Get support for Dell PowerEdge 1950

Dell PowerEdge 1950 Support Question

Dell PowerEdge 1950 Support Question

Find answers below for this question about Dell PowerEdge 1950.
Need a Dell PowerEdge 1950 manual? We have 7 online manuals for this item!
Question posted by supzp on July 5th, 2014

How To Clear Dell 1950 I1912 Sel Full

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by JCatDell on July 7th, 2014 8:26 AM
This answer was accepted by the poster of the original question.
JCatDell

Member since:
March 11th, 2014

Points: 136,220
1,110
points
Hi supzp,

There are a few ways to clear it. You can use openmanage server administrator and go to the logs tab. You can use the DSET tool to clear it http://www.dell.com/support/contents/us/en/19/article/Product-Support/Self-support-Knowledgebase/enterprise-resource-center/Enterprise-Tools/dell-system-e-support-tool

You can also clear it by going into ctrl+E during POST and going to system event logs and choosing clear.


Josh Craig

Dell | Social Outreach Services - Enterprise
Get Support on Twitter @DellCaresPro

Related Dell PowerEdge 1950 Manual Pages

Installing a SATA Optical Drive - Page 3

...the system cover. See "Opening the System" in your Hardware Owner's Manual. 4 PowerEdge 1950 systems only: Disconnect and remove the SAS controller daughter card. WARNING: Only trained service... outlet. 2 Remove the bezel. Installing a SATA Optical Drive These instructions apply to DellPowerEdge™ systems to remove the system cover and access any of the peripheral bay and...
Installing a SATA Optical Drive - Page 4

... the optical drive tray that shipped with the SATA drive installation kit. On PowerEdge 1950 systems, the existing optical drive tray must remove the old drive and interposer card... on the carrier fit into the tray and press the drive down to the optical drive. Replacing a PowerEdge 2950 or 2970 Optical Drive NOTE: If you are replacing an existing IDE optical drive, you are replacing...
Installing a SATA Optical Drive - Page 5

...power cable 7 optical drive carrier 2 interposer release latch 4 SATA cable 6 carrier latch Replacing a PowerEdge 1950 Optical Drive NOTE: The replacement drive tray provided in the side of the SATA optical drive into the... the carrier align with the holes in the installation kit must be used with PowerEdge 1950 systems. If you are replacing an existing optical drive, do not reuse the ...
Installing a SATA Optical Drive - Page 6

...the branching power cable to the power supply bays. a Route the cable through the power cable cutout in a PowerEdge 1950 Drive Tray 2 3 1 4 5 1 optical drive 3 SATA power cable 5 optical drive carrier 2 SATA ... the branching power cable) to the SATA_A connector on the system board. Figure 1-2. PowerEdge 1950 1 Insert the optical drive tray into the system until it is fully inserted and ...
Information Update - Page 1

DellPowerEdge1950 Systems Information Update
Information Update - Page 9

...core Intel Xeon processors. • If the front of memory is fully supported. PowerEdge 1950 III Systems PowerEdge 1950 III systems have added support for your system, verify that ships with a "III,"...restart the system. 8 Enter the System Setup program and verify that your system. See support.dell.com for information on your system. Support for 8-GB Memory Modules - For more than 4...
Information Update - Page 10

If you are using Windows Server® 2008, you are authorized to secure the contents of the components inside the computer... you replace the system board, you must supply the recovery key when you restart your Product Information Guide for the PowerEdge 1950 III system and the probable cause and corrective action when the message appears. System Message Update Table 1-1 lists new ...
Information Update - Page 15

... but with reduced functionality. Ensure that can occur on the PowerEdge 1950 III system and the probable cause for each message. The ..., see your systems management software documentation. For hard drive problems, see the system documentation on the SEL and configuring system management settings, see "Troubleshooting System Memory" in the Hardware Owner's Manual. Information Update...
Information Update - Page 25

...dell.com. Information Update 25 Operating System Information Enumeration of eth0, and NIC2 is supported by the PowerEdge 1950 and 1950 II systems, but not by the PowerEdge 1950 III system. RHEL - For information on the Server...Enterprise Linux® (version 4 or version 5) or SUSE® Linux Enterprise Server 9 or 10 operating systems, the NICs are enumerated in reverse: NIC1 is ...
Information Update - Page 49

... 4 或版本 5)或 SUSE® Linux Enterprise Server 9 或 10 NIC NIC1 eth1 eth0 ; NIC2 eth0 eth1 linux.dell.com 上的 Network Interface Card Naming RHEL RHEL 版本...® Windows® 2000 将位于 Server OS Install PowerEdge 19501950 II PowerEdge 1950 III 信息更新 49
Information Update - Page 137

...Hat® Enterprise Linux 4 5 SUSE® Linux Enterprise Server 9 または 10 NIC NIC1 が eth0 eth1 NIC2 が eth1 eth0 linux.dell.com Network Interface Card Naming RHEL • RHEL 4 5... Windows 2000 System Build and Update Utility Server OS Install OS OS Microsoft® Windows® 2000 PowerEdge 1950/1950 II OS PowerEdge 1950 III 137
Information Update - Page 162

...; eth0 linux.dell.com RHEL • Intel Xeon 54xx RHEL 버전 4 5 BIOS cat/proc/cpuinfo 및 cat/sys/devices/system/cpu/ cpuxx/cpufreq/scaling_cur_freq • Intel Xeon 54xx RHEL 버전 3 9 proc/cpuinfo RHEL 4 Update Microsoft Windows 2000 Microsoft® Windows® 2000 이 Server OS Install (서버 OS PowerEdge 1950 III...
Hardware Owner's Manual (PDF) - Page 2

...disclaims any manner whatsoever without notice. © 2009 Dell Inc. is subject to change without the written permission of Dell Inc.; Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, Dell OpenManage, and Dell XPS are trademarks of Dell Inc. All rights reserved. Other trademarks and trade...
Hardware Owner's Manual (PDF) - Page 18

...cleared using either missing, bad, or unable to recharge due to the AC power source, or the SEL is no longer fan- See your system's "Information Update Tech Sheet" located on support.dell... current system information. "Troubleshooting System Cooling heating. Specified microprocessor is either Server Assistant or the BMC Management Utility. If the problem persists, see "Getting...
Hardware Owner's Manual (PDF) - Page 24

...cable, and restart the system. LCD Status Messages (continued) Code Text Causes Corrective Actions I1912 SEL Full System Event Log is removed from the electrical outlet; Solving Problems Described by deleting ... and text on , the LCD message is recorded from the display: • Clear the SEL - Table 1-7. events. Removing LCD Status Messages For faults associated with sensors, such...
Hardware Owner's Manual (PDF) - Page 133

... and E-Mail Address Technical Support website: support.dell.com.cn Technical Support E-mail: cn_support@dell.com Customer Care E-mail: customer_cn@dell.com Technical Support Fax Technical Support (Dell™ Dimension™ and Inspiron) Technical Support (OptiPlex™, Latitude™, and Dell Precision™) Technical Support (servers and storage) Technical Support (projectors, PDAs...
Hardware Owner's Manual (PDF) - Page 136

... Service Switchboard Sales Fax General Support General Support General Support Website: support.ap.dell.com Technical Support E-mail: HK_support@Dell.com Technical Support (Dimension and Inspiron) Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (PowerApp™, PowerEdge™, PowerConnect™, and PowerVault™) Customer Care Large Corporate Accounts Global...
Hardware Owner's Manual (PDF) - Page 138

... Code: 44 Korea (Seoul) International Access Code: 001 Country Code: 82 City Code: 2 Department Name or Service Area, Website and E-Mail Address Website: support.jp.dell.com Technical Support (servers) Technical Support outside of Japan (servers) Technical Support (Dimension and Inspiron) Technical Support outside of Japan (Dimension and Inspiron) Technical Support...
Hardware Owner's Manual (PDF) - Page 142

... 005 Country Code: 65 Department Name or Service Area, Website and E-Mail Address Website: support.ap.dell.com Technical Support (Dimension, Inspiron, and Electronics and Accessories) Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) Customer Care Slovakia (Prague) International Access Code: 00 Country Code: 421 South...
Hardware Owner's Manual (PDF) - Page 144

... PowerVault) Customer Care Thailand International Access Code: 001 Country Code: 66 Transaction Sales Corporate Sales Website: support.ap.dell.com Technical Support (OptiPlex, Latitude, and Dell Precision) Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) Customer Care Trinidad/Tobago Turks and Caicos Islands Corporate Sales Transaction Sales General Support General Support...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 1950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.