Question posted by Anonymous-138466 on June 18th, 2014

How Do You Open The Inner Door

The person who posted this question about this GE product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by TechSupport101 on June 18th, 2014 11:59 PM
This answer was accepted by the poster of the original question.
TechSupport101

Member since:
May 24th, 2013

Points: 12,171,305
1,100
points
Hi. Refer to the Use and Care Manual here http://www.helpowl.com/manuals/GE/GG50T06PVK/96521 for the best walk through.

Related GE GG50T06PVK Manual Pages

Use and Care Manual - Page 5

... and vice versa. ● No attempt should ever be able to detect leaks in gas applications. ! A natural gas water heater will collect first in your family and pets leave also. ● Leave the doors open for ventilation and contact the gas supplier, a qualified service agency or the fire department. ● Stay away from the...
Use and Care Manual - Page 7

... not restrict air flow to be carried some distance from either the American Gas Association, 400 N. The open flame of the water heater which give off flammable vapors are to the combustion air inlet openings (perforation openings) located around the perimeter of the structure. When such areas cannot be avoided it is recommended that a suitable...
Use and Care Manual - Page 8

... containing halogenated hydrocarbons may be used in an unconfined space within that will shorten the life of the openings. Operating Instructions Installation Instructions Safety Instructions Installing the water heater. The minimum net free area of each opening must be less than one square inch per 1000 Btuh of the total input rating of conventional...
Use and Care Manual - Page 9

...Jacket door Flammable Vapor Sensor Auxiliary catch pan Drain Pan Pipe to install an expansion tank in the inlet water line. It may have been installed in that the water heater may... trap 6" minimum To cold water supply Shut-off valve in the pressure within the water system. In an "open" water system, expanding water which exceeds the capacity of the water heater flows back into the main ...
Use and Care Manual - Page 10

... discharge line must be no smaller than the outlet of the valve and must be of the water heater as marked on its rating plate. A steady flow of relief valves. This condition is closed, then open drain to the Technical Service Bulletins 1400 Series Section and choose Bulletin #1402. Condensation Condensation can produce...
Use and Care Manual - Page 11

... lower than the value listed on male threads only. Care and Cleaning WARNING: Never use an open flame to test for LP gas. The National Fuel Gas Code (NFGC) mandates a manual gas...damaged. Turn on sea level operation. Troubleshooting Tips Pressure Testing the Gas Supply System The water heater and its gas connections must not exceed 10.5" w.c. If flexible connectors are present, ...
Use and Care Manual - Page 14

...on the following minimum clearances and considerations (see illustration): Twelve (12) inches above grade level and above any door, window, soffit, under eaves If soffit vent is too close to help prevent moisture from an inside corner formed...edge of vent terminal. Operating Instructions Installation Instructions Safety Instructions Installing the water heater.
Use and Care Manual - Page 15

...the rest of vent pipe. 15 Customer Service Four (4) feet from any opening around the vent pipe or fittings with building interior access (i.e., vent, ... Min. 12" Above Roof Min. 12" Above Anticipated Snow Level. Vent pipe must conform to the water heater's vent connector fitting on the blower outlet. Complete the vent pipe installation to American National Standards Institute and...
Use and Care Manual - Page 16

... minutes before applying cement. Provide adequate ventilation and do not assemble near heat source or open flame. Apply a liberal coat of primer to inside surface of socket and outside of cement...and socket for the motion until enough time has passed to allow primer to the water heater vent connection. In order to prevent condensate from the primer and cement to American ...
Use and Care Manual - Page 18

... manufacturer's instructions included with the safe operation of the water heater or the area where the combustion air inlet openings and Flammable Vapor Sensor are not necessary. This will interfere with the kit must be carefully followed. Do not cover the burner access door, jacket door, gas control (thermostat)/gas valve or pressure and temperature...
Use and Care Manual - Page 19

... the Blower Assembly Dilution Air holes. ❑ DON'T remove the Burner Access Door unless absolutely necessary. DON'T ❑ DON'T block or restrict Combustion Air Inlet Openings or the Flammable Vapor Sensor located around the lower portion of this water heater where standing water may require an additional 90° 3/4" NPT elbow or a 3/4" coupling depending on...
Use and Care Manual - Page 20

...(s) at least 6" from combustible material. ❑ Vapors from water damage. ❑ Sufficient room to service heater. ❑ Combustible materials, such as clothing, cleaning materials, rags, etc. Water Heater Location ❑ Close to open drain. ❑ Discharge line protected from combustion air inlet openings observed ❑ Flammable vapor sensor is not blocked. Relief Valve...
Use and Care Manual - Page 21

... present and will be suitable for use with water heater) Heating unit Care and Cleaning Troubleshooting Tips Customer Service Combustion Air Inlet Openings 6" air gap 21 This ensures that have previously been used in the installation of this water heater in the water lines will contaminate the drinking water supply causing possible health risks. DANGER: If this...
Use and Care Manual - Page 23

... be opened for a long period of time (generally two weeks or more details.) The chart below may require a 120°F or lower gas control (thermostat) setting to the "OFF" position and turn on the water heater near the gas control thermostat. Operating Procedure This heater is recommended that the outer door be removed (leave inner door in...
Use and Care Manual - Page 25

... it is turned off device that vent pipe supports are secure and that shuts the operation of the water heater, to an open drain. Rapid closing of the water heater. Strategically located risers in the water pipe system or water hammer arresting devices can be due to thermal expansion in gas appliance repair. lever handle on how...
Use and Care Manual - Page 26

... the water heater. DO NOT expose to correct the problem and clean the flue, or replace the flue, flue baffle, and venting system before resuming operation of the burner must be cleaned by its hanger at the blower assembly relief opening after inspection of gas piping and leak testing.. If the burner access door...
Use and Care Manual - Page 28

... by a qualified service technician. Refer repairs to call for the first time. Review the charts on top of combustion condensing on water heater jacket. Moisture from flue or combustion air inlet openings on the tank surface. Remove obstruction or debris from the products of the burner. Gas Cock Knob not correctly positioned. See...
Use and Care Manual - Page 29

... build up caused by thermal expansion to recover after an abnormal demand. The pilot burner may be corrected. Leaking or open hot water faucets. Wait for the water heater to a closed . Verify power supply (120VAC). Water usage may be set too high. Blower unplugged. Pilot Burner Lights, but Combustion Shutoff System Main Burner will not...
Use and Care Manual - Page 30

... Lockout condition. Contact qualified service technician. ● Make sure manual gas shutoff valve is open. ● If pressure is "OFF" before removing protective cover FOR ANY REASON. Lockout ...condition. ● Contact local qualified service technician. CAUTION: Label all wires prior to water heater is too high, the valve will not operate. Standby Mode. Unplug to page ...
Use and Care Manual - Page 31

.... CAUTION: For your safety, DO NOT attempt repair of the water heater from the rating plate. Drain valve Gas Control (Thermostat) Care and Cleaning Troubleshooting Tips Customer Service *Burner Flammable Vapor Sensor *Burner Access Door Gasket *Burner orifice *Spark Igniter Assembly *Burner Access Door *Pilot supply tube *Burner supply tube *Spark Igniter Wire *Sight...

Similar Questions

Water Heater Is Out
The gas is good to the water heater bu it will not start.
(Posted by dglover 8 years ago)
My Water Heater Keeps Going Into System Lockout /
water heater will work fine for a day or two then will go into system lockout , then work fine for a...
(Posted by rmjozwiak 8 years ago)
Do You Have A Manual For A Ge Hot Water Heater Model #pg40t09avh00?
We are having trouble finding how the ignitor switch hooks up and works. the MFG# is 4/2009. Serial ...
(Posted by mallissaworley 12 years ago)
Gg50t06pvk Ge Power Vent Water Heater
The ignitor on my unit turns on and gets hot but burner does not fire. Error code shows green light ...
(Posted by mjobrien911 12 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE GG50T06PVK manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.