Get support for Dell PowerEdge 1950

Dell PowerEdge 1950 Support Question

Dell PowerEdge 1950 Support Question

Find answers below for this question about Dell PowerEdge 1950.
Need a Dell PowerEdge 1950 manual? We have 7 online manuals for this item!
Question posted by Damammy6 on September 24th, 2013

Bios Cannot Detect Hard Drive Dell Poweredge 1950

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerEdge 1950 Manual Pages

Installing a SATA Optical Drive - Page 1

DellPowerEdge™ 19x0 and 29x0 Systems Installing a SATA Optical Drive
Installing a SATA Optical Drive - Page 3

...Owner's Manual. 4 PowerEdge 1950 systems only: Disconnect and remove the SAS controller daughter card. c Release the spring latch at the back of the tray and slide the drive tray out of the... SATA Optical Drive These instructions apply to DellPowerEdge™ systems to remove the system cover and access any of the components inside the system. Installing a SATA Optical Drive 3 WARNING:...
Installing a SATA Optical Drive - Page 4

... rotate the interposer board outward to detach the board from the drive carrier and install the new SATA drive in the side of the drive into the corresponding holes in the same carrier. On PowerEdge 1950 systems, the existing optical drive tray must remove the old drive and interposer card from the tray. 3 Pull outward again on...
Information Update - Page 1

DellPowerEdge1950 Systems Information Update
Information Update - Page 9

...dell.com for information on memory support requirements and restrictions, refer to the 5100 series of dual-core Intel Xeon processors and the 5300 series of quad-core Intel Xeon processors. • If the front of quad-core Intel Xeon processors. PowerEdge 1950 II and PowerEdge 1950... your system, verify that the USB key has been detected by the system. See "Using the System Setup Program...
Information Update - Page 10

... and access any of the hard drive. If you are using Windows Server® 2008, you are authorized to store this recovery key. System Board Replacement - System Message Update Table 1-1 lists new system messages for complete information about safety precautions, working inside the system. Safeguarding Encrypted Data On PowerEdge 1950 III systems using the TPM...
Information Update - Page 15

... configuring system management settings, see "Troubleshooting a Hard Drive" in a valid configuration. Ensure that can occur on selected drive Faulty USB device, USB medium, optical drive assembly, hard drive, or hard-drive subsystem. Replace the faulty media. Invalid memory ...Manual. Write fault Write fault on the PowerEdge 1950 III system and the probable cause for each message.
Information Update - Page 25

...and Demand-Based Switching is enabled in the BIOS, cat/proc/cpuinfo and cat/sys/devices/system/...Server OS Install tab. RHEL - Operating System Information Enumeration of eth1. System Support for Microsoft Windows 2000 If you run the System Build and Update Utility, Microsoft® Windows® 2000 is supported by the PowerEdge 1950 and 1950 II systems, but not by the PowerEdge 1950...
Information Update - Page 28

2006 - 2009 Dell Inc 未经 Dell Inc DellDELL 徽标和 PowerEdgeDell Inc Intel 和 Xeon 是 Intel Corporation Microsoft、Windows 和 Windows Server 是 Microsoft Corporation Red Hat 和 Red Hat Enterprise Linux 是 Red Hat, Inc SUSE 是 Novell Inc Dell Inc 2009 年 11 月 Rev. A09
Information Update - Page 49

...Intel Xeon 54xx BIOS cat/proc/cpuinfo 和 cat/sys/devices/system/cpu/cpuxx/cpufreq/scaling_ cur_freq RHEL 版本 3 更新 9 Intel Xeon 54xx proc/cpuinfo RHEL 4 Microsoft Windows 2000 System Build and Update Utility Microsoft® Windows® 2000 将位于 Server OS Install PowerEdge 19501950 II PowerEdge 1950 III 信...
Information Update - Page 137

... Xeon 54xx BIOS で Demand-Based Switching cat/proc/cpuinfo および cat/sys/devices/system/cpu/cpuxx/cpufreq/scaling_ cur_freq • RHEL 3 9 Intel Xeon 54xx proc/cpuinfo RHEL 4 Microsoft Windows 2000 System Build and Update Utility Server OS Install OS OS Microsoft® Windows® 2000 PowerEdge 1950/1950 II OS PowerEdge 1950 III 137
Information Update - Page 162

... eth0 linux.dell.com RHEL • Intel Xeon 54xx RHEL 버전 4 5 BIOS cat/proc/cpuinfo 및 cat/sys/devices/system/cpu/ cpuxx/cpufreq/scaling_cur_freq • Intel Xeon 54xx RHEL 버전 3 9 proc/cpuinfo RHEL 4 Update Microsoft Windows 2000 Microsoft® Windows® 2000 이 Server OS Install (서버 OS PowerEdge 1950 III 대...
Hardware Owner's Manual (PDF) - Page 21

... Controller Daughter Card" on page 102. Mem Config Err Memory detected, but not See "Troubleshooting System usable. See "Getting Help... hard drive has experienced a rebuild abort. See "Troubleshooting a Hard Drive" on setup and use of BMC. HDD ## Removed The specified hard drive ... in the system. Shadow BIOS Fail The system BIOS failed to the latest BMC firmware. CMOS ...
Hardware Owner's Manual (PDF) - Page 27

... device available Faulty or missing optical drive subsystem, hard drive, or hard-drive subsystem, or no boot disk in manufacturing mode. No action is in drive A. pressing the spacebar. on page 102. Manufacturing mode detected System is required. Reboot to take the appropriate action to carry This message is usually followed by BIOS: DIMM x Rank y Faulty memory module...
Hardware Owner's Manual (PDF) - Page 28

... x Causes Corrective Actions Incorrect configuration settings in Check the hard-drive configuration System Setup program, or no operating settings in the specified slot number. Expected Link Width is n Actual Link Width is detected during shadowing. PCIe Training Error: Slot n PCI BIOS failed to the expansion card(s). Loose cables to See "Troubleshooting System Memory" establish...
Hardware Owner's Manual (PDF) - Page 29

...sector on page 104 for the appropriate drive(s) installed in your Dell sales agent to determine if single-bit or multi-bit errors were detected and replace the faulty memory module....sector not found Seek error Seek operation failed Faulty diskette or hard drive. Dell recommends purchasing memory upgrade kits directly from www.dell.com or your system. Table 1-8. Ensure that only ECC ...
Hardware Owner's Manual (PDF) - Page 30

...SETUP program Timer chip counter 2 failed Unsupported CPU combination Unsupported CPU stepping detected Utility partition not available Causes Corrective Actions Incorrect Time or Date settings; ...Alert messages include information, status, warning, and failure messages for your the boot hard drive. If the problem persists, replace the system battery. See the CDs that ...
Hardware Owner's Manual (PDF) - Page 34

...Embedded Server Management Displays a screen to configure the front-panel LCD options and to act as a removal diskette drive. ...See support.dell.com for host systems that have installed a RAC, additional options, such as a hard drive. USB Flash Drive Type ... Redirection After Boot (Enabled default) Enables or disables BIOS console redirection after your system starts up with Console ...
Hardware Owner's Manual (PDF) - Page 104

... 2 Enter the System Setup program and ensure that is not authorized by Dell is not covered by the online or telephone service and support team. See...hard drive, and restart the system. 5 If your product documentation, or as applicable. For a problem with multiple hard drives, skip to enter the host adapter configuration utility program. 104 Troubleshooting Your System See "Using Server...
Hardware Owner's Manual (PDF) - Page 152

.... striping - Data stored in a series, you call Dell for the Windows operating environment. See RAM. A BIOS-based program that has two or more efficient use several ... Analysis and Reporting Technology. system board - Small computer system interface. Second(s). Allows hard drives to report errors and failures to remotely monitor and manage workstations. SVGA - Because the...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 1950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.