Fluke 117 Support Question

Fluke 117 Support Question

Find answers below for this question about Fluke 117.
Need a Fluke 117 manual? We have 2 online manuals for this item!
Question posted by aviator3583 on November 11th, 2019

Burned Component

My 117 has a burned component and now it will no longer measure voltage, either AC or DC. I think that it is the component marked R3 on the circuit board. Can you please tell me the value of this resistor? If this resistor is burned, are there any other components that are likely to need replacing?The ohms range works ok

Current Answers

Answer #1: Posted by waelsaidani1 on November 11th, 2019 1:33 PM
This answer was accepted by the poster of the original question.
waelsaidani1

Member since:
May 12th, 2013

Points: 19,501,797
1,100
points
Please direct this question to: [email protected]

Related Fluke 117 Manual Pages

Fluke 114,115,117 Manual - Page 1

® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies.
Fluke 114,115,117 Manual - Page 3

...measurements >1 kHz, the Y symbol is displayed when the Meter measures a voltage ≥30 V or a voltage overload (OL) condition. The IEC 61010-1 2nd Edition safety standard defines four measurement categories (CAT I to make a measurement with a 6000-count display and a bar graph. Unsafe Voltage... Fluke Model 114, Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter ...
Fluke 114,115,117 Manual - Page 4

... that have the same voltage, category, and amperage ratings as marked on Meter, between terminals or between any terminal and earth ground. • Use caution with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. A "WCaution" statement identifies conditions and actions that could cause bodily harm or death. 114, 115, and 117 Users Manual Safety...
Fluke 114,115,117 Manual - Page 5

Refer to measure voltages in hazardous locations. • Use proper protective equipment, as unsorted ... authorities when working in hazardous areas. • Avoid working in circuits that could be impaired. • Check the test leads for disposal. 3 Symbols B AC (Alternating Current) F DC (Direct Current) X Hazardous voltage N Battery (Low battery when shown on the display.) I Fuse...
Fluke 114,115,117 Manual - Page 6

... 18 Meaning The Meter is a negative value. edy02f.eps Model 117 114, 115, & 117 115 & 117 114, 115, & 117 114, 115, & 117 The Meter function is set to Continuity. The Meter function is set to Diode Test Input is in the VoltAlert™ non-contact voltage detect mode. Measured input voltage ≥30 V, or voltage overload condition (OL). 114, 115...
Fluke 114,115,117 Manual - Page 7

... or present reading displayed 114, 115, & 117 H (Red LED) Voltage presence through the non-contact VoltAlert sensor 117 I LoZ The Meter is measuring voltage or capacitance with a low input impedance. 114, 115 & 117 J nµF mVµA MkΩ kHz Measurement units. 114, 115, & 117 K DC AC Direct current or alternating current 114, 115 & 117 L N Battery low warning. 114, 115...
Fluke 114,115,117 Manual - Page 8

...117 114, 115, & 117 114, 115, & 117 bAtt CAL Err EEPr Err F11 Err Error Messages Battery must be replaced before it will operate. Internal error. B Common (return) terminal for measuring voltage... measurements. Calibration required. 114, 115, and 117 Users Manual Terminals 1 V A COM 3 10 A FUSED 2 No. Description A Input terminal for measuring ac and dc current to 10 A....
Fluke 114,115,117 Manual - Page 9

... of ac voltage. 115 & 117 115 & 117 115 & 117 115 & 117 117 Note: All ac functions and Auto-V LoZ are dc-coupled. 7 Displays OL above 2.0 V. DC voltage from 0.1 to 600 mV. 114 & 117 114, 115 & 117 115 & 117 114, 115 & 117 114, 115 & 117 Ω Ohms from 0.1 A to 10 A (>10 to 5 kHz. True-rms Multimeters Rotary Switch Positions Rotary Switch Positions Switch Position Measurement...
Fluke 114,115,117 Manual - Page 10

.... • To pause MIN MAX AVG recording without erasing stored values, press f. The backlight automatically turns off . In the Display ... In the Manual Range mode, you apply a different voltage. 114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") The Meter automatically ...on . The Sleep mode is always disabled in the desired measurement function and range. • Press p to enter MIN MAX...
Fluke 114,115,117 Manual - Page 12

For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function. 114, 115, and 117 Users Manual Measuring Resistance Testing for Continuity XWWarning edy04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 edy06f.eps...
Fluke 114,115,117 Manual - Page 13

Measuring AC and DC Millivolts Millivolts AC Millivolts DC DC edy03f.eps Using Auto Volts Selection (114 & 117 only) With the function switch in the l position, the Meter measures ac plus dc millivolts. Press g to switch the Meter to ghost voltages. Measuring AC and DC Voltage Volts AC Volts DC V True-rms Multimeters Making Basic Measurements This function also sets the Meter's ...
Fluke 114,115,117 Manual - Page 14

... 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit... terminals, switch position, and range for your measurement. • Never place the probes in parallel with a circuit or component when the leads are plugged into the A (Amps) terminals. 1...
Fluke 114,115,117 Manual - Page 15

... (115 & 117 only) edy14f.eps edy05f.eps 13 Measuring Current above 10 Amps The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to a Fluke catalog or contact your current probe. Make sure the Meter has the correct function selected, AC or DC, for your local Fluke...
Fluke 114,115,117 Manual - Page 16

... only. Select progressively lower ranges using manual ranging for frequencies >1 kHz. Detecting AC Voltage Presence (117 only) VoltAlert Hot Neutral VoltAlert RANGE Lo edy09f.eps The Meter measures the frequency of a signal by counting the number of the measured signal is 0 V, 0 A for all ranges. 14 VoltAlert edy13f.eps The trigger level is >1 kHz, the bar...
Fluke 114,115,117 Manual - Page 17

... low as visual indication when voltage is detected. True-rms Multimeters Making Basic Measurements Testing Diodes (115 & 117) Good Diode Good Diode Forward Bias Single Beep Bad Diode Reverse Bias Bad Diode Open and Shorted edy07f.eps 15 There are two sensitivity settings. The "Hi" setting allows for ac voltage detection on flush mounted wall...
Fluke 114,115,117 Manual - Page 18

..., the bar graph and range annunciator indicates the underlying voltage or current up to the full-scale value of the scale. The bar graph is relative to ...range, for making peak and null adjustments. An input of segments indicates the measured value and is disabled when measuring capacitance. Testing the Fuse (115 & 117 only) Test fuse as shown below ), the major divisions on an analog...
Fluke 114,115,117 Manual - Page 20

... the terminals can affect readings. 18 Finally, insert the Meter into its holder and replace it with a damp cloth and mild detergent. 114, 115, and 117 Users Manual To open the case for fuse replacement: 1. Remove two screws from its holster. Separate the case bottom from the case top. 5. Cleaning Wipe...
Fluke 114,115,117 Manual - Page 21

... Multimeters General Specifications General Specifications Accuracy is specified for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 19 Maximum voltage between any terminal and earth ground 600 V Surge Protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2 W Fuse for A input (115 & 117 only 11 A, 1000 V FAST 17 kA Fuse (Fluke PN...
Fluke 114,115,117 Manual - Page 22

... AC Volts[1] True-rms 600.0 mV 6.000 V 60.00 V 600.0 V Resolution Accuracy ± ([% of Reading] + [Counts]) 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.5 % + 2 0.5 % + 2 DC, 45 to 500 Hz 2.0 % + 3 45 to 500 Hz 1.0 % + 3 500 Hz to 1 kHz 4.0 % + 3 500 Hz to 1 kHz 2.0 % + 3 0.001 V 0.01 V 0.1 V 1.0 % + 3 2.0 % + 3 Model 114, 115, 117 114, 115, 117 114, 117 114, 115, 117 114, 115, 117...
Fluke 117 Electrician Multimeter Datasheet - Page 1

... include: • VoltAlert™ technology for non-contact voltage detection • AutoVolt automatic ac/dc voltage selection • LoZ: helps prevent false readings due to ghost voltage • Large white LED backlight to work in poorly lit areas • True-rms for accurate measurements on non-linear loads • Measures 20 A (30 seconds momentary; 10 A continuous) •...

Similar Questions

Ohm Scale
ohms reading is wrong
(Posted by piyalr2021 1 year ago)
Fluke 87v Error Code
When i turn on my fluke 87v, the lcd display LEAD error and also beeping
(Posted by edgarcabrera723 2 years ago)
Fluke 381 Red Triangle
My fluke 381 stopped working it has new batteries but only the red triangle lights up
(Posted by tacevedo1018 3 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 117 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.