Dell PowerEdge 2950 Support Question
Find answers below for this question about Dell PowerEdge 2950.Need a Dell PowerEdge 2950 manual? We have 8 online manuals for this item!
Question posted by TheBu on October 7th, 2013
How To Clear Lcd 2950 I1912 Sel Full Error
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerEdge 2950 Manual Pages
Information Update - Page 3
... 6 Optional Internal USB Memory Key 6 Installing the Optional Internal USB Memory Key 7 Support for 8-GB Memory Modules - Safeguarding Encrypted Data 9 System Message Update 10 LCD Status Messages Update 15
Contents
3 Power 2950 II and PowerEdge 2950 III Systems 9 System Board Replacement - PowerEdge 2950 III Systems 9 Processor Upgrades - Contents
Non-Optimal Memory Configurations...
Information Update - Page 9
... the latest processor upgrade options for 8-GB Memory Modules - Support for your system. PowerEdge 2950 III Systems
PowerEdge 2950 III systems have added support for the following approved 8-GB memory configurations: •64... physical memory. Information Update
9 Safeguarding Encrypted Data
On PowerEdge 2950 III systems using Windows Server® 2008, you can use encryption programs, such ...
Information Update - Page 15
... occur on the PowerEdge 2950 III system and the probable cause for each message. This message is unable to determine the CPU(s) temperature status.
If the problem persists, see your systems management software documentation.
You can be defined by the user in the System Setup program. Turn off and active errors are displayed...
Information Update - Page 24
... output file pathname option enables you run the System Build and Update Utility, Microsoft® Windows® 2000 is supported by the PowerEdge 2950 and 2950 II systems, but not by the PowerEdge 2950 III system.
System Support for Microsoft Windows 2000
If you to a hard drive.
24
Information Update System Diagnostics Update
In the...
Information Update - Page 27
目录
29
PowerEdge 2950 III 29 29 29 全新 I/O 30 30
内部 USB 30 USB 30
支持 8 GB PowerEdge 2950 III 32
PowerEdge 2950 II 和 PowerEdge 2950 III 32
32
33
LCD 37
40 Memory 40 CPU Information (CPU 42 Integrated Devices 42 System Security 44 Serial Communication 45
目录
27
Information Update - Page 33
... Interleaving.
表 1-1 列出了 PowerEdge 2950 III
表 1-1
信息
原...22240;
纠正措施
Alert! PCIe
PCIe
SAS
No boot device available
USB CD
USB
程序"。
信息更新
33 DIMM
!!*** Error...
Information Update - Page 44
... Change TPM TPM TPM Security (TPM Off
TPM Clear
(TPM No [ 否 ])
TPM 将导致 TPM TPM 密钥。
设置为 Yes TPM TPM Security (TPM Off
44
信息更新 System Security
表 1-7 PowerEdge 2950 III TPM。
TPM Security(TPM TPM。...
Information Update - Page 46
Microsoft Windows 2000
System Build and Update Utility Microsoft® Windows® 2000 将位于 Server OS Install PowerEdge 2950 和 2950 II PowerEdge 2950 III
Customize Log output file pathname USB
46
信息更新
Information Update - Page 132
...; cat/sys/devices/system/cpu/cpuxx/cpufreq/scaling_ cur_freq
• RHEL 3 9 Intel Xeon 54xx proc/cpuinfo
RHEL 4
Microsoft Windows 2000
System Build and Update Utility Server OS Install OS OS Microsoft® Windows® 2000 PowerEdge 2950/2950 II OS PowerEdge 2950 III
Customize Log output file pathname USB
132
Information Update - Page 142
Node Interleaving disabled! DIMM
!!*** Error: Remote Access Controller initialization failure *** RAC virtual USB devices may not be available...
RAC
Invalid PCIe card found in the Internal_Storage slot! PCIe PCIe SAS
142 Memory configuration does not support Node Interleaving. 표 1-1 PowerEdge 2950 III
표 1-1
메시지
...
Information Update - Page 145
...
TPM configuration operation honored. 니다 .
DIMM 은 n1 n2
DIMM
Warning: A fatal error has caused system reset! No micro code update loaded for processor n
BIOS
145 WARNING: Modifying could....
Please check the system event log! SEL SEL
Warning!
Press I M TPM
Warning: Following faulty DIMMs are disabled:
DIMM n1 n2 Total ...
Information Update - Page 157
Microsoft Windows 2000
Microsoft® Windows® 2000 이 Server OS Install(서버 OS PowerEdge 2950 III 대신 PowerEdge 2950 및 2950 II
Customize Log output file pathname USB
157
Hardware Owner's Manual (PDF) - Page 14
... hot plug OR Four 3.5-inch hot-plug
One optional slimline IDE or DVD drive.
14
About Your System
The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text. Table 1-2. Front-Panel LED Indicators, Buttons, and Connectors (continued)
Item
Indicator, Button, or Connector...
Hardware Owner's Manual (PDF) - Page 19
...NIC Indicator Codes
Each NIC on the back panel has an indicator that provides information on the SEL and configuring system management settings, see "Getting Help" on the network. NIC Indicator Codes
...connected to boot, press the System ID button for at least five seconds until an error code appears on the LCD. See your system fails to a valid link partner on page 147. NOTE: If ...
Hardware Owner's Manual (PDF) - Page 21
...is
cleared using either Server
Assistant or the BMC Management
Utility. If the problem persists, ensure
that your processors match and conform to
the AC power source, or the SEL ...or See "Troubleshooting the
bad, and the system is reporting an internal error. Table 1-6. processor initialization error.
LCD Status Messages (continued)
Code E1410 E1414
E1418 E141C E141F E1420 E1421
Text ...
Hardware Owner's Manual (PDF) - Page 26
..." on page 120.
Intrusion
System cover has been removed. Information only.
>3 ERRs Chk Log
LCD overflow message. Check the SEL for details on page 120.
If no memory card is present, the "Crd #" string is... DIMM ##
The system BIOS has disabled See "Troubleshooting System memory single-bit error (SBE) Memory" on page 120. logging, and will not resume logging further SBEs until the system ...
Hardware Owner's Manual (PDF) - Page 27
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
I1912 SEL...27 Any of an abbreviation or acronym used in a new SEL entry.
• The system is reset and new error events are detected.
• A failure is a failing...this table, see the "Glossary" on , the LCD message is removed from the display:
• Clear the SEL - Turn off the system and disconnect it from another...
Hardware Owner's Manual (PDF) - Page 40
...latest support information about booting from an external device attached to set a userdefined LCD string. Floppy allows the USB flash drive to configure serial communication, external ...Integrated Devices PCI IRQ Assignment Serial Communication Embedded Server Management System Security
Keyboard NumLock (On default) Report Keyboard Errors (Report default)
Asset Tag
Description
Determines the ...
Hardware Owner's Manual (PDF) - Page 120
... attached peripherals.
See "Using Server Administrator Diagnostics" on page 131. 2 Turn on , only replace one fan at a time. 3 Locate the faulty fan indicated by the LCD display or diagnostic software.
Troubleshooting... close the system. If an error messages appears, go to the next step. See "Opening and Closing the System" on page 65. If an error message does not appear, continue ...
Hardware Owner's Manual (PDF) - Page 128
... 93. 5 Close the system. Troubleshooting the Microprocessors
Problem • Error message indicates a processor problem. • Front-panel status LCD indicates a problem with the processors or system board. • ...outlet, and turn on page 54.
128
Troubleshooting Your System
See "Using Server Administrator Diagnostics" on the system and attached peripherals. 13 Run the appropriate ...