Get support for GE 60-806-95R-16Z - Security Concord Express System Control Panel

GE 60-806-95R-16Z Support Question

GE 60-806-95R-16Z Support Question

Find answers below for this question about GE 60-806-95R-16Z - Security Concord Express System Control Panel.
Need a GE 60-806-95R-16Z manual? We have 1 online manual for this item!
Question posted by DPruitt12 on August 17th, 2017

Sudden, Unexplained Beeping From Touch Pads!

Can anyone tell us how to remedy, or disable, the beeping from the touchpads on this model? Our system is old and we can't get in touch with the installer. The intermittent beeping started at 2:30 this morning and was still going strong when we left for work at 7:30. Thank you!

Current Answers

Answer #1: Posted by waelsaidani1 on August 21st, 2017 4:45 AM
This answer was accepted by the poster of the original question.
waelsaidani1

Member since:
May 12th, 2013

Points: 19,501,797
1,090
points
Changing Fixed Display LCD Touchpad Chime and Trouble Beep Tones

The frequency (pitch) of chime and trouble beep tones from a fixed display touchpad can be

adjusted to a more desirable or distinct tone, and to compensate for hearing impaired persons.

¾

To change status tone pitch:

1. Press and hold the , and 0 buttons together until you hear a steady tone, then release the

buttons.

2. Press and hold 1 to lower the pitch or press and hold 2 to raise the pitch.

3. When the desired pitch is heard, release the button.

If there is no touchpad activity for about 15 seconds, the steady tone stops sounding

Related GE 60-806-95R-16Z Manual Pages

Installation Instructions - Page 1

... w ay 3 6 M enu 9 B ypass # Concord Express Installation Instructions A rm to S T A Y 1 C lo se a ll p ro te c te d d o o rs a n d w in d o w s. 2 P ress 2 + C O D E . 3 P re ss 4 to se le c t o p tio n o r a c c e p t e n try . A rm to d e sire d le v e l. 2 P ress B Y P A S S + C O D E + S en so r N o . ) *( 6HFXULW\ ZZZ*(6HFXULW\FRP Part No: 60-806 60-806-95R 466-1665 Rev G June...
Installation Instructions - Page 5

Changing Fixed Display LCD Touchpad Chime and Trouble Beep Tones 49 Troubleshooting 50 Appendix A: System Configuration Worksheets 54 Cross-Zoning ...57 Appendix B: Programming Mode Menus and Settings 66 Specifications 68 Wiring Diagram Back Page ii
Installation Instructions - Page 6

...Control Panel (60-806, 60-806-95R) • Backup Battery, 12 VDC, 4 AH (60-681) • SuperBus 2000 2x16 LCD Touchpad (60-746-01), SuperBus 2000 Fixed Display Touchpad (60-820), SuperBus 2000 2x20 LCD Touchpad (60-803), or SuperBus 2000 2x20 VFD Touchpad (60-804) • Standard Class II 16.5 VAC, 25 VA Power Transformer; Some installations...; DISABLE TROUBLE BEEPS set to off •...
Installation Instructions - Page 7

... part no.13-046. On Disabled 30 sec. 60 sec. 1 Off Disabled On On Disabled On 15-45 sec. Shortcut ...4 hours • ALARM VERIFY set to off • DISABLE TROUBLE BEEPS set to off UL 1023 & 985 24-Hour Backup &#...+ CODE) Enabled Special Installation Requirements 2 Note UL requirements take priority over SIA requirements. • Hardwire Smoke Detector: System Sensor models 2100D, 2100TD, 2100S...
Installation Instructions - Page 9

...system control panel. Installing the system consists of factory programmed settings). Before starting the installation, plan your system layout and programming using the following guidelines: 4 ming and operation control. Zone 6 can be set up to activate other signalling devices, based on page 40 for system programming and operation. • SuperBus 2000 2x16 LCD Alphanumeric Touchpad...
Installation Instructions - Page 11

... studs. ! Feed all four mounting screws. Installing the System 6 Wire Length to provide access for levelness, insert the two lower screws, and tighten all device wires through the knockout and place the panel in contact with the cover open. To discharge any static, first touch the metal panel chassis, then stay in position against...
Installation Instructions - Page 13

...; 4Z Input/2 Output Combo SnapCard-60-756 Install the desired SnapCard onto the panel SnapCard Header and secure it in Figure . Installing the System 8 Connect all necessary input/output wiring using the installation instructions included with the SnapCard. Push SnapCard Connector Onto Panel Header Secure SnapCard with the ConcordExpress panel has not been investigated by UL...
Installation Instructions - Page 14

... Normally Open (N/O) Contacts in the Concord Express G N D +12V 3 4 A BUS B 5 6 Panel Terminals Connecting Detection Devices to Panel Zone Inputs The panel comes with panel) at the last device on the circuit. Connecting N/C and N/O Intrusion Detection Circuits Figure 9 shows the typical wiring for UL Listed systems). 9 Installing the System Connecting Intrusion Detection...
Installation Instructions - Page 17

...4 2k Ohm EOL Resistor (49-454) Locate at Last Device Model 449AT Note Install all sirens/speakers indoors, in Appendix A. Model 449AT CC OONN +. +. .- .- O. Connecting 4-Wire Smoke Detectors.... 15-Watt, Dual Tone Siren (13-469) Panel terminal 7 (OUT1/+12V) is connected. Black (Common) Yellow (Steady) GND Concord Express Panel Terminals 3 O U T1/ +12V 7 Red (Not Used) 60806G 100D D S F...
Installation Instructions - Page 22

... Touchpad 4. The touchpad sounds one short beep and the display shows a flashing star. This section describes how to the outlet box. Connect the red, black, green, and white wires from the panel header. 17 Programming the Panel After programming is completed, simply disconnect the touchpad from the Programming Touchpad Cable (60- 791) to a metal outlet cover. Note If touchpads...
Installation Instructions - Page 24

...= 8 seconds • Extended Delay = 1 minute • Siren Timeout = 2 minutes • Status Beeps = on (all touchpads) • Central Station Reporting = sensors learned into groups 01 and 03, Duress code use, and phone ... This setting determines whether the panel is used for complete details. See the section, "Programming Tier 2 Menu Items" for a standard installation (off ) or 2 (...
Installation Instructions - Page 26

...panel memory. When this setting is on OR can be annunciated. • The Arming Always Silent feature is disabled...security settings that are required by the SIA False Alarm Reduction Standard: • Arming level changes made from wireless touchpads and keychain touchpads are sounded (beeps) on exterior siren output (on) OR are still accessible by entering the program mode with the installer...
Installation Instructions - Page 27

... during occupied arming periods. Touchpads (and other status sounders) emit one exit delay beep every four seconds, then one... Delay overrides the Auto Stay Arming feature. Programming the Panel 22 Press ƒ and the display shows the new... With the display showing EXIT EXTENSION tem). Exit Extension (0013) Security-Partition 1 (Default = on ). This helps prevent exit faults...
Installation Instructions - Page 39

...(05008) Reporting-Global (Default=off) This setting works with all GE Security panels, hardwire smoke detectors connected to Concord or SnapCard hardwire zones do not send restorals. ¾ To turn...or 2 (on). ting. TP Panic RPT FMT (05009) This setting determines how the panel formats touchpad panic alarms reports to the central monitor- 2. The display flashes the entered setting. 2. With...
Installation Instructions - Page 52

...Arms system to STAY 3 (quick arm on) Arms system to exit sensor test. After 15 minutes the panel disarms to the section "If a Wireless Sensor Does Not Test." This restarts the 15 minutes of arming...Troubleshooting" section. 1. At an alphanumeric touchpad, enter the sensor test mode by pressing 8 + installer CODE + 3. Trip each zone/sensor one beep and displays SENSOR TEST, 15 MINUTES...
Installation Instructions - Page 53

.../zone in the open, the environment at least one beep. Verify that you are produced from these sirens. When...tell the operator that you will be tested to inform them that all wiring at the panel... don't respond, use an ITI RF Sniffer (60-401) test tool to verify that the sensor ...check that each of the touchpad and wireless panic buttons and trip at the installation site can have a ...
Installation Instructions - Page 54

...or user Sensor/Zone Numbers 1 - 24 Regular User Codes 0 - 15 used System Master Code used Installer Code used 680 Dealer Code used 697 Quick Arm used 698 Keyswitch Sensor used 699 System Armed Itself (... the keypad is in use (during or within 15 seconds of chime and trouble beep tones from a fixed display touchpad can be adjusted to a more desirable or distinct tone, and to compensate for about...
Installation Instructions - Page 58

.... Change mounting position of 4.7 to commands entered from other locations. Smoke sensor beeps once every minute. Sensor batteries are getting low. Wireless Touchpads System doesn't respond to 5.4 VDC. Verify that sensor is installed up into panel memory. Use an RF Sniffer (60-401) to verify that panel loop antenna is transmitting. Enter program mode and learn...
Installation Instructions - Page 64

...Beeps (Off) 0600 Installer... (On) 02005 Dial Abort Delay (30 seconds) 02006 Disable Trouble Beeps (Off) 0601 Downloader Code (12345) 0000 Downloader Phone ...No. (None) 0150 DTMF Dialing (On) 02004 Duress Code (None) 0016 Duress Option (Off) 0514 Edit Sensors (None) 073 Entry Delay (30 seconds) 0310 Exit Delay (60...
Installation Instructions - Page 73

...zone from panel memory. Output 1 B Output 2 B Output 3 B Output 4 A A A # *# *# *# * Configuration 01400 Configuration 00410 Configuration 00903 Configuration 01003 Unit - The factory programmed setting are NOT reset by an RF device (touchpad or keyfob). SIA False Alarm • SIA False Alarm (0003) option has been added to control access to Security Menu. Install an...

Similar Questions

Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE 60-806-95R-16Z - Security Concord Express System Control Panel manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.