 2014

Is Booster Pump Needed With Hayward Ecostar

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
Technical Guide - Page 1

Variable Speed Pump and Drive Technical Guide © 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.55 residential Interface FW 1.00 commercial
Technical Guide - Page 4

... 6fps * Refer to handle the maximum flow required (fig 1). Existing Pools: When installing the EcoStar on a new pool, care should be taken to ensure proper pipe and equipment sizing to ... - Plumbing New Pools: When installing the EcoStar on existing pools, care should be taken to insure the maximum flow does not exceed the capacity of pipe (L) between pump suction port and first...
Technical Guide - Page 7

... for high voltage and the other for an EcoStar that is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in the case of an OnCommand, directly from the main or sub-panel and not from the filter pump relay. It is both bonded and grounded...
Technical Guide - Page 12

... they match point to come directly from the main or sub- Reinstall plugs. Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to point. panel and not from the controller (fig 22). Maximum 500‟ for an...
Technical Guide - Page 13

Installation-Relay Connected Controls (Non Hayward/Goldline compatible software & third party controls) 1. The "Load Out" side will feed the incoming high voltage for maximum voltage in the control box. Pump power (230 VAC) needs to be rated for the pump (fig 24). Filter Pump Replay AUX Relay AUX Relay AUX Relay Fig 24 Page 11 Cable...
Technical Guide - Page 14

... as shown (fig 25). Installation-Relay Connected Controls (Non Hayward/Goldline compatible software & third party controls) 2. 1, 3 and 5 from the pump terminal needs to be wired to be wired to the 3. One side of the 24 VAC connection on the pump terminal needs to the Load side of the relays in series as shown (fig wired...
Technical Guide - Page 15

... Off On On Timer 7 Speed On On Off On Timer 8 Speed On On On On Fig 26 Filter pump relay plus 1 aux relay allows control of off and on, timer speeds can be controlled. Installation-Relay Connected Controls (Non Hayward/Goldline compatible software & third party controls) 5. By using a sequence of 2 speeds Filter...
Technical Guide - Page 16

... the emergency switch (fig 29). Some switches have wiring for its internal wiring. Installation-Remote Stop Switch 1. One side of the 24 VAC on the pump terminal need to be wired to 8 on the pump terminal needs to be wired to the e-switch for both NO and NC (normally Closed).
Technical Guide - Page 24

... data linked to individual relays/Auxiliaries (fig 45). Note: In the Hayward/Goldline compatible software mode the timers do not need to a Hayward/Goldline compatible software control v4.20 or less will only recognize address 1 (Pool Filter) and address 2 (Aux 1/ Spa Filter). For EcoStar interface software v2.55 data linked to be set, as all settings...
Technical Guide - Page 27

...pumps. This is used to run the pump if the data link fails on controller will be set in the timer menu are limited to continue. 2. Relay Control Only requires that speed be set as needed.... Timer 1 can be set. Fig 51 Fig 52 Page 25 Programming-Timers Stand alone/Hayward Stand alone: Both times and speeds need to be factory set to 1725 rpm (50%), 7 day operation from 12 am to...
Technical Guide - Page 32

... in the stand alone mode. If the EcoStar you will show on the interface. If the error message does not clear, cycle off the power to restart the pump. Auto Prime and the 3 minute prime only...on the display while the pump is a trip, both the Stop/Resume and Check System lights will be replaced. 6. If this does not clear the message the drive may need to operate as long as...
Technical Guide - Page 34

... the higher the priority. Goes back to timer 8 speed at the low speed setting. 6 am pump kicks into speed needed for solar operation. Page 32 Timer 2: At 1 pm pump kicks into the speed needed for cleaner to meet spa jet or any water feature requirement. Programming Scenarios Below is one possible Stand Alone scenario. Speed...
Technical Guide - Page 35

The wet end disassembly of the drive and motor area for this guide. Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump. Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33
Technical Guide - Page 43

... Usage 225W (0-2650W) Figure 83 Power usage range shown in ( ) Driver: 78C Heatsink: 67C Com Bus Online (addr: 1) Temperature of com link between VSC and Hayward control. Diagnostics 1. Serial Number 03045433 Drive Rev: 2.2 Display Rev: 1.16 Product Version SP3400VSP Input Voltage Within Range Motor Current 1.1A (0-13.0A) Displays firmware of...
Technical Guide - Page 46

... Ohms reading should be no change check to be between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). Check to insure other data wires are outside limits..., replace motor. There should be sure motor shaft turns freely. Pump will attempt to lead. If pump is...
Technical Guide - Page 48

... is connected to a GL/Hayward control. Control reads "Pool bridge comm" This indicates interference on , the pump will ramp up and down in speed. It travels on the comm. If not, replace motor. Troubleshooting/Fault Codes Code/Fault Indications Warning NO Comm Inspect the data wire between the control and EcoStar. Disconnect Blue, Black...
Technical Guide - Page 49

... to not interfere with a GL/Hayward control. Page 47 Control reads "Pool bridge comm." The EcoStar should be wired to a dedicated 15 amp double pole breaker. No connections are on the EcoStar is set to variable speed . The %/rpm reading does not match between GL/Hayward control and EcoStar. The pump comes on control display. wires between...
Technical Guide - Page 50

... wired and set to protect any plumbing or other devices to the pump, the EcoStar interface reads "Remote Stop Engaged". wires from freezing temperatures. (page 23) My EcoStar is connected and operating via the GL/Hayward control. Page 48 The freeze protection is active. Remove wires and connect to the input terminals for protection...
Parts Diagram - Page 1

... Kit (Includes Union Nut, Union Connector, Union Gasket - 2 ea.) Union Gasket Pump Strainer Housing, 2" x 2 1/2" with O-Ring Bracket, Motor Support Riser Base Adapter...Assembly Wall Mount Kit HAYWARD 28 25 24 Ctn. Qty. 1 1 1 10 10 10 15 1 10 1 1 1 10 10 10 1 1 10 1 10 1 1 100 1 5 1 1 5 5 1 5 Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, ...

Similar Questions

Hayward Booster Pump Model 5060
Does model 6060 replace 5060?
(Posted by davidclaporte 2 years ago)
How Do You Connect A Polaris Into A Hayward Ecostar Pump?
I replaced a old pool pump with a hayward ecostar pump and now need to reinstall my polaris booster ...
(Posted by gayethompson 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.